onga ECO800 Manual de usuario

OWNERS MANUAL
For the Installation, Operation and Service of the
Should the installer or owner be unfamiliar with the correct installation or operation of this type of
equipment you should contact the distributor/manufacturer for the correct advice before proceeding
with the installation or operation of this product. The pump operator or owner must be provided with
this owner’s manual.
TM
ECO800
Variable Speed Pool Pump
eco
8 0 0
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:32 AM

Onga and Pentair
Onga has been servicing the Australian and New Zealand markets with the highest quality water
movement products for just over 40 years. Established in 1967, Onga has a product to meet your
every water need.
Onga is part of the Pentair group, a global leader in swimming pool, spa and aquatic equipment.
The business has built a reputation as an innovation leader, providing high performance, reliable
and energy-efficient filters, controls, sanitizers, pumps, heaters, cleaners, and accessories for
residential and commercial pool owners and operators.
The Eco Select® brand identifies our most eco-friendly products
As the global leader in pool and spa equipment, we've made a strong commitment to develop and offer the
most environmentally responsible products available.
®
When you see the Eco Select brand on one of our products, you'll know it is our “greenest” and most
efficient product in that equipment category.
These products do the best job of saving energy, conserving water, reducing noise, or otherwise
contributing to a more environmentally responsible equipment system. In every case, a product that earns
the Eco Select brand is clearly our “greenest” and most efficient choice.
®
Eco Select
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:32 AM

Table of Contents
Features and Benefits
Technical Information
Model Data
Hydraulic Performance
Dimensions
Installation
Pump Positioning
Piping
Pool Outlets
Electrical
Equipotential Bonding
Operation
Priming the Pump
Speed Selection
Variable Speed Adjustment
Service & Maintenance
Troubleshooting
Troubleshooting Guide
Motor Flash Codes
Spare Parts
Page
3
4
5
5
6
6
7
7
7
8
9
9
10
11,12
13
14
4, 5
6
7
11,12,13
eco
8 0 0
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:32 AM

Features & Benefits
The Onga Eco800 is the ideal pump for new or existing pools. Utilising advanced hydraulic design and the
latest technology in permanent magnet, variable speed motors, the Onga Eco800 has the perfect
combination of efficiency and performance. The Onga Eco800 delivers energy savings and the power when
you need it. You will also have the peace of mind that you are doing your bit for the environment and
reducing your carbon foot print.
Variable speed pump, with 3 programmable speeds, allows you to effortlessly select the most
efficient setting to meet you filtration, cleaning and water feature needs.
Axial flux, brushless permanent magnet motor delivers high efficiency and low noise levels.
Fault protected motor prevents damage by automatically shutting down the motor in the event of a
locked rotor, under voltage, over voltage or over current condition and will automatically reduce the
speed during an over temperature condition.
Precision-fit internal components and superior hydraulic design deliver effortless performance,
energy savings and extended pump life.
A specially designed sound-dampening pump casing and base make pump operation incredibly
quiet.
Constructed of our durable, thermoplastic, composite resin, so you can be sure it will stand up to
the harshest conditions.
A heavy-duty construction and a motor rated for continuous operation make the Eco800 a tough,
long-lasting performer.
The high-capacity trap holds a large amount of debris, so you clean less often.
The Cam and Ramp™ lid is easy to remove and locks in place with a quarter turn, making inspection
and cleaning a breeze.
Quick-disconnect plumbing unions.
eco
8 0 0
3
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Technical Information eco
8 0 0
Model: ECO800
RPM: Low 1450RPM (default factory setting)
Med 2400RPM (default factory setting)
High 2800RPM (default factory setting)
Adjustable Range: 1000-2850RPM
Electrical Rating: 230-240V 50Hz single phase
Rated Current: Low: 1.3A (max)
Med: 4.4A (max)
High: 6.5A (max)
Input Power (P1): Low: 160W (max)
Med: 595W (max)
High: 940W (max)
Pump Power (P2): Low: 130W (max)
Med: 475W (max)
High: 750W (max)
Maximum Ratings: 2850RPM, P1 975W, P2 800W, 6.7A
IP Rating: IP25
Inlet (Suction): ABS Barrel Union to suit 50mm PVC pressure pipe
to AS/NZS 1477
Outlet (Discharge): ABS Barrel Union to suit 50mm PVC pressure pipe
to AS/NZS 1477
Max Working Pressure: 260 kPa
Water Temperature Range: 5°C – 40°C
Maximum Ambient temperature: 5 5°C
Recommended pH Range: 7.2 - 7.8 (Guide Only)
Sound Power Level (Lwa): Low: 57.5dB
Med: 65.2dB
High: 69.3dB
Motor: Axial flux, permanent magnet, DC
Protection: Mains over voltage, mains under voltage, over temperature,
under temperature, locked rotor, over current, phase disconnect.
Supply cord: 10A, H07RNF, 2m.
4
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Technical Information eco
8 0 0
Hydraulic Performance
Dimensions
Onga ECO800 Performance Chart
A 637mm
B 179mm
C 256mm
D 354mm
2800RPM
2600RPM
2400RPM
2200RPM
2000RPM
1800RPM
1600RPM
1450RPM
5
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
0.0
0.0 100.0 200.0 300.0 400.0 500.0
Head (m)
Flow (L/min)
2800RPM
2600RPM
2400RPM
2200RPM
2000RPM
1800RPM
1600RPM
1450RPM
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Installation eco
8 0 0
The pump must be installed and serviced by a suitably qualified person in order to avoid
hazard. Incorrectly installed or tested equipment may fail, causing severe injury or property
damage.
These instructions are a guide only. Should you the installer or owner of the product be
unfamiliar with the correct installation or operation of this product you should contact a
suitably qualified person for advice.
Do not connect system to high pressure or mains water system.
This pump is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the pump.
The Eco800 is electrically connected. Ensure that it is isolated from electrical supply during
installation and any subsequent service work.
For best performance, allow pump
suction inlet height to be as far
below water level as possible and
allow the use of short, direct suction
pipe with minimum bends (to reduce
friction losses).
1. Plan the position of the pump
a) Have enough ventilation to keep ambient temperature below the motor's rated ambient temperature whenever the pump
is running. If installed in an enclosure/pump house, the enclosure must have adequate ventilation (200sq.cm min, inlet &
outlet) and air circulation Allow 200mm to keep rear of motor clear.
b) Have adequate floor drainage to prevent flooding and be protected from excess moisture.
c) Be solid, level, rigid and vibration free.
d) To reduce vibration and pipe stress, bolt pump to mount. Fixing holes accept 12mm fasteners.
e) Be within 2m of a power outlet for electrical connection (refer to AS/NZS 3000 for rules regarding connection of
electrical equipment in pool zones).
f) Allow adequate access for servicing pump and piping.
2. Piping
For best performance, allow pump
suction inlet height to be as far
below water level as possible and
allow the use of short, direct suction
pipe with minimum bends (to reduce
friction losses).
a) Use only Australian Standard PVC pressure pipe. For best performance use at least 50mm diameter pipe for all
connections to the pump. Never use a suction pipe smaller than pump suction connections (50mm) and use larger pipe
for long suction distances.
b) To avoid stress on the pump, support both suction and discharge pipes independently. Place these supports as close to
the pump as possible.
c) To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump.
6
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Installation eco
8 0 0
3. Pool Outlets
a) The pump suction system must provide protection against hazard of suction entrapment or hair
entrapment/entanglement. The pool outlet piping must be in accordance with the latest AS1926.3 standard
b) Suction outlet covers and skimmers must have been tested and found to comply with the latest AS1926.3 standard or
ASME/ANSI specification for Suction Fittings.
4. Electrical
a) Electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) taking into account its ratings
(Class I, IPX5). The pump is supplied with a standard Australian 10 amp plug and 2 metres of cord. Select the correct
Pool Zone for installation.
b) An RCD with maximum rated residual current of 30mA is required for the power supply to the pump. Additionally, if a
suitable socket outlet is not available a weatherproof socket must be installed by an electrician in a suitable location.
RCD tripping indicates an electrical problem. If RCD trips and will not reset have a qualified electrician inspect and repair
electrical system.
c) Incorrect voltage can cause fire or seriously damage pump and voids warranty.
d) Voltage at pump must not be more than 6% above or 10% below motor nameplate rated voltage or pump may overheat,
causing overload tripping and reduced component life. If voltage is less than 90% or more than 106% of rated voltage
when pump is running at full load, consult the power company.
Do not use extension leads as they
are unsafe in and around the
Pool Zone.
Hazardous voltage. Can shock,
burn or cause death.
To avoid dangerous or fatal electrical
shock, turn OFF power to pump and
remove plug from outlet before
working on electrical connections.
5. Equipotential bonding
If equipotential bonding is required (refer to local statutes and regulations), connect all metal parts of the swimming pool or
spa structure and to all electrical equipment, metal conduit, and metal piping in accordance with the wiring rules. Run a
wire from the equipotential bonding terminal on the pump (bottom, left motor bolt with serrated washer) to the pool
bonding structure.
7
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Operation eco
8 0 0
NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding.
Fill pump with water before starting motor.
Freezing conditions will damage the unit, as water expands as it freezes. Ensure that the
Eco800 is located so that it is not prone to freezing, or ensure that the product is
disconnected and dried of water during cold conditions.
Trapped air in system can cause explosion. Ensure all air is out of the system before
operating or testing equipment
Fire and burn hazard. Modern motors run at high temperatures. To reduce the risk of fire,
do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid
burns when handling the motor, let it cool for at least 20 minutes before trying to work on
it.
Small children using pool must ALWAYS have close adult supervision
Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or
operate pump, pool/spas if a suction outlet cover is missing, broken, or loose. Follow the
guidelines below for a pump installation which minimises risk to users of pool and spas.
NEVER tighten or loosen trap lid while pump is operating.
It is not necessary to lubricate the o-
ring. The original equipment O-ring
contains a permanent internal
lubricant.
a) Before removing trap lid, SWITCH OFF POWER SUPPLY to pump.
b) CLOSE SHUT-OFF VALVES on suction and discharge pipes, if present.
c) Remove the trap lid (turn anti-clockwise)
d) Fill trap tank with water.
e) Check the lid o-ring and sealing surface, ensure there is no dust or debris on either, and replace the lid (turn clockwise to
tighten by hand only - no wrenches!).
f) Open the shut-off valves on the suction and discharge pipes, if present.
g) Release all air from filter, pump and piping system (refer filter owner's manual). In a flooded suction system (water
source higher than pump), pump will prime itself when suction and discharge valves are opened and air is released.
h) Switch on power to the pump to start.
I) Pump should start to prime now. Priming time will depend on vertical height of suction lift and horizontal length of
suction piping but is generally between 30 seconds to 3 minutes under normal installation conditions.
j) The Eco 800 will start slowly but ramp up to high speed for the first 2 minutes to assist priming. It will then switch to the
selected speed.
* Should the pump not prime, ensure that all valves are open, lint trap is clear of debris and suctions and suction pipe end is submersed
in water, and that there are no leaks in suction pipe. See troubleshooting guide.
1. Priming the pump
8
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:34 AM

Operation eco
8 0 0
2. Speed selection
Med
Low High
Speed / Application
Filtration and
water circulation
Cleaning with a
suction cleaner
Backwashing
filter.
Operating some
water features such
as jets or waterfalls.
Solar heating
The Onga Eco800 comes pre-programmed with the following default speeds:
1450RPM 2400RPM 2800RPM
Press for low speed Press for medium speed Press for high speed
Off button
Press to turn power on/off.
If power is removed, motor will return to the last speed selected when power is restored.
Motor will remember ON/OFF state.
3.Variable Speed Adjustment
If the default speed settings do not perfectly match the particular installation. They can be adjusted as follows.
1. , or Press and hold button corresponding to speed you wish to change.
Hold for 3 seconds and a light should begin to flash.
2.
To decrease speed by 50rpm increments with 1000rpm as the
minimum limit
Med
SET
Low
-
High
+
Low
-
High
+
To increase speed by 50rpm increments with 2850rpm as the
maximum limit
3.
Med
SET
To save the current speed setting and return to normal operation mode
Will cancel the change and revert back to the original speed and
return to normal operation mode
Med
SET
Low
-
High
+
+ + Holding all 3 buttons for 3 seconds will reset the speeds to default
9
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
0
5
25
75
95
100
Eco800_OM_final
Monday, 12 November 2012 9:13:35 AM
Tabla de contenidos
Otros manuales de Bomba de piscina de onga
Manuales populares de Bomba de piscina de otras marcas

Resol
Resol DeltaSol B Pro Manual de usuario

Evolution Aqua
Evolution Aqua UniTech Perfect 5000 Manual de usuario

Outside Living Industries
Outside Living Industries Ubbink Heatermax Pool Guía de inicio rápido

CPI
CPI Olympic 2P1815 Manual de usuario

Flotec
Flotec FP6121-01 Manual de usuario

Pentair
Pentair ONGA LEISURETIME LTP400 Manual de usuario