Paramont MS-1500W0IRPH Manual de usuario

- 1 -
IMPORTANT: Read this manual before operating this unit and follow all instructions.
Stationary Infrared Electric
Pole Mount Patio Heater
Model #: MS-1500W0IRPH,
LIP-15-TGG-SP
PH-E129
C US
FAILURE TO FOLLOW WARNINGS & OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL
CAN RESULT IN SEVERE PROPERTY DAMAGE AND/ OR PERSONAL INJURY

- 2 -
Safety Guidelines
Read this manual carefully for guidance on the assembly and use of this product.
Indicates a potentially hazardous situation which,
if not avoided, WILL result in serious injury or
death.
Indicates a potentially hazardous situation, if not
avoided, COULD result in serious injury or death.
Indicates a potentially hazardous situation which,
if not avoided, MAY cause moderate injury or
damage to the equipment.
Indicated important information that if not
followed, may cause damage to the equipment.
1
.
Risk of Fire. There is always a risk of fire when working with a heater. Keep
heater away a
minimum of 25 ft
. from flammable liquids and materials.
2.
Risk of Fire. Do not use the unit until it has been mounted to the ground. I
f the unit falls on
the ground, it may start a fire. Ensure that the heater is placed is stable a
nd is placed on a level
surface
and mounted in place. Follow instructions above and also for further prevention, kee
p this unit
at least 3 feet (.9m
) clear from any objects.
3.
Hot or Burn Hazard. This unit may be extremely hot while in use
. Careful when handling
especially around the head of the unit.
4.
Electrical Hazard. Disconnect from electrical outlet before working on the unit to avoid
chance of electric
al shock.
5. Electric Shock. Do not use near water. Do not use if cord has been damaged.
Improper treatment of the heater can damage it and also shorten its life span.
To prevent electrical shock
, ensure electrical plug is properly inserted into the electrical outlet.
Unit is hot when operating keep at least 3’ away from everything. Do not place any objects
such as furniture, papers, clothing or curtains closer than 3’ to the fr
ont and sides of the heater.

- 3 -
Overview
Bottom Stand Pole - supports this lightweight
heater. Electrical cord runs inside this pole.
Head Post / Telescope Body –
Adjusts height and direction
of heat emission.
Base - supports the unit. Mount securely
on surface.
The Patio Heater
Parts List –
Screws –
Head/Heating Unit -
120 Volt (AC)/1500 Watt
electric heater with
rotating head and
safety grill.
Mounting holes
Mount to ground.

- 4 -
IMPORTANT INSTRUCTIONS
1. Read all instructions before using this heater.
2. This head (heating element) will get very hot
while in use. To avoid burning, do not let bare
skin touch the hot surfaces. If provided, use
handles when moving this heater. Keep
flammable materials, such as furniture, pillows,
bedding, papers cloths, and curtains at least 3
feet (0.9m) from the heater.
3. DO NOT LEAVE the heater unattended.
Extreme caution is necessary when any heater
is used by, or near, children or disabled
persons, and whenever the heater is left
operating and unattended
4. Always unplug heater when not in use.
5. Do not operate any heater with a damaged
cord or plug, if the heater malfunctions, or has
been dropped or damaged in any manner.
Return heater to authorized service facility for
repairs.
6. Operate 3 feet (0.9m) from people or objects.
FOR OUTDOOR USE ONLY
7. Never operate heater near water or where it
can be knocked over.
8. Do not run cord under carpeting. Do not cover
cord with throw rugs, runners, or similar
coverings. Arrange cord away from traffic area
and where it will not be tripped over.
9. Connect to properly grounded outlets only.
10. Do not use near flammable materials. Do not
use it in areas where gasoline, paint, or
flammable liquids are used or stored.
11. Use this heater only as described in this
manual. Any other use not recommended by
the manufacturer may cause fire, electrical
shock, or injury to persons.
12. Avoid the use of an extension cord because
the extension cord may overheat and cause a
risk of fire. However, if you have to use an
extension cord, use either a 12 or 14 gauge
wire which is rated not less then 1900 watts.
The recommended length for a 14 gauge is 0-
50 feet, but if need be long use a 12 gauge no
longer then 100 feet.
13. Only one infrared heater suggested per
household. Special wiring required if more than
one heater is needed.
14. SAVE THESE INSTRUCTIONS for future
reference.

- 5 -
Assembly – Head Unit (Heating Element)
1. After taking the unit out of the box, put tilt switch on bracket.
2. Put bracket with tilt switch to heating unit
3. Place head post on bracket , keep
4.
Next place the head of the unit on to the
telescope body. Keep pulling the cord through
the bottom hole.
4IP+EEPHEADUNITINSTYROFOAMCASINGTOPROTECTFROMDAMAGEWHILEASSEMBLING
4IP$ONOTTIGHTENSCREWSUNTILASSEMBLYOFUNITISCOMPLETE
5. Slide the cord all the way down to the bottom
of the body and pull it out the special hole on
the side.
pulling the cord in the through the post.

- 6 -
Assembly (continued)
6. Pick up the body now with the head on it and stand it in the base. Line it up in the
screw holes and put the screws in.
7. For added safety, install the heater
head angle restrictor using 4 bolts. This
restricts the maximum angle the heater
head can be turned. The safety
arms act as a deflector to prevent
contact of any flammable material
and the heater head.
8. Find any flat area to support the unit
squarely so it cannot be tipped over.
Ensure no flammable materials can
come in contact. Mount the unit securely
to the ground using the provided
mounting hardware.
offset stainless steel
mounting pole
offset stainless steel
mounting pole

- 7 -
Operations
12.5amps
120 volts
1500 watts
Model:
J&R Home Products Ltd.
Grounding Instructions
The infrared electric patio heater comes equipped with a cord with an appropriate plug. The plug
must be used with an outlet that has been installed and grounded in accordance with all local codes
and ordinances. Make sure that the infrared electric patio heater is connected to an outlet having the
same configuration as the plug (see illustration). Do not use an adapter with this product. Check with
a licensed electrician if the grounding instructions are not understood completely or if the wall outlet
does not match the plug.
MS-1500W0IRPH / LIP-15-TGG-SP

- 8 -
Heating Tube: Installation/Replacement
1. Remove power cord from power socket, make sure heater has no power connection.
2. Use screw driver to take off side covers (shown in diagram ref. 2).
3. Remove panels and grill protector (diagram, ref. 3).
4. Remove tube from both terminals (on either side) (diagram, ref. 4).
5. Insert new tube into clipper and plug in both terminals. Make sure there are no metal parts around or
touching the heating tube.
6. Turn power on to check the newly placed heating tube. Then put back grill and both panels, screwing on
both side covers.
7. Store in a safe place were the unit won’t get damaged or broken.
2
Tube
2
Side Cover
Grill
Panel
Terminal
Clipper
3
3
3
4
4
4

- 9 -
Troubleshooting
Problem Probable Cause Solution
No power Check plug connection with power
outlet
Heating tube is damaged Replace with new heating tube
Tilt switch not connected Keep body vertical
Tilt switch is damaged Replace new limit switch
Heating tube will not light
Loose connection Check and tighten connections
Heating element glows
unevenly from end to end.
Check if heater head is leveled.

- 10 -
Warranty
Our products have been manufactured under the highest standards of quality and workmanship.
We warrant to the original consumer purchase that all aspects of this product will be free of defects in
material and workmanship for one (1) year from the date of purchase.
A replacement for any defective part will be supplied free of charge for installation by the consumer.
This warranty is valid for the original consumer purchaser only and excludes
product abuse, or product misuse, whether performed by a contractor, service company, or consumer.
We will not be responsible for labor charges and/or damage incurred in installation,
repair or replacement, nor for incidental or consequential damage.
This warranty gives you specific legal rights and you may also have other rights which may vary from state,
province to province, and nation to nation. If you are not satisfied with the performance or the quality of
this product, the valid refund period is 30 days after the date of purchase. Any return after this period will
not be allowed. You may call us or simply write to us using the address below. Explain the defect and
include proof of purchase and your name, address and telephone number. We will advise you of the
procedure to follow in making warranty claim.
J&R Home Products Ltd.
Unit 1-5628 Riverbend Drive Burnaby, BC V3N 0C1
1-800-561-5550
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Idiomas: