Panasonic SR-DE183 Manual de usuario

Order No. PHAT101101CE
(Revision : Jul. 2011)
Service Manual
Electronic Warm Jar
SR-DE103 / SR-DE183
SR-MS103 / SR-MS183
Product Colour
White (W)
Destination
Thailand, Hong Kong, Malaysia,
Singapore (RBD), Indonesia, PSV,
Singapore (DBD), Taiwan,
USA & Canada, Panama,
Australia & New Zealand.
© Panasonic Home Appliances (Thailand) Co., Ltd. 2010.
All rights reserved. Unauthorized copying and distribution
is a violation of law.
There are special components used in this equipment which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that
these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards. Do
not modify the original design without permission of manufacturer.
IMPORTANT SAFETY NOTICE
SR-MS103 / SR-MS183SR-DE103 / SR-DE183

- 2 -
CONTENT
Page
3
4
5
6
7
8
9
9
10
11
12
13
13
13
14 - 16
17
18
19
20
21 - 22
23 - 24
1. Warning
2. Specification
3. Diagram
3.1 Circuit Diagram
3.1.1 SR-DE103 / SR-DE183
3.2.1 SR-MS103 / SR-MS183
3.2 Block Diagram
3.3 Wiring Diagram
4. Troubleshooting
4.1 Before troubleshooting
4.2 Self-diagnosing
5. Troubleshooting-Part I (for the main unit)
6. Quick Check Test for the Control Board
7. Troubleshooting-Part II (for the P.C.B.)
8. Test Method
8.1 Bubble Test
8.2 Steaming Test
8.3 Keep Warm Test
9. Replacing of P.C.B. (Comp.)
10. Replacing of Cast Heater
11. Replacing of Pan Sensor and Thermal Fuse
12. Parts Exploded View and Replacement Parts List
12.1 Part Exploded View
12.2 Packing View
12.3 Replacement Parts List : SR-DE103 / SR-DE183
12.4 Replacement Parts List : SR-MS103 / SR-MS183
SR-DE103, 183 / SR-MS103, 183

SR-DE103, 183 / SR-MS103, 183
- 3 -
1. WARNING
Accessory
The service information is designed for experienced repair technicians only and is not designed for use by the general
public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting
to service a product. Products powered by electricity should be serviced or repaired only by experienced professional
technicians. Any attempt to service or repair the product or products dealt within this service information by anyone
else could result in serious injury or death.
WARNING
Scoop Measuring cup Steaming
basket
Power cord
Outer lid
Pan
Handle
Body

- 4 -
2. SPECIFICATION
MODEL SR-DE103 SR-DE183 SR-MS103 SR-MS183
Colour Name
Colour Code
Power Consumption
White White White White
WWWW
120V/50Hz USA & Canada
Panama
-
220V/50Hz Thailand
Hong Kong
Thailand
Hong Kong, PSV
Singapore (RBD)
Indonesia
USA & Canada USA & Canada
Cooking 750W 750W 750W 750W
Cooking Capacity White Rice 1 ~ 5 cups 1 ~ 5 cups2 ~ 10 cups 2 ~ 10 cups
Product Dimension Width 274 mm 274 mm274 mm 274 mm
Weight Approx. 2.8 Kg 2.6 Kg3.1 Kg
Thermal Fuse Specification
Accessories
* If any change occurted to the appearance, wiring or other parts of the warm jar due to property improvement
or other reasons, there will be additional notice.
Keep Warm
Temperature
Others 75 ± 4 ˚C
Indonesia 77 ± 4 ˚C
3.0 Kg
Depth 351 mm 351m351 mm 351 mm
Height 197 mm 197 mm245 mm 245 mm
Keeping Warm 70W 80W 77W 87W
Thailand
Hong Kong, PSV
Singapore (RBD)
Thailand
Hong Kong, PSV
Singapore (RBD)
USA & Canada
Panama 73 ± 4 ˚C
127 ± 6 ˚C
Center Thermostat Working Temperature
172 ˚C
Steaming basket, Scoop, Measuring cup, Power cord
230V/50Hz Singapore (DBD) Singapore (DBD)
Malaysia, AUS/NZ
Singapore (DBD) Singapore (DBD)
240V/50Hz Malaysia, AUS/NZ AUS/NZ AUS/NZ
Power Supply 110V/60Hz Taiwan Taiwan Taiwan Taiwan
SR-DE103, 183 / SR-MS103, 183

SR-DE103, 183 / SR-MS103, 183
- 5 -
3. DIAGRAM
3.1 Circuit Diagram
3.1.1 SR-DE103 / SR-DE183

- 6 -
3.1.2 SR-MS103 / SR-MS183
SR-DE103, 183 / SR-MS103, 183

SR-DE103, 183 / SR-MS103, 183
- 7 -
3.2 Block Diagram
NL
Lid heater
Control board (Power side)
Socket
Grounding wire
Cast heater Control board (Operating side)
Side heater
Lid earth lead wire
Lid sensor

- 8 -
3.3 Wiring Diagram
SR-DE103, 183 / SR-MS103, 183
Terminal ejector should be
opposite to the component
2
2
2
Lead wire A for the
thermal fuse assy B
Earth lead wire
Lead wire A
Lead wire C for thermal fuse assy B
Thermister earth lead wire
Lead wire assy
Lid sensor assy
Lead wire B assy
Hinge earth lead wire
Lid earth lead wire
Lid heater assy
Lead wire A for
thermal fuse assy

SR-DE103, 183 / SR-MS103, 183
- 9 -
4. TROUBLESHOOTING
Before repairing the warm jar from users, please confirm whether it is complete (pan, lid, keep warm pin, etc.)
and inquiry the user for specific malfunctions. Please turn off the power before checking the circuit or
component.
Troubleshooting will be proceeded in two steps, one for the main unit and the other for control circuit board.
Please refer to part I before any checking. If the malfunctioned item is unavailable in the troubleshooting
table, please proceed the basic test to check the control circuit board (refer to page 7). Then decide proper
measures according to the troubleshooting description in part II.
The malfunctioned component and its location are indicated in the right side of trouble symptom.
Each component is designated with a number of checking sequence, please refer to it. Please refer to page 7
for information of diagnosing the malfunctioned parts on panel (for reference only).
4.1 Before troubleshooting
4.2 Self-diagnosing
Display
Symbol Symptom
The “Keep Warm” function is cut off
automatically when the operation
exceeds 96 hours.
All the buttons are inoperative.
Press [ Keep Warm / Off ] button to resume keeping
warm (Do not set keeping warm for more than 12 hours).
Replace the pan sensor (pan sensor is broken off), or
check the branch component of pan sensor on the
computer panel.
All the buttons are inoperative. Replace the pan sensor (pan sensor is broken off), or
check the branch component of lid sensor on the
computer panel.
All the buttons are inoperative. Replace relay or P.C.B. (Cause : The relay is in fault).
Remedy
Precautions for operating microprocessor or control circuit
• The handling personnel should be well grounded.
• The iron should be grounded. Do not use the iron with poor insulation. The iron with microcomputer control
is suggested.
• Do not touch the IC pin or other components before grounded. Do not put the circuit board on conductive
surface that may be charged.
• Do not insert the components from reverse side of the circuit board.
• Do not apply high resistance (x10k) when proceeding continuous measurement with multi-meter, otherwire,
the IC and other components on the circuit board may be damaged due to the high voltage.
• Try to shorten the welding time (within several seconds).
• Please turn off the power before replacing any component.
• The transformer for control panel has a voltage of AC 110V, 120V, 220V, 230V, 240V, so please take care
when handling the electric control board to avoild electric shock or hurt.
The microcomputer is composed of CMOS digital IC and MOS FET, so it is quite sensitive to electrostatic,
such as electrostatic from body, clothes, iron, etc. Please handle it carefully as per following instructions :
The following symbols will appear on LCD automatically when it is abnormal.

- 10 -
5. TROUBLESHOOTING-PART I (for the main unit)
Note :
Drawing No. Remark
Malfunctioned
Component
15 23 44 48 48 54 61 6 22
Lid Heater
Cast Heater
Warming Heater
Pan Sensor
Thermal Fuse
Terminal
AC Cord
Outer Lid Comp.
Pan
Parts on the P.C.B.
Refer to page 8, when the
malfunctioned parts are
supposed to be on the
P.C.B.
Does not cook
Cooking LED
lights up
Unit
Description
Symptom
Cannot cook rice correctly
(stops early or cooking
is uneven, etc.)
This may occur due to user’s
improper measurement or
insufficient loosening of rice.
Rice on bottom of the inner
pan is scorched
Keep Warm temperature is
high (over 78 ˚C)
Check that there is on dirt or
foreign substances stuck to
the surface of the pan sensor.
This may occur by unplugging
or insufficient loosening of rice.
This may occur when the lid is
kept open for a long time,
insufficient loosening of rice or
falling of “Keep Warm” pin.
Mark means the components that may malfunction.
SR-DE103, 183 / SR-MS103, 183
LED does not
operate at all
Indicates
“H01” on LCD
Indicates
“H02” on LCD
Indicates
“H05” on LCD
Cooking LED
does not light
up
If the fuse melts, check and
remove the cause firstly, then
replace the malfunctioned part.
Keep Warm temperature is
low (below 68 ˚C)
Does not
Keep warm
Keep Warm
LED lights up
Droplets fall onto the surface
of rice
The surface of rice dries up
The bottom of warm jar melts
and fires
Otros manuales para SR-DE183
2
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Calentador de alimentos de Panasonic