Paradyne FrameSaver SLV 9580 T3 ATM DSU Manual de usuario

TM
1
9580-A2-GZ40-10 June 1999
FrameSaverSLV 9580 T3 ATM DSU
Installation Instructions
Document Number 9580-A2-GZ40-10
June 1999
Installation Checklist
Installation of the FrameSaver SLV 9580 DSU requires the following steps:
Verify the contents of the shipping carton
Mount the DSU in a cabinet or on open rails
Connect the DSU to a power source
Monitor the power-up self-test
Connect the DSU to its DS3 interface
Connect the DSU to its DTEs
Connect the DSU to an Ethernet interface
Connect the DSU to a terminal or PC, directly or through a modem
Enter a device profile
Set up system Login IDs and access levels
Configure the system
— Configure management PVCs and any other unique PVCs
— Enter and configure VPI/VCIs if your switch does not support traffic
descriptors
— Configure and run Auto-Configuration
Connect the DSU to its monitor and NetScout Probe, if used
Test the system
At any step, diagnose and correct any errors.
Physical installation is described in this document. For detailed configuration and
troubleshooting information, see the
FrameSaver SLV 9580 T3 ATM DSU User’s
Guide
(9580-A2-GB20).

2 9580-A2-GZ40-10
June 1999
Checking the Contents of the Shipping Carton
The shipping carton for your FrameSaver SLV 9580 DSU should contain:
FrameSaver SLV 9580 DSU
Two DS3 network cables
One power cable for each power supply installed
Two mounting brackets
Installation kit containing machine screws and other hardware
Installation instructions
User’s guide
Notify your supplier if anything is missing or damaged.
Mounting the FrameSaver SLV 9580 DSU
The FrameSaver SLV 9580 DSU can be mounted in a standard 19-inch or
23-inch cabinet or open rails, and either flush with the mounting rails or
approximately 4 inches forward of the rails. The different configurations are
accommodated by positioning two mounting brackets.
The following procedure requires:
A fiber-tip marking pen
A large Phillips screwdriver
Mounting brackets and #8 flathead machine screws
Four self-retaining nuts (for rails with unthreaded holes)
Four #10 machine screws (for use with self-retaining nuts or rails with small
threaded holes)
Four #12 machine screws (for rails with large threaded holes)
The mounting brackets, machine screws, and self-retaining nuts are supplied
with the FrameSaver SLV 9580 DSU.

3
9580-A2-GZ40-10 June 1999
Procedure
To install the FrameSaver SLV 9580 DSU in a standard rack:
1. Determine the general position of the FrameSaver SLV 9580 DSU in the
rack. Hold one of the mounting brackets in that position and align it so that
the notches in the keyed holes of the bracket line up precisely with holes in
the rail.
2. Mark the holes in the rail where the two machine screws will go. Then mark
the opposite rail in the same positions.
3. If the rack has threaded holes, go to Step 4. If the rack does not have
threaded holes, fit self-retaining nuts over the rails at the marked holes.
4. Using a large Phillips screwdriver, put machine screws at the two bottom
screw positions you marked. Leave the screws loose enough that the
mounting brackets can slide over them.
98-16023

4 9580-A2-GZ40-10
June 1999
5. Determine the size of the rack you are installing the DSU in.
The brackets must be mounted with the:
— Wide side of the brackets against the body of the DSU for a 19-inch rack
— Narrow side of the brackets against the body of the DSU for a 23-inch
rack
Use the screw holes:
— Nearest the front of the DSU to mount it flush with the rails
— Four inches from the front of the DSU to mount it overhanging the rails
(forward mount)
The keyed holes are at the bottom of the brackets when they are positioned
correctly.
6. Fasten the mounting brackets to the DSU with four #8 flathead screws.
FrameSaver
TM
SLV
9580
AIS
XMT
RCV
LCV
OOF
LOS
YEL
PORT1
TD
RD
DSR
DTR
PORT2NETWORK
TD
RD
DSR
DTR
SYSTEM
OK
ALM
TST
PWR
FAN
98-16022
19-inch Rack
Forward Mount
23-inch Rack
Flush Mount
23-inch Rack
Forward Mount
FrameSaver
TM
SLV
9580
AIS
XMT
RCV
LCV
OOF
LOS
YEL
PORT1
TD
RD
DSR
DTR
PORT2NETWORK
TD
RD
DSR
DTR
SYSTEM
OK
ALM
TST
PWR
FAN
FrameSaver
TM
SLV
9580
AIS
XMT
RCV
LCV
OOF
LOS
YEL
PORT1
TD
RD
DSR
DTR
PORT2NETWORK
TD
RD
DSR
DTR
SYSTEM
OK
ALM
TST
PWR
FAN
19-inch Rack
Flush Mount
FrameSaver
TM
SLV
9580
AIS
XMT
RCV
LCV
OOF
LOS
YEL
PORT1
TD
RD
DSR
DTR
PORT2NETWORK
TD
RD
DSR
DTR
SYSTEM
OK
ALM
TST
PWR
FAN

5
9580-A2-GZ40-10 June 1999
7. Lift the FrameSaver SLV 9580 DSU into position in the rack, putting the
screws through the keyed holes of the bracket. Lower the DSU onto the
screws.
98-16024
8. Put a machine screw through the top hole of each bracket and tighten the
screw. Tighten the bottom screws.

6 9580-A2-GZ40-10
June 1999
Connecting to Power
The FrameSaver SLV 9580 DSU can be powered by one or two power modules.
Each is supplied with a power cable.
Procedure
To install the power cable:
1. Verify that the switch on the power module is in the Off (0) position.
2. Push the 3-hole connector of the power cable into the power receptacle on
the back of the FrameSaver SLV 9580 DSU. Fix the cable to the rail with a
cable tie or other strain relief device.
3. Connect the other end of the power cable to a grounded 110 Vac power
source.
4. Push the switch on the power module to the On (1) position.
98-16033
110 Vac
UPS
110 Vac
LAN
If two power modules are used, connect them to separate power sources. If one
power source fails, the FrameSaver SLV 9580 DSU continues to run.

7
9580-A2-GZ40-10 June 1999
Power-On Self-Test
When power is applied to the FrameSaver SLV 9580 DSU, it performs a series of
internal tests. The SYSTEM TST and SYSTEM OK LEDs are on during the
power-on self-test. When the test is complete, all LEDs light up for about five
seconds, then assume their assigned functions. After the test:
If the test ran with no errors, the SYSTEM OK LED stays on and the
SYSTEM ALM (Alarm) LED turns off.
If any step of the power-on self-test failed, the SYSTEM OK LED cycles on
and off rapidly (10 times per second) and the SYSTEM ALM LED stays on.
If the processor failed, the SYSTEM OK and SYSTEM TST LEDs stay on.
If the power-on self-test failed, a message describing the failure can be displayed
on the Health and Status screen of the Asynchronous Terminal Interface.
Self-Test Results Messages
Message What It Indicates What To Do
Bypassed Self-test was disabled when
the unit was powered up or
reset.
No action needed.
CPU Fail The CPU failed internal
testing. 1. Reset the unit and try again.
2. Call your service representative for
assistance.
3. Return the unit to the factory.
Network T3 Fail The FrameSaver SLV 9580
DSU failed to internally loop
data on the network T3
circuit.
1. Verify the connection between the
unit and the T3 source.
2. Reset the unit and try again.
3. Call your service representative for
assistance.
4. Return the unit to the factory.
Memory Fail Memory verification failed. 1. Reset the unit and try again.
2. Call your service representative for
assistance.
3. Return the unit to the factory.
Failure
ffffffff
An internal error has
occurred, identified by the
8-digit hexadecimal code
ffffffff
.
1. Record the failure code; reset the
unit and try again.
2. Call your service representative for
assistance.
3. Return the unit to the factory.
Passed No problems were found
during power-up or reset. No action needed.

8 9580-A2-GZ40-10
June 1999
Connecting the DS3 Network Cables
Connection to the DS3 network requires two BNC-to-BNC coaxial cables. The
cables are shipped with the FrameSaver SLV 9580 DSU.
Procedure
To install the DS3 network cables:
1. Take the end of the receive cable and push it onto the DS3 RX (Receive)
connector on the back of the FrameSaver SLV 9580 DSU. Turn the cable
connector clockwise to lock it.
2. Take the end of the transmit cable and push it onto the DS3 TX (Transmit)
connector on the back of the FrameSaver SLV 9580 DSU. Turn the cable
connector clockwise to lock it.
3. Fix the cables to the rail with a cable tie or other strain relief device.
4. Connect the receive and transmit cables to the output and input connectors,
respectively, of the DS3 source.
RX MON
TX
RX
TX MON
DS3
Network
Interface
98-16025
12
35
4
5. If the DS3 source device has a variable line build out (LBO) setting, ensure
that it is matched to the cable length.
6. If the cable length is longer than 100 feet (30 meters), set the LBO on the
Network Interface Options configuration screen to Long. The default is Short.
Follow this menu selection sequence to change LBO:
Main Menu
→
Configuration
→
Network Interface

9
9580-A2-GZ40-10 June 1999
Connecting the DTE Cables
The FrameSaver SLV 9580 DSU can be connected to two DTEs. Each may have
either a HSSI or a V.35 interface. The FrameSaver SLV 9580 DSU automatically
detects the presence of a V.35 adapter. If Port Type is set to HSSI and a V.35
adapter is installed, or if Port Type is V.35 and a V.35 adapter is not installed, an
error message is displayed on the Health and Status screen and the Port-
n
Physical Options configuration screen. The port is not usable when the Port Type
and cable do not match.
The DTE sockets require 50-position 0.5-inch straight exit connectors. Molded
connectors cannot be used. DTE cables are not supplied with the DSU.
NOTE:
If you wish to isolate the router from network activity until proper network
operation has been verified, do not connect the router to the DSU until the
network has been configured and network connectivity has been verified.
Procedure
To install a V.35 or HSSI DTE cable:
1. Press the 50-pin connector of the HSSI cable or the V.35 adapter onto the
DTE P1 or DTE P2 socket on the back of the DSU until the latches lock.
2. For a HSSI cable, proceed with Step 3. Connect the V.35 cable to the V.35
adapter, providing appropriate strain relief.
3. Fix the cable to the rail with a cable tie or other strain relief device.
4. Connect the other end of the cable to the appropriate port of your DTE.
12
35
4
DTE P1
DTE
98-16027
Do not substitute a SCSI-2 cable for a HSSI cable. Although apparently
similar, a SCSI-2 cable may not accommodate high speeds without errors.

10 9580-A2-GZ40-10
June 1999
Connecting the LAN Cable
The LAN port can be connected to an Ethernet hub using a standard 10BaseT
cable, or to a Network Interface Card (NIC) in a PC using a crossover cable. The
LAN port provides a high-speed connection that can be used for FTP and Telnet
sessions.
The default IP address for the port is 192.168.0.1. The default subnet mask is
255.255.000.000.
A LAN cable is not supplied with the FrameSaver SLV 9580 DSU.
Procedure
To connect the FrameSaver SLV 9580 DSU to an Ethernet hub or NIC:
1. Select the correct cable:
— To connect the LAN port to a hub, use a standard 10BaseT cable
— To connect the LAN port to a NIC, use a 10BaseT crossover cable
2. Insert the 8-pin modular connector of the cable into the LAN socket on the
back of the FrameSaver SLV 9580 DSU. It locks in place when it is fully
seated.
3. Fix the cable to the rail with a cable tie or other strain relief device.
4. Connect the other end of the cable to your LAN hub or NIC.