PNI SafeHome PTY500BL Manual de usuario

PNI SafeHome PTY500BL
PNI SafeHome PTY500BR
Smart lock / Yala inteligenta
EN User manual ............................................. 3
RO Manual de utilizare ................................... 17


3User manual
English
Information and warnings
• Prepare a Phillips screwdriver and 4 AA batteries before installing the
lock.
• Before installing the lock, make sure you have clean hands so as
not to stain its surface. Do not use detergents, alcohol or corrosive
substances to clean the surface of the lock. Use only a soft cloth
slightly moistened with water.
• With the basic settings, the lock can be opened by any ngerprint,
card or by password 1234567890 #. If none of the opening methods
work, use the mechanical key to unlock the lock.
• Install 4 fully charged AA batteries. If the voltage is not sucient
(<4.8V), the lock will emit a warning sound. Replace the batteries with
new ones.
• The lock is recommended for doors with a thickness between 40 and
100 mm.
Main features
• The total capacity of the system is 300 users and 100 ngerprints (of
which, the rst 3 are as administrators).
• The system supports passwords of 6-8 characters and 20 virtual
passwords (generated by the application).
• The system warns in case of low voltage.
Fingerprint sensor Semi-conductor
DPI 500
Identication time 0.3 sec.
Unlock methods Fingerprint, Card, Password,
Mechanical key and Application
Supply voltage 6V
Low voltage warning level 4.8V
Standby current ≤50µA

User manual 4
English
Description of lock components
1. Front panel
2. Connection column
3. Square steel
4. Lock body
5. Connection Line
6. Back panel
7. SET button (add administrators / users, pairing, reset)
8. Connection column screws
9. Battery cover
10. Battery cover screw
11. Back handle
12. Connection column screws
13. Reverse lock knob
14. Back locking paddle
15. Latch-bolt
16. Lock body screws

5User manual
English
17. Connection column
18. Key hole
19. Micro USB port (emergency power port)
20. Front handle
Included accessories
Square steel
(8 cm, 10 cm, 12 cm)
Connection column
(3.5 cm, 5.5 cm)
Connection column
screws
(3 cm, 5 cm, 7 cm, 9 cm)
Dimensions
275 mm
70 mm
137 mm
30 mm
45 mm

User manual 6
English
Door opening direction
Indoor
Right hand door
Left hand door
Indoor
Outdoor
Outdoor
Indoor
Indoor
Outdoor
Outdoor
WARNINGS:
• We recommend that you contact qualied personnel to install the lock.
• Read all instructions carefully before installing the lock.
• Be careful not to press or bend the connection cables during
installation.
• Before choosing the type of lock and before installing it, pay attention
to the opening direction of the door (left or right).
• During the installation of the lock, the door must be half opened.
• After installing the lock, rst test the password unlock method (default
1234567890 #) and the mechanical key. Test the opening of the lock
on both sides of the door. If the lock does not unlock with any of the
above methods, check the cable connection.
Opening the lock with the mechanical key
1. When the lock is locked, insert the mechanical key into the hole in the
bottom of the outer body of the it.
2. Turn the key.
3. Pull the lock handle up.
4. The lock will unlock.
5. Open the door.

7User manual
English
Installation instructions
1. Use the model included in the package to mark and make the holes
needed to mount the lock.
2. Install the lock body rst. Secure it with the included screws.
Note: the package includes several mounting accessories that must
be chosen depending on the thickness of the door on which the lock is
installed. Refer to the table below to choose the right accessories for your
door.
Door thickness Square steel
length
Connection
column length
Length of
connection
column screws
4.0 - 5.5 cm 8 cm 3.5 cm 3 cm and 5 cm
5.5 - 6 cm 8 cm 5.5 cm 3 cm and 5 cm
7.0 - 8.0 cm 10 cm 5.5 cm 5 cm and 7 cm
9.0 - 10 cm 12 cm 5.5 cm 7 cm and 9 cm
3. Install the two bodies of the lock:
Install the outer body of the lock
rstly:
• Screw two screws onto the
back of the outer body of
the lock. Choose the screws
according to the thickness of
your door. Please refer to the
table above.

User manual 8
English
Door • Insert the square steel into the
hole on the back of the outer
body of the lock.
• Pass the connection cables
through the hole previously
made in the door.
• Pass the square steel through
the door and through the lock.
• Push the body of the lock until it
approaches the door.
Connection column - Hole for screws
Unlocking paddle
Hole for
square steel
Door
Install the inner body of the lock
• Insert the connector on the
connecting cables coming from
the outer body of the lock into
the socket on the back of the
inner body of the lock.
• Insert the locking paddle into
the dedicated hole on the lock.
You can shorten the locking
paddle depending on the
thickness of the door.
• Insert the square steel into the
dedicated hole on the inner
body of the lock. Push the body
of the lock until it approaches
the door.
• Align the connection columns
(which were previously screwed
onto the outer body of the lock)
with the holes on the inner body
of the lock. Now fasten the two
body of the door lock, screwing
the two screws included in the
package. Refer to the table
above for the correct choice
of screws depending on the
thickness of the door.

9User manual
English
4. Install the buckle plate and buckle box
Door frame
Screw
Screw
Buckle box
Usage instructions
Add Administrator:
1. Remove the cover from the battery compartment.
2. Briey press the SET button or long press the * key on the keyboard.
You will hear the message “Please add administrator“.
3. Register the Administrator with a ngerprint (the ngerprint must
be scanned 3 times), with a card or password (the password must
contain 6-8 digits followed by # and must be entered 2 times for
registration).
4. You will hear the message “Add successfully”.
5. You can stop at one administrator or you can continue to add two

User manual 10
English
more administrators.
Notes:
Press * key: for back and log out
Press # key: for conrmation
Add User:
1. Remove the cover from the battery compartment.
2. Briey press the SET button or long press the *key on the keyboard.
You will hear the message “Please verify the administrator”.
3. Enter the administrator verication data (depending on the method
you registered with: ngerprint, card, password)
4. Register the User with a ngerprint (the ngerprint must be scanned
3 times), with a card or with a password (the password must contain
6-8 digits followed by #and must be entered 2 times for registration).
5. You will hear the message “Add successfully”.
6. You can continue to add users.
Delete User:
1. Remove the cover from the battery compartment.
2. Briey press the SET button or long press the * key on the keyboard.
You will hear the message “Please verify the administrator”.
3. Enter the administrator verication data (depending on the method
you registered with: ngerprint, card, password).
4. Briey press the SET button again or press and hold *
5. Press key 1 - to delete all user ngerprints; Press the 2 key - to delete
all user passwords; Press the 3 key - to delete all user cards; Press
the 4 - key to delete all users (Note: The administrator will not be
deleted).
6. You will hear the message “Successful”.
Reset the lock:
1. Remove the cover from the battery compartment.
2. Remove a battery.
3. Keep pressing the Reset button while inserting the battery in its place.
4. Input the Master password 075526929133#
5. The system will return to the factory settings. The default Administrator
password will become 1234567890 #.
6. After resetting, add an Administrator immediately.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Cerradura de puerta de PNI