Olympus IX2-DICD Manual de usuario

INSTRUCTIONS
IX2-DICD
This instruction manual is for the Olympus DIC Condenser Model IX2-DICD. To ensure the safety, obtain
optimum performance and to familiarize yourself fully with the use of this equipment, we recommend
that you study this manual thoroughly before operating the system. Retain this instruction manual in an
easily accessible place near the work desk for future reference.
A X 7 3 5 9
DIC CONDENSER
ax7359_cover.pmd 20.04.2005, 12:121

IX2_dicd_GB_cover.pmd 17.07.2009, 08:362

IMPORTANT — Be sure to read this section for safe use of the equipment. — 1-2
IX2-DICD
CONTENTS
3-1 Brightfield Observation ..........................................................................................................................................................................................................................14
3-2 DIC Observation .................................................................................................................................................................................................................................... 14-17
1 NOMENCLATURE 3-4
4 TROUBLESHOOTING GUIDE 18
2 ASSEMBLY 5-13
3 OBSERVATION METHODS 14-17
5 SPECIFICATIONS 19
1Cross-Nicol Adjustment 2Observation Procedure
ax7359_contents.pmd 20.04.2005, 12:121

1
IMPORTANT
· This product is a slim, single type condenser that can be combined with a top lens matching the desired observation (dry,
oil-immersed or water-immersed).
· The water-immersed top lens (IX2-TLW) features an NA of 0.9, WD or 3.7 mm and manipulator access angle of 40°. In high-
resolution DIC (Differential Interference Contrast) observation, these features allow injection operation to be performed
simultaneously.
1Getting Ready
1. This manual pertains only to the DIC condenser. Please also read the instruction manual for the IX2 series (IX81/IX71/IX51)
or IX series (IX70/IX50) microscope to understand the comprehensive operating instructions of the microscope system.
2. The DIC condenser is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact.
3. Be careful not to leave dirt or fingerprints on the lens components.
4. The stopper mechanisms provided for the functions indicate the limits of motion. Never attempt to go beyond a stopper
by applying excessive force.
5. When the PlanApoN60X, UPlanSApo60XO, PlanApo60XO3 and U-DICTHC are combined, (using the U-DIC60HC or U-
DPO60HC DIC prism), color irregularities may be noticeable with certain specimens. Due to this, it is recommended to use
a photo lens (PE3.3X or with a higher magnification) in photomicrography.
6. Do not tighten the clamping screws of the DIC prism and slider too much.
2Maintenance and Storage
1. To clean the lenses and other glass components, simply blow dirty away using a commercially available blower and wipe
gently using a piece of cleaning paper (or clean gauze). If a lens is stained with fingerprints or oil smudges, wipe it gauze
slightly moistened with commercially available absolute alcohol.
Since the absolute alcohol is highly flammable, it must be handled carefully. Be sure to keep it away from open
flames or potential sources of electrical sparks -- for example, electrical equipment that is being switched on or off.
Also remember to always use it only in a well-ventilated room.
2. Never attempt to disassemble any part of the equipment, for this may degrade the performance.
IX2_dicd_GB_inst.pmd 17.07.2009, 08:291

IX2-DICD
2
If the condenser is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the
equipment may also be damaged. Always use the system as outlined in this instruction manual.
The following symbols are used to set off text in this instruction manual.
: Indicates that failure to follow the instructions in the warning could result in bodily harm to the
user and/or damage to equipment (including objects in the vicinity of the equipment).
# : Indicates that failure to follow the instructions could result in damage to equipment.
} : Indicates commentary (for ease of operation and maintenance).
3Caution
IX2_dicd_GB_inst.pmd 17.07.2009, 08:292

3
NOMENCLATURE
DIC Condenser
IX2-DICD
Polarizer clamping knob
Polarizer rotation dial
Aperture iris diaphragm
lever
DIC prism slider
(x 2 provided)
Knob
(Detachable)
Condenser height fine
adjustment knob
Polarizer engagement knob
Slider clamping knob
DIC prism slider insertion slot
Top lens mount
DIC prism/slider clamping knob
IX2_dicd_GB_inst.pmd 17.07.2009, 08:293

IX2-DICD
4
Dry Top Lens
U-TLD Oil-Immersed Top Lens
U-TLO Water-Immersed Top Lens
IX2-TLW
DIC Prism
See the applicable objective
list (pages 7 to 12).
DIC Slider
U-DICT
U-DICTS
U-DICTHC
U-DICTHR
Prism position selector lever*
Pushed in: BFP1
Pulled out: NORMAL
Prism movement knob
*This lever is not provided for the U-DICT.
IX2_dicd_GB_inst.pmd 17.07.2009, 08:294

5
ASSEMBLY
2-1 Attaching the Top Lens
}According to the desired observation, attach the dry (U-TLD), oil-immersed
(U-TLO) or water-immersed (IX2-TLW) top lens to the DIC condenser.
1. The U-TLD or U-TLO top lens @ can be attached by screwing it clockwise
into the top lens mount ².
2. To attach the IX2-TLW top lens, turn the top lens mount ² counterclock-
wise to remove it and screw in the top lens into the position of the top lens
mount.
Precautions on Oil-Immersed Top Lens
#When a slide glass with thickness of 1.2 mm or more is used, the field
iris diaphragm image may not be observed.
#Use an objective with 20X or higher power.
Fig. 1
²
@
IX2_dicd_GB_inst.pmd 17.07.2009, 08:295

IX2-DICD
6
Fig. 2
Fig. 3
2-2 Attaching the DIC Prism
}In the DIC prism slider, mount the DIC prism matching the objective, DIC
slider and top lens in use. (For the combination list, see pages 7 to 12.)
Procedure (Figs. 2 & 3)
#To ensure the optical performance, do not tighten the clamping screws
@ and | too much.
1. Loosen the two clamping screws @ by inserting the DIC prism/slider
clamping knob provided with the DIC condenser into each of them.
2. Align the positioning pin of the DIC prism ² with the groove on the slider,
drop the DIC prism into the slider and tighten the two clamping screws @.
3. Turn the DIC prism slider ³ by 180° and insert it into the condenser. Tighten
the slider clamping screw | using the DIC prism/slider clamping knob.
}If the knob ƒ on the DIC slider comes in the way, remove the knob by
turning it counterclockwise.
²
@
|
³
ƒ
IX2_dicd_GB_inst.pmd 17.07.2009, 08:296

7
Combinations of Objectives, DIC Sliders, Top Lenses and DIC Prisms
To be used in the BFP1 position of the DIC slider.
DIC Slider U-DICT U-DICTS (Shift type)
Top Lens U-TLD/IX2-TLW U-TLO U-TLD/IX2-TLW U-TLO
UPlanFLN 10X2 U-DIC10 --- U-DIC10 ---
20X U-DIC20 U-ODIC20 U-DIC20 U-ODIC20
40X U-DIC40 U-ODIC40 U-DIC40 U-ODIC40
40XO --- --- U-DIC40 U-ODIC40
60X U-DIC60 U-ODIC60 U-DIC60 U-ODIC60
60XOI
UPlanSApo 10X2 U-DIC10 --- U-DIC10 ---
20X U-DIC20 U-ODIC20 U-DIC20 U-ODIC20
20XO
40X2 U-DIC40 U-ODIC40 U-DIC40 U-ODIC40
60XO --- --- U-DIC60 U-ODIC60
60XW U-DIC60 U-ODIC60 U-DIC60 U-ODIC60
100XO U-DIC100 U-ODIC100 U-DIC100 U-ODIC100
PlanApoN 60XO --- --- U-DIC60 U-ODIC60
UIS2 Series
100XO2 U-DIC100 U-ODIC100 U-DIC100 U-ODIC100
100XOI2
LUCPlanFLN 20X U-DIC20 U-ODIC20 U-DIC20 U-ODIC20
40X U-DIC40 U-ODIC40 U-DIC40 U-ODIC40
60X U-DIC60 U-ODIC60 U-DIC60 U-ODIC60
IX2_dicd_GB_inst.pmd 17.07.2009, 08:297
Tabla de contenidos
Manuales populares de Bomba de calor de otras marcas

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manual de usuario

Dimplex
Dimplex LI 16I-TUR Guía del usuario

Carrier
Carrier WSHP Open v3 Guía de configuración rápida

TGM
TGM CTV14CN018A Manual de usuario

Carrier
Carrier 38MGQ Series Manual de usuario

Kokido
Kokido K2O K880BX/EU Guía de solución de problemas

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Guía rápida

Carrier
Carrier 48EZN Manual de usuario

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Instrucciones de funcionamiento

Ariston
Ariston NIMBUS Manual de usuario

Weishaupt
Weishaupt WWP L 7 Guía del usuario

GE
GE Zoneline AZ85H09EAC Manual de usuario