Things you must know
1. Introduction
2. System overview
3. Installing the
Phenom
4. Using the Phenom
CONTENTS
Things you must know 6
Introduction 8
1.1 Unpacking the Phenom components 8
1.2 Packaging contents 9
System overview 10
Controls 10
Connections 12
Screens 13
Installing the Phenom 18
Preparation 18
3.1 Requirements for positioning the Phenom components 18
3.2 Assembling the flat panel touch screen monitor 18
Connections 19
3.3 Connecting the Phenom 19
3.4 Activating the system 21
3.4.1 Switching on the Phenom 21
3.4.2 Switching ‘on’ the flat panel touch screen monitor 21
3.4.3 Calibrating the flat panel touch screen monitor 21
Using the Phenom 22
Preparation 22
4.1 Waking-up the Phenom 22
4.2 Preparing samples 22
4.2.1 Samples that cannot be prepared in colloidal graphite or silver paint 23
4.2.2 Particle samples 23
4.2.3 Polymers 24
4.2.4 Metals 24
4.2.5 Biological samples 24
4.2.6 Heavy metal coating 25
4.3 Loading samples 25
4.3.1 Activating the sample holder 26
Operation 26
4.4 Using the touch screen 27
4.5 Optical imaging 27
4.5.1 Adjusting focus 27
4.5.2 Adjusting brightness and contrast 27
4.5.3 Adjusting magnification (ProX / Pro) 28
4.5.4 Moving the sample 28
4.5.5 Sample overview 28
4.5.6 Storing images 28
4.6 lectron imaging 30
4.6.1 Adjusting focus 30
4.6.2 Adjusting brightness and contrast 31
4.6.3 Magnifying the image 31
4.6.4 Rotating the image 31
4.6.5 Moving the sample 32
4.6.6 Storing images 32
4.7 Viewing stored images 33
4.7.1 Comparing images (ProX / Pro) 34
4.7.2 Deleting stored images 34
4.8 Measuring on stored images (ProX / Pro) 35
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 3

4
4.9 Unloading the sample 35
4.10 Switching off the Phenom electron source 36
4.10.1 Switching off the Phenom 36
4.10.2 Switching off the flat panel touch screen monitor 37
4.10.3 Switching off the system completely 37
Phenom settings 37
75.1 Live viewing settings 37
5.1.1 Mode 37
5.1.2 Resolution 37
5.1.3 Quality 38
5.1.4 Intensity 38
5.2 Acquired image settings 38
5.2.1 Detector mode 38
5.2.2 Quality 39
5.2.3 Resolution 39
5.2.4 Presets 39
5.2.5 Storing user settings 40
5.3 Date and time 40
5.3.1 Adjusting the date 40
5.3.2 Adjusting the time 40
5.4 Databar / image type / UI mode 40
5.4.1 Databar 40
5.4.2 Image type 40
5.4.3 UI mode 41
5.5 Label 41
5.6 USB stick / Mode 41
5.6.1 USB stick 41
5.6.2 Mode 41
5.7 Advanced settings 42
5.7.1 SW (software) version 42
5.7.2 Shutdown 42
5.7.3 StoreSys(tem)Info 43
5.7.4 Routine pages 43
5.7.4.1 Source Tilt 43
5.7.4.2 Stigmate 44
5.7.4.3 Network 45
5.7.4.4 Connectivity 46
Maintenance 48
Troubleshooting 49
7.1 rror recovery and reporting 53
7.1.1 Rotary knob state indicator 53
7.1.2 rror messages and warnings 53
7.2 Power down 55
7.3 Rebooting the Phenom software 55
Preparing the Phenom for transport 56
8.1 Return procedure 56
8.2 Prepare for packing 56
8.3 Disconnecting and packing 57
Technical specifications 58
5. Phenom settings
6. Maintenance
7. Troubleshooting
8.
Preparing the
Phenom for
transport
9.
Technical
specifications
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 4

5
Phenom-World and the Phenom-World logo are registered trademarks of
Phenom-World Bv. PhenomTM is a trademark of Phenom-World BV.
Other product and company names mentioned herein may be the trademarks of their
respective owners.
This user guide was produced using XPress®document publishing software, a registered
trademark of Quark Technology and the ArialTM family of typefaces. Arial is a trademark of
The Monotype Corporation registered in the U.S. Patent & Trademark Office and may be
registered in other jurisdictions.
Ralph Schiedon
Joris Dobbelsteen
Sander Stoks
Jeroen Smulders
Karl Kersten
Koen Driessen
Karel van der Mast
Addo Hammen
Willem Theuws
Rob Rood (ROOD Text productions)
Copyright ©2013 by Phenom-World BV
The information and materials contained herein are confidential and proprietary to
Phenom-World BV. They are provided for your organization’s internal use on a need to
know basis. They cannot be duplicated or disseminated for any third party without the
express consent of Phenom-World BV.
The information contained in this document has been composed with great care for quality,
reliabilty and accuracy and may be changed without notice.
Phenom-World BV will not accept liability for any consequence of use of this document.
Trademark
Acknowledgments
Production
Acknowledgments
Principal Contributors
Technical Publication
Disclaimer
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 5

6
CAUTION!
General Safety
Important information
To avoid Fire or
Personal Injury
Things you must know
PleasereadalloftheseinstructionsbeforeyouoperatethePhenom.
Savetheseinstructionsforfuturereference.
Review the following safety precautions to avoid injury and prevent damage to the
Phenom microscope.
All safety and operating instructions must be read before the
microscope is operated, this is to avoid personal injury and prevent damage to the
Phenom.
To avoid potential hazards, use this product only as specified.
The user must not attempt to service the appliance beyond those means described in
the user's operating instructions.
All other servicing is to be performed by qualified service personnel.
Replace Fuse with identical type.
If a fuse is replaced, use the type as mentioned on the type plate.
Ground the Microscope.
The microscope is grounded through the grounding conductor of the power cord.
To avoid electrical shock the grounding conductor must be connected to earth ground.
Before using the microscope verify that the microscope is properly grounded.
Use correct power cord.
Only use the power cord specified for this product and approved for the country of
use.
Power Disconnect.
The power switch on the mains supply disconnects the microscope from the mains.
Do not block the power switch; it must be accessible to the user at all times.
Do not operate without covers.
The microscope must never be operated with the cover removed.
Do not operate the microscope with suspected failures or damaged covers.
If you suspect damage or failure of the product, do not disassemble this product.
Have it serviced by qualified and authorized service personnel. Servicing is required
when the microscope is damaged in any way, such as when the power supply cord or
the plug is damaged, liquid has been spilled in the microscope, it does not operate
normally or has been dropped.
Provide proper ventilation.
Adequate airflow must be allowed around the power supply and Phenom microscope
.
Do not block the ventilation openings. Respect at least 20 cm of free space to the
sides, the front, the back and the top of the Phenom microscope. Do not put materials
in the air gap between the Phenom microscope and the table.
Do not operate in wet and damp conditions.
The required room temperature and maximum humidity as specified in the system's
technical specifications (see chapter 9, ‘Technical specifications’) must be respected
at all times.
Do not operate in an explosive atmosphere.
Make sure that there is proper room ventilation such that the environmental air cannot
contain combustible gasses.
Do not use compressed-gas canisters in the vicinity of the system.
Propellants of canisters are very often combustible.
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 6

7
Environmental
aspects
Notes!
Equipment recycling
To reduce the use of natural resources and to avoid the release of substances that
could be harmful to the environment or human health we advise you to recycle this
product.
For information about recycling options please contact Phenom-World’s Customer
Support.
Disposal of your old product
Your product is designed and manufactured with high quality materials and
components, which can be recycled and reused.
When this crossed-out wheeled bin symbol is attached to a product it means the
product is covered by the uropean Directive 2002/96/ C.
Please act according to your local rules and do not dispose of your old products with
your normal household waste. The correct disposal of your old product will help
prevent potential negative consequences for the environment and human health.
Equipment classification
The Phenom should be used indoor in a controlled electromagnetic environment.
The Phenom electron microscope is C compliant with the following directives:
– 73/023/ C Low Voltage Directive
– 89/336/ C lectromagnetic Compatibility Directive
– 96/29/ URATOM Ionizing Radiation Directive following article 3.2 e.
Using the following standards:
N61010-1 Safety measurements for electrical equipment for measurement, control and
laboratory use.
N61326-1 lectrical equipment for measurement, control and laboratory use – MC
requirements (industrial level) and that the X-ray emission is below 1 µSv/h at 10 cm
distance from the surface
Phenom microscopes are classified as:
• Safety class 1 ( N 61010-1)
• Pollution class 2 ( N 61010-1)
• Installation (Overvoltage) category 2 ( N 61010-1)
• Plug connected
– MC lectroMagnetic Compatibility
– Licensing or registration for X-ray might be required according to local regulations.
For most of urope no licensing or registration is necessary (see 96 / 29 / uratom
directive, para. 3.2.e).
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 7

8
Preparation
Unpacking
Caution!
1. Introduction
Congratulations on your purchase of the PhenomTM microscope. The PhenomTM is a high
resolution desktop imaging tool that combines an optical camera for never-lost navigation
and a high quality scanning electron microscope (S M) for detailed imaging to bring a
completely new approach to microscopy.
The Phenom’s innovative user interface utilizes intuitive touch screen controls which allows
users to observe superb quality images with minimal operator training.
The Phenom can handle a wide range of samples with minimal preparation.
We are sure that if used properly, the Phenom will bring you years of enjoyment.
You will want to keep this user manual handy, as it is a convenient source of information
about the Phenom.
1.1 Unpacking the Phenom components
Make sure the room where the Phenom components are to be placed is clean and dry
and that room temperature is between 15 °C and 30°C (59 °F and 86°F).
Room humidity should not exceed 80% RH.
Avoid direct sunlight, vibrations and strong magnetic fields.
Also refer to chapter 3.1 ‘Requirements for positioning the Phenom components’.
1First inspect the packaging before opening it. If the packaging is damaged or if the
locks are open, we recommend that you report this to Phenom-World’s Customer
Support:
- address: Dillenburgstraat 9
5652 AM indhoven
The Netherlands
- e-mail: [email protected]
- phone: +31 (0)40 259 73 72
- fax: +31 (0)40 259 73 71
- opening hours: Monday - Friday, 09:00 - 17:00 (C T, GMT +1)
It is however very likely that, despite slight damage to the packaging, the Phenom
components are still in good condition.
2Open all 4 locks and open the top cover completely.
3Remove the front panel by lifting it upwards.
4Remove all loose foam parts.
5Lower the plastic bag and remove the Phenom microscope.
Due to the weight, it is recommended that two people, one on each side, lift the
Phenom out of the box. Donot lift from the front as the door could easily be
damaged. Donot lift by the plexiglass frontcap or by the door handle.
6Confirm that all Phenom components are present. For a complete list of components,
refer to chapter 1.2 ‘Packaging contents’.
7Take the boxes out of the other compartment.
8Unpack all accessories prior to installation.
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 8

9
1.2 Packaging contents
Please verify that the Phenom box contains the following items. They are provided to help
you set up and use the Phenom. If any of these items are missing or damaged, contact your
dealer immediately.
Save the packaging materials in case you need to transport the Phenom.
Phenom microscope ProX / Pro / Pure - 17"flat panel touch screen monitor (Pure)
- 19"flat panel touch screen monitor (ProX / Pro)
Flat panel touch screen Pre-vacuum pump Power supply
monitor VGA cable
Rotary knob Rotary knob Sample holder
extension cable
USB Flash drive Pre-vacuum pumphose - Power cable Europe 2 x
- Power cable US 2 x
Mouse (ProX / Pro) Phenom Starter it User manual
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 9

Controls
Phenom microscope
Mouse
(Pro)
Rotary knob
USB Flash drive
2. System overview
1ySystem control button
- Switches the Phenom from standby or hibernate mode to operation mode.
- Switches the Phenom from operation mode to standby.
POWER
- Blinks green when the Phenom power supply is switched on and the Phenom goes
to operation mode.
- Blinks green when the Phenom switches from standby or hibernate mode to
operation mode.
- Lights up orange in standby mode.
- Blinks orange (1 second on, 3 seconds off) in hibernate mode.
- Lights up green in operation mode.
2 SAMPLE (sample indicator)
Lights up green when a sample is loaded.
3- Lights up orange when the door is locked.
- Lights up green when the door is unlocked.
4 Door
5 Sample loading bay
To insert the sample holder into the Phenom.
6 Sample holder
7 USB ports
- To insert the supplied USB Flash drive.
- To insert the mouse USB connector or the rotary knob USB connector.
8Operates the Phenom together with the touch screen and the rotary knob.
9Operates the Phenom together with the touch screen and the mouse (ProX / Pro).
10 To store images on.
10
Fig. 1
PW_Phenom_Pro_X_Pro_Pure_Print:PW_Phenom_G2_Pro_G2_Pure 19-11-13 20:54 Pagina 10
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Microscopio de Phenom
Manuales populares de Microscopio de otras marcas

VWR
VWR VisiScope 384 Series Manual de usuario

Nikon
Nikon ECLIPSE E200 POL Manual de usuario

Leica
Leica DI C800 Manual

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manual de usuario

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manual de usuario

Olympus
Olympus SZ61 Manual de usuario