SPECIAL FUNCTION
OPERATING PRINCIPLE OF THE SENSOR
SENS: Detection distance: two meters; it is an approximate value which will change according to detection
object’s size.Detection distance: six meters; it is an approximate value which will change according to
detection object’s size.Detection distance: maximum; it is an approximate value which will change according
to detection object’s size.
1. LUX value adjusting, press the 50 LUX button, the sensor will flicker twice, press again, and it will flicker twice
again. Press the third time; it indicates that the unit enters the rundle adjusting mode, then “10LUX” is used as
the DOWN key, “50LUX” the median key, “>1000”the UP key; There are seven gears below, press
the“10LUX”button, the indicator will flicker one time ( power off one time), when reaching the minimum value,
the indicator doesn’t flicker, remaining on all the time. If you don’t set the unit at this moment, it will enter the
detection state three seconds later ( set the valid time being ten seconds after the last time); This is also applied
to the “>1000”and “10LUX”buttons. If you are not satisfactory with the set value or for other reasons, you can
press the “50LUX”reverting to the median value, after the indicator flickers three times, you can reset it; the
rundle adjusting function can withdraw automatically, the set time is ten seconds after the last time you input the
button
2. Time setting adjusting, the same as the adjustment above, the difference is that pressing the “5MIN”button
enters time setting, “8S”is used as DOWN key, “5M” as the median key, “12M”as Up key. When the time rundle
adjusting is used, the minimum time is eight seconds, the maximum time is 12 minutes, one gear equates to 30
seconds.
3. Distance adjusting, the same as the way listed 1, press the “6M”there times entering the distance adjusting
state, “2M”button is used for DOWN key, “6M”as reverting to median value button, “MAX”used as UP key, the
minimum value is two meters( approximate value).
After the sensor is powered on, the indicator will keep on for five seconds (the period may alter), entering the
detection state 10 seconds later, you can set its sensitivity, delay time, luminance via the three knobs on the
sensor. The indicator will flicker (no matter whether it is turn on or not), the lock time is four seconds after the
sensor is power on. During this period whatever you operate the sensor, it won’t activate, but the indicator will
flicker according to detection.
When the above button is input, the indication light will flicker twice.
The remote controller has the rundle adjusting function.
Microwave Sensor
PD-MV1009 instruction
www.pdlux.com Tel: 86-574-83008608
TIME: Adjust time-delay of load work.The time delay is about 8s when turn in to 8s.The time delay is about
12min when turn in to 12min.
FUNCTION
①LUX:When luminance is less than 10 LUX, enable the
light to power on, for the use at night. When luminance
is less than 50 LUX, enable the light to power on, for the
use when ambient luminance is not enough. When
luminance is more than 1000 LUX, enable the light to
power on, for the use when it is in the daytime.
AUTO=“AUTO”mode, enable the sensor to detect
ON= Always on, about six hours later turn to “AUTO”mode
OFF= Always off, about six hours later turn to “AUTO”mode ①
SENS