Omega DRN-PS-1000 Manual de usuario

http://www.omega.com
e-mail: [email protected]
®
UserÕs Guide
DRN-PS-1000
UNIVERSAL SWITCHING POWER SUPPLY
Compact DIN-Rail 24 Volt
USA
MADE
IN

Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047
TEL: (203) 359-1660 FAX: (203) 359-7700
e-mail: [email protected]
Canada: 976 Bergar
Laval (Quebec) H7L 5A1
TEL: (514) 856-6928 FAX: (514) 856-6886
e-mail: [email protected]
For immediate technical or application assistance:
USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA¨
Customer Service: 1-800-622-2378 / 1-800-622-BEST¨
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN¨
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Mexico TEL: (001)800-TC-OMEGASM FAX: (001) 203-359-7807
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands
TEL: +31 (0)20 6418405 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: [email protected]
Czech Republic: RudŽ arm‡dy 1868, 733 01 Karvin‡ 8
TEL: +420 (0)69 6311899 FAX: +420 (0)69 6311114
e-mail: [email protected]
France: 9, rue Denis Papin, 78190 Trappes
TEL: +33 (0)130 621 400 FAX: +33 (0)130 699 120
Toll Free in France: 0800406342
e-mail: [email protected]
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 TC-OMEGASM
e-mail: [email protected]
United Kingdom: One Omega Drive
ISO 9002 Certified River Bend Technology Centre
Northbank, Irlam
Manchester M44 5EX United Kingdom
TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in the UK: 0800 488 488
e-mail: [email protected]
OMEGAnetSM On-Line Service Internet e-mail
http://www.omega.com [email protected]
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly
pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability
for any errors it contains, and reserves the right to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for, patient connected applications.
This device is marked with the international caution symbol. It is important to read the Setup Guide before installing or
commissioning this device as it contains important information relating to safety and EMC.

1. General Information and Features 2
2. Safety Considerations 3
3. Installation and Removal 4
3.1 Installation Clearance 5
3.2 Mounting on DIN Rail 6
3.3 Removal of Unit 7
4. Input and Output Connections 8
4.1 Block Diagram 8
4.2 Wiring for 115 Vac - Single Phase 9
4.3 Wiring for 230 Vac - Two Phase 10
5. Specifications 11
Input Power 11
Output Power 11
General 12
Wire Connections 12
6. Dimensions 13
7. Temperature Derating Graph 14
CONTENTS
1

The compact DRN power supplies are designed to
supply well-regulated 24 volt DC power to sensors,
signal conditioners, data acquisition systems and
high level logic equipment.
Significant DRN features include:
¥ Tested isolation, primary to output
¥ Recessed live parts and connector screws
¥ Either 32mm or 35mm DIN rail mounting
¥ Wide input voltage tolerances
¥ Protective varistor input shunt
¥ Input AC spike rejection with LC filters
¥ LED power-on lamp
¥ Over-temperature protection
¥ Short circuit protection
¥ Low-ripple, well-regulated design
Features
GENERAL INFORMATION AND FEATURES
1
2

SAFETY CONSIDERATIONS
2
3
This device is marked with the international Caution symbol. It is
important to read this manual before installing or commissioning this
device as it contains important information relating to Safety and EMC
(Electromagnetic Compatibility).
Unpacking & Inspection
Unpack the instrument and inspect for obvious shipping damage. Do not attempt to
operate the unit if damage is found.
This instrument is a DIN rail mount device. Installation of this instrument should be done
by Qualified personnel. In order to ensure safe operation, the following instructions
should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the
building installation as a disconnecting device. It shall be marked to indicate this function, and it shall
be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker
shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements
of IEC 947Ð1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be
incorporated in the mains supply cord.
Furthermore, to provide protection against excessive energy being drawn from the mains supply in
case of a fault in the equipment, an overcurrent protection device shall be installed.
¥ The Protective Conductor must be connected for safety reasons. Check that the
power cable has the proper Earth wire, and it is properly connected. It is not safe to
operate this unit without the Protective Conductor Terminal connected.
¥ Do not exceed voltage rating on the label located on the top of the instrument
housing.
¥ Always disconnect power before changing signal and power connections.
¥ Do not use this instrument on a work bench without its case for safety reasons.
¥ Do not operate this instrument in flammable or explosive atmospheres.
¥ Do not expose this instrument to rain or moisture.
¥ Unit mounting should allow for adequate ventilation to ensure instrument does not
exceed operating temperature rating.
¥ Use electrical wires with adequate size to handle mechanical strain and power
requirements. Install without exposing bare wire outside the connector to minimize
electrical shock hazards.
EMC Considerations
¥ Whenever EMC is an issue, always use shielded cables.
¥ Never run signal and power wires in the same conduit.
¥ Use signal wire connections with twisted-pair cables.
¥ Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems
persist.

If a rail assembly is to be transported, then
disconnection, dismounting and separate
packing of the power supply is
recommended.
For units that must be shipped installed on
the rail, additional bracing to resist
transportation shocks is recommended.
Do not attempt to install or connect to the
power supply when the mains are
energized.
Warning!
INSTALLATION AND REMOVAL
3
4

3.1 Installation Clearance
Ensure that there is enough room for mounting the power
supply unit. There should be a minimum of 1" [25mm] spacing
to allow sufficient air circulation for proper cooling.
Figure 3.1 Ñ Mounting
INSTALLATION AND REMOVAL
3
5
Signal Conditioner
Modules Power Supply
24V-Bus
1" 1"

3.2 Mounting on DIN Rail
To install unit onto DIN Rail
1. Tilt unit position mounting guide onto DIN Rail, as shown.
2. Push unit towards DIN Rail and it will snap into place.
Figure 3.2
Ñ
Mounting on 35mm DIN Rail
Figure 3.3
Ñ
Mounted on 32mm DIN Rail
INSTALLATION AND REMOVAL
3
6
35mm Rail
Mounting Guide
1. Tilt
2. •Push to
• Snap on
32mm Rail

3
7
3.3 Removal of Unit
The mounting guide can remain on DIN Rail and Power
Supply can be removed.
1. While holding mounting guide, push unit upwards and unit
will detach from mounting guide.
Figure 3.4
Ñ
Removal of Unit
Figure 3.5
Ñ
Unit Removed
INSTALLATION AND REMOVAL
Mounting Guide
CASE
TAB MUST
BE LOCATED
AT BOTTOM.
35mm (SHOWN)
or 32mm DIN RAIL
Hold Guide Push Up
35mm Rail

4
8
4.1 Block Diagram of Power Supply
Figure 4.1 Ñ Block Diagram
4.2 Wiring
Warning: Do not turn on the ac power to the power supply
unit until you have completed all output connections. Failure
to do so may result in injury!
This device must only be installed electrically by a specially
trained electrician with corresponding qualifications.
Warning: To avoid potential electric shock use National
Electrical Code (NEC) safety practices when wiring and
connecting this unit to a power source.
INPUT AND OUTPUT CONNECTIONS
Tabla de contenidos
Otros manuales de Fuente de alimentación de Omega

Omega
Omega ACC-PS1 Manual de usuario

Omega
Omega PSU-93 Manual de usuario

Omega
Omega LDX-4 Manual de usuario

Omega
Omega HB1700S Manual de usuario

Omega
Omega DP6-MLPS1 Manual de usuario

Omega
Omega FAR-2 Series Manual de usuario

Omega
Omega Omega Pro 80600 Instrucciones de uso

Omega
Omega PST-4130 Manual de usuario

















