CENTRAL HEATING BOILER
H 412,H 418, H 424, H 430
Content
1. Introduction 2
2 . Boiler Properties 2
3. Technical Description 3
4. Main Dimensions 5
5. Technical Parameters 10
6. List of Replaceable Spare Parts 11
7. List of Accessories Supplied 14
8. Servicing the Boiler 15
9. Boiler and Heating Equipment Maintenance 17
10. Safety Instructions for Boiler Assembly and Servicing 18
11. Waste Disposal 25
12. Determination of Storage Tank Size 26
12. Warranty Sheet 26
13. Registration Card 29
THE EUROPEAN REGIONAL DEVELOPMENT FUND AND THE
MINISTRY OF INDUSTRY AND TRADE OF THE CZECH
REPUBLIC SUPPORT INVESTMENT IN YOUR FUTURE.

Heat and Comfort
2
1. INTRO UCTION
Dear Customer,
We appreciate you have chosen a product originating from our product range, by which
you became one of our customers. We hope our product will serve you long and well.
This is contributed to by all the staff of the company and now it is up to you to make
your own contribution by reading carefully through the manuals and maintaining the
instructions and regulations specified therein.
May our products bring you heat and comfort,
OPOP s.r.o.
2. BOILER PROPERTIES
Courtesy of their design and surface treatment, the H4 series hot water steel boilers are
intended for level and central heating of detached houses with the maximum hydrostatic
height of 20 m. The boilers make it possible to combust solid fuels such as lignite and
wood.
Note: Primary combustion air supply via the stoking door must be adjusted
in order to allow combustion of wood. For this change to take place the heat insulation
(1 located on the bottom part of the stoking door must be removed and a controller
chain must be connected to the flap in the stoking door (2 . When combusting wood, the
choker stays completely in the ash pan door.

Heat and Comfort
3
Obr. – spalování uhlí – coal combustion; spalování d eva – wood
combustion
3. Technical escription
The upper part of the boiler consists of a stoking door fitted on hinges and a
cleaning door attached to the weldment by means of fly nuts. The door is sealed tightly
to the boiler body by a heat insulation rope. The actual boiler body is a welded structure
consisting of steel sheeting. Seen from above, it is divided by water partitions into three
parts:
a) the frontal space behind the front wall of the boiler forms a charging shaft with a
moving alloy grate;
b) the central part forms the combustion space complete with a chamotte shaped brick
provided in the upper part for improved combustion of flue gases;
c) the rear space forms a reverse draft, where the combustion gases flow to under the
bottom part of the last partition and subsequently ascend into the smoke bell. In the

Heat and Comfort
4
upper part of the space, there is a movable heating flap, which allows direct flue gas
removal from above to the bell.
The boiler fireplace is fitted with a movable cascade grate controlled by a lever on the
side of the boiler. The amount of secondary air supplied is manually adjustable for H4
boilers on both side shells of the boiler. Under normal operating conditions respecting
the nominal power, the flaps are fully open.
The boiler may be operated with both lignite (grain 1) and fuel wood at the maximum
length of 25cm for H412 and H418 boilers and 30cm for H424 and H430 boilers.
The ash pan door is fitted with a choker for combustion air control, coal combustion
and the stoking door is fitted with a choker for combustion air control, for wood
combustion with the use of an automatic combustion air controller. Whenever a change
in fuel occurs, adjustments must be effectuated, see the note in Page 1. In order to meet
the requirements of the ČSN EN 303-5 Standard (Central Heating Boilers Operated with
Solid Fuel with Manual or Automatic Feed, At Nominal Heat Generating Capacity of
Max. 300kW), the boiler must be operated in absence of an inserted ash pan drawer in
the ash-pan compartment; otherwise the ash-pan drawer must be emptied at increased
frequency.
The air supply and discharge flanges as well as the bell are located along the central
axis of the rear boiler part. In the upper part a 3/4" sleeve is provided for the connection
of the combustion air control and a 1/2" sleeve to place the anti-overheating safety
equipment sensor; in the lower part, there is a 1/2" sleeve provided for the discharge and
filling cock.
The walls of the boiler are heat insulted and covered by surface treated cover plates.
The stoking, cleaning and ash pan doors are made of surface treated parts and are heat
insulated. The temperature and pressure gauges are fitted in the cover plate, taking
temperature and pressure measurements of the heating water inside the boiler.

Heat and Comfort
5
4. Main imensions Table relating to Fig. 2
H 412
H 418
H 424
H 430
A – Total Boiler Height 865 865 865 1005
B – Total Boiler Depth 598 670 670 670
C – Boiler Width 386 386 490 490
D – Lo ation of the Gas Flue 635 635 635 755
E – Lo ation of the Supply Water
Sleeve
99 99 99 99
F – Lo ation of the water supply
sleeve
781 781 781 921
G – Flange Size 116 116 116 116
H – Flange S rew Spa ing 67 67 67 67
J – Boiler Base Depth 398 470 470 470
K – Boiler Base Width 316 316 420 420

Heat and Comfort
6
Fig. 1 - H412 Boilers

Heat and Comfort
7
Fig. 2: H418 Boilers

Heat and Comfort
8
Explanatory Notes:
1 – H418 Boiler Body
2 – Grating Mechanism
4 – Heat-up Flap
5 – Cleaning Stopper
9 – Grating Mechanism Lever
10 – Ash Pan Drawer
15 – Stoking Door
16 – Cleaning Door
17 – Ash Pan Door
19 – Movable Grate
20 – Inclining Grate
27 – Handle
33 – Frontal Cover
34 – Side Cover
37 – Cooling Loop
39 – Flange
41 – Automatic Combustion Air Controller
58 – M10,30 Screw
64 - M10 Nut
69 – 10.5 Washer
84 – 0-120°C Thermometer
85 – Fibrous Sealing
89 – 0-4 Bar Manometer

Heat and Comfort
9
Fig. 3: H424 Boilers

Heat and Comfort
10
5. Technical parameters for Coal table 2
H 412 H 418 H 424 H 430
Operating Flue (mbar) 0.18 0.18 0.22 0.27
Water Volume ( l ) 22.7 26 35 42
Bell Diameter (mm) 130 130 160 160
Boiler Hydrauli Loss at ∆T 20°/10° (mbar) 0,1/0,37
0,19/0,7
0,28/1,1
0,38/1,4
Boiler Class 2 2 2 2
Burning Time at Nominal Power (h) 4 4 4 4
Temperature Control Range (°C) max. 90
max. 90
max. 90
max. 90
Minimum Supply Water Temperature (°C) 65 65 65 65
Fuel Shaft Volume ( l ) 35 35 46 57
Filling Hole Size (mm) 182x308
182x308
182x412
182x412
Nominal Heat Generating Capa ity (kW) 14 19 24,5 30
Combustion Gas Temperature at
Nominal Heat Generating Capa ity
(°C) 355 353 349 345
Volume Flow of Combustion Gases at
Nominal Heat Generating Capa ity
(kg/s) 0,011 0,016 0,021 0,026
Effi ien y (%) 70 71 72 73
Operating Overpressure (bar) 2 2 2 2
Heating Surfa e (m2) 1.36 1.5 1.9 2.35
Boiler Weight (kg) 155 170 210 247
Fuel Consumption (kg/hour)
3,9 5,5 7,2 8.91
Type of Fuel and Fuel Water Content Lignite b2, H2O max. 20%
Fuel Size Grain
1
Technical Parameters for Wood table 3
Operating Flue (mbar) 0.18 0.18 0.22 0.27
Water Volume ( l ) 22.7 26 35 42
Bell Diameter (mm) 130 130 160 160
Boiler Hydrauli Loss at ∆T 20°/10° (mbar) 0,1/0,37
0,19/0,7
0,28/1,1
0,38/1,4
Boiler Class 1 1 1 1
Burning Time at Nominal Power (hour) 2 2 2 2
Temperature Control Range (°C) max. 90
max. 90
max. 90
max. 90
Minimum Supply Water Temperature (°C) 65 65 65 65
Fuel Shaft Volume ( l ) 35 35 46 57
Filling Hole Size (mm) 182x308
182x308
182x412
182x412
Nominal Heat Generating Capa ity (kW) 11 15,5 20 25
Combustion Gas Temperature at
Nominal Heat Generating Capa ity
(°C) 235 230 225 220
Volume Flow of Combustion Gases at
Nominal Heat Generating Capa ity
(g/s) 0,016 0,02 0,023 0,027
Nominal Heat Generating Capa ity/ min.
Heat Generating Capa ity
Effi ien y (%) 66,8 68,8 70,9 73
Operating Overpressure (bar) 2 2 2 2
Heating Surfa e (m2) 1.36 1.5 1.9 2.35
Boiler Weight (kg) 155 170 210 247
Fuel Consumption (kg/hour)
3,6 5 6,5 8