Planmeca ProSensor HD Manual de usuario

Planmeca ProSensor®HD
for veterinary use
user's manual
EN
30028714

The manufacturer, assembler and importer are responsible for the safety, reliability and
performance of the unit only if:
- installation, calibration, modification and repairs are carried out by qualified
authorised personnel
- electrical installations are carried out according to the appropriate requirements such
as IEC 60364
- equipment is used according to the operating instructions.
Planmeca pursues a policy of continual product development. Although every effort is
made to produce up-to-date product documentation this publication should not be
regarded as an infallible guide to current specifications. We reserve the right to make
changes without prior notice.
COPYRIGHT PLANMECA
Publication number 30028714 Revision 1
Released 09 October 2020

Table of contents
1 Introduction.................................................................................................................................................1
2 Associated documentation..........................................................................................................................1
3 Registering your sensor system................................................................................................................. 2
4 Symbols......................................................................................................................................................3
5 Safety precautions......................................................................................................................................4
6 ControlBox indicator light............................................................................................................................5
7 Before exposure......................................................................................................................................... 6
7.1 Sensor positioning..........................................................................................................................6
7.2 Selecting exposure values..............................................................................................................8
7.2.1 Recommended exposure values for cats or smaller animals.........................................8
7.2.2 Recommended exposure values for larger animals.......................................................9
8 Capturing intraoral images........................................................................................................................11
8.1 Capturing single intraoral images.................................................................................................11
8.2 Capturing images into study template.......................................................................................... 12
9 Planmeca ProSensor HD in Planmeca Romexis Clinic Management module......................................... 15
10 Image quality control.................................................................................................................................16
10.1 Quality check using SMPTE test pattern......................................................................................16
11 Cleaning and disinfection..........................................................................................................................17
11.1 Sensors and cables......................................................................................................................17
11.2 Planmeca ProSensor ControlBox.................................................................................................18
12 Disposal....................................................................................................................................................19
13 Technical specifications............................................................................................................................20
13.1 Sensor.......................................................................................................................................... 20
13.2 Ethernet ControlBox..................................................................................................................... 20
13.3 USB ControlBox........................................................................................................................... 21
13.4 Supported operating systems.......................................................................................................21
13.5 Operating environment.................................................................................................................21
13.6 Transportation and storage environment......................................................................................21
14 Exposure value tables for Planmeca ProX............................................................................................... 23
14.1 Default exposure values...............................................................................................................23
14.2 Recommended exposure values for animals with Planmeca ProX..............................................23
User's manual Planmeca ProSensor® HD

Table of contents
Planmeca ProSensor® HD User's manual

1 Introduction
This manual describes how to use and install the Planmeca ProSensor HD
sensor that is intended to be used for capturing digital intraoral X-ray images
from patient’s jaw, teeth, gums, roots and root canals by trained dental care
professionals.
Please read this manual carefully before using the system.
Planmeca ProSensor automatically triggers and captures images to the start
and end of the x-ray radiation so that any intraoral x-ray unit supporting
exposure times and cones listed In chapter "Selecting exposure values" on
page 8 can be used.
The Planmeca Romexis imaging software or third party software stating
compatibility with Planmeca ProSensor or software stating compatibility
through TWAIN can be used for image capturing.
Planmeca ProSensor is connected to a computer using Ethernet or USB
interface and it supports Windows and MAC operating systems, see details
in section "Technical specifications" on page 20.
This manual is valid for following software versions:
• Planmeca ProSensor Ethernet software version 2.5.0.R or later
• Planmeca ProSensor USB software version 2.5.1.R or later
• Didapi software version 5.3.3.R or later. The high resolution option for
size 0 sensor requires version 5.5.1.R or later.
2 Associated documentation
This manual should be used in conjunction with following manuals:
• Planmeca ProX for veterinary use user's manual
• Planmeca ProX installation manual
• Planmeca ProX technical manual
• Planmeca ProSensor HD installation manual
• Planmeca ProSensor HD technical manual
These manuals are intended to be used in conjunction with the
documentation for the Planmeca Romexis imaging software. The imaging
software package contains the following manuals:
• Planmeca Romexis user’s manual
• Planmeca Romexis technical manual
1 Introduction
User's manual Planmeca ProSensor® HD 1

3 Registering your sensor system
Before you start using your Planmeca ProSensor system, you must
register it to activate the warranty.
To register:
Read the QR code on the package box with a QR code reader to
enter the registration website.
OR
Navigate to the registration website www.planmeca.com/register/ in
your Internet browser.
Follow the instructions on the website.
1 Registering your sensor system
2 Planmeca ProSensor® HD User's manual

4 Symbols
Type BF equipment (Standard IEC 60601-1).
Attention, consult accompanying documents (Standard IEC 60601-1).
The use of accessory equipment not complying with the equivalent
requirements of this equipment may lead to a reduced level of safety of the
resulting system. Consideration relating to the choice shall include:
• use of the accessory in the Patient Vicinity
• evidence that the safety certification of the accessory has been
performed in accordance to appropriate IEC60601 and/or IEC60601-1-1
harmonized national standard.
Planmeca ProSensor is ETL classified and conforms to ANSI/AAMI
ES60601-1 and is certified to CAN/CSA C22.2 No. 60601.1:08.
Separate collection for electrical and electronic equipment according to
Directive 2002/96/EC (WEEE)
3143029
ETL CLASSIFIED
4 Symbols
User's manual Planmeca ProSensor® HD 3

5 Safety precautions
NOTE
The system should be operated by qualified personnel only.
NOTE
EMC requirements have to be considered, and the equipment must be
installed and put into service according to the specific EMC information
provided in the accompanying documents.
CAUTION
Handle the Planmeca ProSensor according to the instructions given in this
manual. Do not pinch the sensor or the cable. Do not to drop the sensor or
pull strongly the sensor cable. Never cut, nick or sharply bend the sensor
cable. Always advise the patient not to bite the sensor or the cable. The
Planmeca limited warranty does not cover damage which is due to misuse,
e.g. dropping the sensor, neglect, or any cause other than ordinary
application.
CAUTION
Do not let the sensor cable run along the floor. Protect the cable from rolling
over it with a chair or walking over it.
CAUTION
Do not store or use the Planmeca ProSensor near (3m or 10 ft) an
electrosurgical knife.
CAUTION
Do not unnecessarily touch the connector pins to keep them clean.
WARNING
No modification of this dental unit is allowed.
5 Safety precautions
4 Planmeca ProSensor® HD User's manual

6 ControlBox indicator light
Planmeca ProSensor ControlBox indicator light explanation
CONTROLBOX INDICATOR LIGHT PLANMECA PROSENSOR STATUS
Off Planmeca ProSensor system power off
Dim blue Planmeca ProSensor system is off (not in
intraoral exposure-mode and the cable is
connected to the ControlBox)
Bright blue Planmeca ProSensor system is on (Imaging
program communicates with the Planmeca
ProSensor system)
Slowly flashing blue Waiting for Ready
Steady green Waiting for Exposure
Rapidly flashing green The exposure is taken and image is transferred
from the sensor to the ControlBox
Steady red Error mode
Slowly flashing yellow Service mode
Uploading ControlBox software
Slowly flashing blue, turns to slowly flashing dim
blue, then to quickly flashing dim blue
Reading calibration files from the sensor
Flashing violet ControlBox startup with back-up software
Flashing white Sensor is being calibrated
Purple light at beginning when powering up the
control box
Control box is running a factory software
NOTE
The exposure can only be taken when the Planmeca ProSensor ControlBox
indicator light is green and steady, not when the indicator light is flashing.
6 ControlBox indicator light
User's manual Planmeca ProSensor® HD 5

7 Before exposure
NOTE
Detailed instructions for using Planmeca ProX X-ray unit and Planmeca
Romexis software are given in their User’s manual, which should be used in
conjunction with this manual.
NOTE
In case the environment temperature reaches 40°C the sensor surface
warms up to its maximum temperature of 46°C and may feel warm. The
surface temperature of the sensor cools off when in patient contact.
Before each use on a patient make sure the sensor has been appropriately
disinfected. For detailed cleaning instructions see section "Sensors and
cables" on page 17.
To avoid cross-contamination between patients during use, disposable
hygienic sheaths must be used.
NOTE
Always use a new disposable hygienic sheath for every sensor usage.
When using the sensor for the first time the message
Loading calibration
files
will appear on the Romexis window.
NOTE
When connecting the same sensor to another workstation the calibration
files will be reloaded.
Select the appropriate sensor and connect it to the Planmeca ProSensor
ControlBox.
7.1 Sensor positioning
Bisecting angle technique
The bisecting angle technique is the most commonly used technique in
veterinary imaging for its accurate representation of the tooth and roots.
7 Before exposure
6 Planmeca ProSensor® HD User's manual
Tabla de contenidos
Otros manuales de Producto para el cuidado de mascotas de Planmeca
Manuales populares de Producto para el cuidado de mascotas de otras marcas

ubbink
ubbink KoiFeeder Solar Manual de usuario

ULTRACOM
ULTRACOM KOIRA-GPS Manual de usuario

CADOCA
CADOCA Deuba 106911 Manual de usuario

Dogtra
Dogtra RR Deluxe Manual de usuario

Carson
Carson CONVERTIBLE PET YARD 2200 Manual de usuario

Creative Cedar Designs
Creative Cedar Designs K-9 Kabin Manual de usuario












