Power-Sonic Powerpure RT Series Manual de usuario

1/2/3 kVA
Thank you for purchasing the PowerPure RT series UPS.
The PowerPure RT series UPS is an intelligent, single phase in single phase out, high
frequency online UPS designed by our team of UPS experts. With excellent electrical
performance, advanced intelligent monitoring and network functions as well as complying
with EMC and safety standards, make the PowerPure RT series one of the leading UPS in
the industry.
Read this manual carefully before installation
This manual provides technical support to the operator of the equipment.

1
Table of Contents
1. Important Safety Warning..................................................................................................................2
1-1 Transportation ............................................................................................................................2
1-2 Preparation...................................................................................................................................2
1-3 Installation....................................................................................................................................2
1-4 Operation......................................................................................................................................3
1-5 Maintenance, service and faults...........................................................................................3
1-6 Symbols used in this guide.....................................................................................................4
2. Installation and setup...........................................................................................................................4
2-1 Unpack checking ........................................................................................................................4
2-2 Real panel view...........................................................................................................................5
2-3 Installing the UPS.......................................................................................................................6
2-4 UPS start up and turn off......................................................................................................15
2-5 Configuring Battery Setings ................................................................................................15
3. Operations..............................................................................................................................................20
3-1 Button operation......................................................................................................................20
3-2 Setup the UPS............................................................................................................................20
3-3 LCD display.................................................................................................................................22
3-4 UPS setting.................................................................................................................................24
3-5 Operational Status and Mode(s) ........................................................................................26
3-6 Alarm or Fault reference code.............................................................................................27
4. Troubleshooting ...................................................................................................................................27
5. Storage and Maintenance.................................................................................................................30
6. Options ....................................................................................................................................................30
7. Specification ..........................................................................................................................................32

2
1. Important Safety Warning
Important safety instructions –Save these instructions
Please comply with all warnings and operating instructions in this manual strictly.
Save this manual properly and read carefully the following instructions before
installing the unit. Do not operate this unit before reading through all safety
information and operating instructions carefully
There exists dangerous voltage and high temperature inside the UPS. During the
installation, operation and maintenance, please abide the local safety instructions
and relative laws, otherwise it will result in personnel injury or equipment damage.
Safety instructions in this manual act as a supplementary for the local safety
instructions. Our company will not assume the liability that caused by
disobeyingsafety instructions.
1-1 Transportation
Please transport the UPS system only in the original package to protect against
shock and impact.
1-2 Preparation
Condensation may occur if the UPS system is moved directly from cold to warm
environment. The UPS system must be absolutely dry before being installed.
Please allow at least two hours for the UPS system to acclimate the environment.
Do not install the UPS system near water or in moist environments.
Do not install the UPS system where it would be exposed to direct sunlight or
near heater.
Do not block ventilation holes in the UPS housing.
1-3 Installation
Do not connect appliances or devices which would overload the UPS system (e.g.
laser printers) to the UPS output sockets.
Place cables in such a way that no one can step on or trip over them.
Do not connect domestic appliances such as hair dryers to UPS output sockets.
The UPS can be operated by any individuals with no previous experience.
Connect the UPS system only to an earthed shockproof outlet which must be
easily accessible and close to the UPS system.
Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your
computer) to connect the UPS system to the building wiring outlet (shockproof
outlet).
Please use only VDE-tested, CE-marked power cables to connect the loads to the
UPS system.

3
When installing the equipment, it should ensure that the sum of the leakage
current of the UPS and the connected devices does not exceed 3.5mA.
1-4 Operation
Do not disconnect the mains cable on the UPS system or the building wiring
outlet (shockproof socket outlet) during operations since this would cancel the
protective earthing of the UPS system and of all connected loads.
The UPS system features its own, internal current source (batteries). The UPS
output sockets or output terminals block may be electrically live even if the UPS
system is not connected to the building wiring outlet.
In order to fully disconnect the UPS system, first press the OFF/Enter button to
disconnect the mains.
Prevent no fluids or other foreign objects from inside of the UPS system.
1-5 Maintenance, service and faults
The UPS system operates with hazardous voltages. Repairs may be carried out
only by qualified maintenance personnel.
Caution - risk of electric shock. Even after the unit is disconnected from the
mains (building wiring outlet), components inside the UPS system are still
connected to the battery and electrically live and dangerous.
Before carrying out any kind of service and/or maintenance, disconnect the
batteries and verify that no current is present and no hazardous voltage exists in
the terminals of high capability capacitor such as BUS-capacitors.
Only persons are adequately familiar with batteries and with the required
precautionary measures may replace batteries and supervise operations.
Unauthorized persons must be kept well away from the batteries.
Caution - risk of electric shock. The battery circuit is not isolated from the input
voltage. Hazardous voltages may occur between the battery terminals and the
ground. Before touching, please verify that no voltage is present!
Batteries may cause electric shock and have a high short-circuit current. Please
take the precautionary measures specified below and any other measures
necessary when working with batteries:
-remove wristwatches, rings and other metal objects
-use only tools with insulated grips and handles.
When changing batteries, install the same number and same type of batteries.
Do not attempt to dispose of batteries by burning them. This could cause battery
explosion.
Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin
and eyes. It may be toxic.

4
Please replace the fuse only with the same type and amperage in order to avoid
fire hazards.
Do not dismantle the UPS system.
1-6 Symbols used in this guide
WARNING!
Riskofelectricshock
CAUTION!
Readthisinformationtoavoidequipmentdamage
2. Installationand setup
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the
package is damaged. Please keep the original package in a safe place for future use.
2-1 Unpack checking
Don’t lean the UPS when moving it out from the packaging.
Check the appearance to see if the UPS is damaged or not during the
transportation, do not switch on the UPS if any damage found. Please contact the
dealer right away.
Check the accessories according to the packing list and contact the dealer in case
of missing parts.
It includes:
(1) UPS user's guide
(2) Installationcard
(3) USB cable
(4) Power cord (Input and output)
(5) RS232 cable

5
2-2 Real panel view
1KVA(S/H):
2KVA(S/H):
3KVA(S/H):
1. Output receptacles(10A)
2. Battery Terminal

6
3. SNMP intelligent slot
4. Network /Fax/Modem Surge Protection
5. RS-232 communication port
6. AC inputreceptacle
7. Input circuit breaker
8. EPO
9. USB
10. Output receptacle(16A)
2-3 Installing the UPS
Rackmount installation
The Rackmount cabinet comes with all of the hardware required for installation
in a standard EIA or JIS seismic Rackmount configuration with square and round
mounting holes. The rail assemblies adjust to mount in 19” racks with a distance
from front to rear around 70~76 cm (27 to 30 inches) deep.
CAUTION
The cabinet is heavy. Removing the cabinet from its carton
requires a minimum of two people.
If installing optional EBP(S), make sure to install the EBP(S)
directlybelow the UPS so that all wiring between the cabinets is
installed behind the front covers and inaccessible to users.
NOTE
Mounting rails are required for each individual cabinet
(1)To install the rail kit
a) Assemble the left and right rails to the rear rails as shown in Figure1.Do not tighten
the screws.
Adjust each rail size for the depth of your rack.
Figure1Securing the Rails

7
b) Select the proper size in the rack for positioning the UPS (see Figure 2). The
railoccupies four positions on the front and rear of the rack.
c) Tighten four M5 Umbrella Nuts in the side of rail assembly(see Figure 1).
d) Fix one rail assembly to the front of the rack with one M5×12 pan-head screw and
one M5 cage nut. Using two M5 cage nuts and two M5×12 pan-head screws, to fix
the rail assembly to the rear of the rack.
Figure2 Fixing the Rails
e) Repeat Steps 3 and 4 for the other rail assembly.
f) Tighten the four butterfly nuts in the middle of each rail assembly.
g) If installing optional cabinets, repeat Step 1 through Step 6 for each rail kit.
h) Place the UPS on a flat, stable surface with the front of the cabinet facing to you.
i) Align the mounting brackets with the screw holes on each side of the UPS and fix
with the supplied M4×8 flat-head screws(see Figure 3)
Figure3Installing the Mounting Brackets
j) If installing optional cabinets, repeat Step 8 and 9 for each cabinet.
k) Slide the UPS and any other optional cabinets into the rack.
l) Secure the front of the UPS to the rack using one M5×12 pan-head screws and one
M5 cage nuts on each side(see Figure 4).Install the bottom screw on each side
through the bottom hole of mounting bracket and the bottom hole of the rail.
Repeat for any optional cabinets.

8
Figure4 Securing the Front of the Cabinet
m) Continue to the following section, “Rackmount Wiring Installation.
(2)Rackmount Wiring Installation
a) Installing the UPS, including connecting the UPS internal batteries
b) Connecting any Optional EBP(S)
To install the UPS
NOTEDo not make unauthorized changes to the ups; otherwise, damage may
occur to your equipment and void your warranty.
NOTE
Do not connect the ups power cord to utility until after
installation is completed.
a) Remove the front cover of each UPS
Press the cover side with LCD display, hold the other side and quickly extract it, then
extract the other side with display. (see Fig.5)
NOTE A ribbon cable connects the LCD control cover to the UPS. Do not pull on the
cable or disconnect it.
When remove the cover, Operate as the following right Figure shows instead of the left
one. (see Fig.5)

9
Figure5Extract UPS front cover
CAUTION
A small amount of arcing may occur when connecting the internal batteries. This is
normal and will not harm personnel. Connect the cables quickly and firmly
b) Connect the internal battery connector(see Figure6)
Connect red to red, Press the connector tightly together to ensure a proper connection.
c) If you are installing EBPS,see the following section, “Connectingthe EBP(s),”
before continuing with the UPS installation.
Figure6Connecting the UPS Internal Batteries
d) Replace the UPS front cover.
To replace the cover, verify that the ribbon cable is protected and (ifEBPS are installed)
the EBP cable is routed through the knockouton the bottom of the cover.
Put the front cover hooks of side with display to the cover port, put another side to the
other two ports, then press it until the cover and the chassis are combined tightly.
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Manuales populares de Unión Postal Universal de otras marcas

Pylontech
Pylontech Victron & Pylontech US5000 Manual de usuario

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manual de usuario

Mecer
Mecer ME-1000-WTU Manual de usuario

Mustek
Mustek PowerMust 530(B) Plus Manual de instalación y operación

Emerson
Emerson Liebert NXL series Manual de usuario

MAKELSAN
MAKELSAN BOXER SERIES Manual de usuario