PACH & COMPANY AeGIS AFGR9 Instrucciones de montaje

AeGIS AFGR9
Installation and Programming Manual
Pach & Company 941 Calle Negocio Phone: 1-888-678-7224
www.pach-co.com San Clemente, CA 92673 Fax: 949-498-6879
July 28, 2004

TABLE OF CONTENTS
Chapter 1 Getting Started ........................................................................................... 1
1.1 Introduction................................................................................................................ 1
1.2 System Description ................................................................................................... 1
1.3 System Specification ................................................................................................. 1
1.4 System Accessories .................................................................................................. 2
1.5 Unpacking The System ............................................................................................. 2
Chapter 2. Installation ................................................................................................. 3
2.1 Wiegand Interface Connection ........................................................................... 5
2.2 Standalone Unit Connection ............................................................................... 6
2.3 RS-485 Connection ............................................................................................ 7
2.4 RS-232 Backup Database Connection .............................................................. 8
Chapter 3. Set Parameters .......................................................................................... 9
3.1 Power Up the System ........................................................................................ 9
3.2 Date Display Mode ............................................................................................. 10
3.3 Time Display Mode ............................................................................................. 11
3.4 Back Light ........................................................................................................... 11
3.5 Facility Code ....................................................................................................... 12
3.6 Relay Select ........................................................................................................ 13
3.7 Digital Input ......................................................................................................... 13
3.8 Relay 1 Duration ................................................................................................. 14
3.9 Relay 2 Duration ................................................................................................. 15
3.10 ADMIN Code ....................................................................................................... 16
3.11 MAGIC Code ....................................................................................................... 16
Chapter 4. Enrollment .................................................................................................. 18
4.1 Primary Finger Print Enrollment .......................................................................... 18
4.2 Replace the Primary Enrollment .......................................................................... 19
4.3 Secondary Finger Print Enrollment ...................................................................... 20
Chapter 5. Special Enrollment ..................................................................................... 22
5.1 Primary Finger Print Special Enrollment .............................................................. 22
5.2 Replace the Primary Special Enrollment ............................................................. 23
5.3 Secondary Finger Print Special Enrollment ......................................................... 24
Chapter 6. User Dir ........................................................................................................ 25
Chapter 7. Delete User .................................................................................................. 26
Chapter 8. Delete All Users .......................................................................................... 27
Chapter 9. Set Time/Date .............................................................................................. 28
Chapter 10. Install Software ......................................................................................... 29
Chapter 11. Backup the Database ............................................................................... 32
Chapter 12. System’s Operation .................................................................................. 35

LIMITATIONS OF LIABILITY
This manual is subject to change without notice.
Pach & Company is not liable for any errors that might occur from use of this document, nor is any
commitment to update the information herein implied.
Pach & Company does not assume any liability for any damages, which may arise in installation or use of the
AeGIS AFGR9.
Pach & Company does not assume liability for any incompatibility between the AeGIS AFGR9 and user devices.
Pach & Company reserves the right to make changes without prior notice to any products in order to improve
reliability, function or design.
WARRANTY
The AFGR9 comes with TWO (2) YEARS WARRANTY FOR MANUFACTURER’S PARTSAND MANUFACTURING
LABOR .We will include lightning strikes in our two years warranty if our ASP1 surge protector is installed with the systems.
If you use other than Pach and Company ASP1 Surge Protector, you are responsible to claim the damages to the surge
protector manufacturer. The above warranties are subject to the following conditions.
• The products must be properly installed as specified, maintained, used as intended.
• The serial number on the printed circuit board must match the serial number on the cabinet.
• The system's failure is not caused by vandalism, improper instillation, misuse or abuse.
• Physically damaged product is not acceptable for repair or exchange within our warranty.
• The warranty will be void and null if the product has been repaired or modified by unauthorized party
without authorization from the Pach & Company Technical Department.
• If for some reason your system cannot be repaired, Pach and Company will replace it with an
identical product of equal value.
• You must obtain a Return Merchandise Authorization (RMA) number from Pach & Company
Technical Department before you can send back the product to factory for repair.
• You are responsible for all transportation and insurance charges for the products shipped to the Pach
& Company repair center.
• Pach & Company will not reimburse your time and labor cost to install, uninstall or reinstall
hardware/software/firmware for enhancements or bugs fixed or systems failures.
• PACH AND COMPANY WILL NOT COVER THE FIELD LABOR TO INSTALL, REMOVE AND
TROUBLE-SHOOT THE SYSTEM.

CHAPTER 1. GETTING STARTED
1.1 Introduction
Pach & Company thanks and congratulates you on the purchase of your AeGIS AFGR9 Biometric Fingerprints Reader with
26-Bit Wiegand Output.
The manual is designed to guide you through the proper programming and use of the AeGIS AFGR9. It is important for you
to read and follow the manual completely.
The Aegis AFGR9 comes with two years warranty (see warranty on previous page). We will include lightning strikes in our
two years warranty if Pach & Company surge protector (ASP1) is installed with the system.
1.2 System Description
The AeGIS AFGR9 is a Biometric Fingerprint Reader with 26-Bit Wiegand Output and 1000 Template/Access
Code Capacity. The system can be installed as a standalone, Wiegand interface with the AeGIS 9000 Series or
RS-485 using our AWCRM (AeGIS 26-Bit Wiegand Card Reader Module).
1.3 System Specifications
Standard Features
• 500 DPI Optical Finger Print Sensor.
• 1000 Template/Access-Code capacity.
• One 26-Bit wiegand Output.
• Two RS-232 (115200 Bps) for database backup and firmware upgrade.
• 2x16 character Liquid Crystal Display with backlit.
• Local Access keypad entry code.
• Standalone, Wiegand Interface or RS485 application with optional controller module (AWCRM).
• Brushed stainless steel faceplate, surface mount, indoor or outdoor.
Specifications
• Processor 8 bits CMOS, 18,432 MHz
• Real time clock.
• Memory : DATA 128 KB SRAM (volatile) with battery backup Li-Mn 3V CR2450 (3 years life time).
PROGRAM 256 KB Flash.
• Power 12VAC/DC, 12 VAC transformer is supplied.
• Current Consumption: 300 mA idle, 500 mA peak.
• Temperature range32°F to +140°F Relative Humidity 0% to 95% non-condensing.
* Heater Pad (AHP5) is required if the ambient temperature is below 32°F.
• Two Relays 125VAC 500mA, 110VDC 200mA or 24VDC 1.0A.
• Programming port for database download and firmware upgrade.
• Dimension: 5.32” x 8.07’ x 2.76” (WxHxD).
• Approximate shipping weight: 7 Lbs.
Pach and Company Page 1 07/28/04
AFGR9 Chapter 1. Getting Started

1.4 System Accessories
1.5 Unpacking the System
Check the serial number on the printed circuit board and cabinet, they must be matched. If they don’t match
contact, return the product to your distributor or call Pach and Company at 1-888-678-7224. All the items below
come with the system.
• AFGR9 System.
• XMFR (12VAC Power Transformer).
• One-2 pins terminal connector (inside the unit).
• Two- 12pins terminal connector (inside the unit).
• RS-232 cable.
• Set of keys.
Part Number Description
ASP1 AC and Telephone Surge Protector.
AHP5 Heater pad with thermostat.
AWCRM AeGIS 26-Bit Wiegand Card Reader Module.
AKYS AeGIS key sets (2 keys per set).
AFGR9MAN AeGIS AFGR9 manual.
XMFR 12VAC power transformer.
Pach and Company Page 2 07/28/04
AFGR9 Chapter 1. Getting Started

CHAPTER 2. INSTALLATION
A proper installation of the AeGIS system is very essential. Improper installation will void the warranty. The
AFGR9 can be installed as Wiegand Interface with the AeGIS 9000 Series, Standalone unit or RS-485 using
Figure 2.1 Printed Circuit Board
Pach and Company Page 3 07/28/04
AFGR9 Chapter 2. Installation

Pach & Co AWCRM (26-Bit Wiegand Card Reader Module).
Pins Configuration
Pin Number Label on the Board Detail Description
1Earth GND Earth Ground Connection.
2R2COM Relay 2 common.
3R2NC Relay 2 Normally Close.
4R2NO Relay 2 Normally Open.
5R1COM Relay 1 common.
6R1NC Relay 1 Normally Close.
7R1NO Relay 1 Normally Open.
8GND System Ground (Do not
connect to earth ground).
9WGN_D1 Wiegand output data1
(maximum distance 500 ft
using 18 gauge wire).
10 WGN_D0 Wiegand output data 0
(maximum distance 500 ft
using18 gauge wire).
11 GND System Ground (Do not
connect to earth ground).
12 E_DATA External Data (Not used).
13 E_CLK External Clock (Not Used).
14 5V Out 5VDC auxiliary output with
respect to GND(Pin 8,11,15).
15 GND System Ground (Do not
connect to earth ground).
16 DOOR_SW Door Switch (Not used).
17 REX Request to EXIT.
18 D* RS-485 (not used).
19 DRS-485 (not used).
20 GND RS-232 Ground (To Pin 5on
DB9).
21 CTS0 RS-232 Clear to send.
22 RTS0 RS-232 Request to send.
23 RXD0 RS-232 Receive (To Pin 3 on
DB9.
24 TXD0 RS-232 Transmit (To Pin 2 on
DB9.
Pach and Company Page 4 07/28/04
AFGR9 Chapter 2. Installation

2.1 Wiegand Interface Connection
The AeGIS AFGR9 has one Wiegand output to interface with the AeGIS 9000 Series. The maximum distance
between the two units cannot exceed 500 feet using 18 gauge wire. There are four relays available if you use
the Wiegand Interface Connection: Two relays on AFGR9 (see figure 2.3) and two relays on AeGIS 9000
Series (See AeGIS 9000 Series Installation and Programming Manual). See figure 2.2 for wiring diagram.
Figure 2.2 WIEGAND INTERFACE
Pach and Company Page 5 07/28/04
AFGR9 Chapter 2. Installation

2.2 Standalone Unit Connection
The AFGR9 has two on board relay to control two doors at the same time. See figure 2.3.
Figure 2.3 STANDALONE
Pach and Company Page 6 07/28/04
AFGR9 Chapter 2. Installation

2.3 RS-485 Connection
An Optional RS-485 Wiegand Card Reader Module (AWCRM) must be used for this application.
The AWCRM has one built-in relay to control door or gate. You may also use the two built-in relays on the
AFGR9 to control
another door or gate (see figure 2.3)
Figure 2.4 RS-485
Pach and Company Page 7 07/28/04
AFGR9 Chapter 2. Installation
Tabla de contenidos
Otros manuales de Sistema de control de PACH & COMPANY

PACH & COMPANY
PACH & COMPANY AeGIS 9100CR200 Instrucciones de montaje

PACH & COMPANY
PACH & COMPANY AeGIS 7000 Series Manual de usuario

PACH & COMPANY
PACH & COMPANY AeGIS 4000 Instrucciones de funcionamiento

PACH & COMPANY
PACH & COMPANY AeGIS 8000 Series Manual de usuario

PACH & COMPANY
PACH & COMPANY AeGIS 100DIR Manual de usuario