OCTO PurePlace Building Pro Manual de usuario

PurePlace Building Pro
USER MANUAL

OCTO PurePlace uses the advanced AFLPCO®* Photocatalytic Oxidation
method to sanitise surfaces and clean the air. Both effective and harmless,
OCTO PurePlace is derived from enhanced aerospace technology (NASA
patent released on public domain) and can eliminate viruses, bacteria, fun-
gi as well as odours and volatile organic compounds.
*AFLPCO® is proprietary technology of Air For Life UK LTD.
PurePlace Building Pro

PUREPLACE BUILDING PRO3
USER MANUAL
Thank You For Choosing
OCTO PurePlace Building PRO
Congratulations, you own the most advanced photocatalytic air purification sy-
stem available! Before operating the AFL system please read this manual in its
entirety. Doing so will give you important information to keep you safe from harm
and ensure you get the most benefit from your AFL air purification system.
The AFL air purification system provides you with NASA developed technology at
its best. More than 20 years after NASA put the first man on the moon, they deve-
loped a technology to aid in keeping astronauts healthy on space missions. AFL
enhanced the original NASA developed Ethylene Scrubber technology making it
far superior to any other product available in our industry. This enhanced patent
pending AFLPCO™ technology, originally developed by NASA, utilises a reaction
chamber coated with a new generation catalysts that is permanently bonded to
the reactor cell structure.
When photons from the germicidal UVC lamp excites water and oxygen mole-
cules on the catalyst surface, redundant oxidizers, including hydroxyl radicals,
are formed. Any organic com-pound that collides with the catalyst is instantly
eradicated. Not only does this effectively eliminate ethylene gas, it has also been
proven to eradicate volatile organic compounds (VOCs), viruses, bacteria, fungi,
mould, and odours. AFL’s green technology is extremely energy & cost efficient.
From health care, to travel, to food preservation and more AFL protects you.

PUREPLACE BUILDING PRO
USER MANUAL
Table of Contents
Important safety instructions......................................................................5
Features and Benefits.........................................................................................9
Technology................................................................................................................... 11
Controls and Status Panel........................................................................... 12
Air Inlet and Outlet.............................................................................................. 14
Power Adapter......................................................................................................... 14
Outer Housing.......................................................................................................... 15
Base Plate.................................................................................................................... 15
Green AFLPCO™ Cell Access Panel................................................ 15
Placement and Installation ......................................................................... 15
Initial Start Up .......................................................................................................... 21
Maintenance............................................................................................................. 22
Standard Warranty Declaration............................................................. 28
Trouble Shooting Guide................................................................................ 30
Product Specifications.................................................................................... 31
Environmental Protection ............................................................................ 31

PUREPLACE BUILDING PRO5
USER MANUAL
For your safety and to ensure proper use
carefully read the entire contents of this
manual before operating the AFL unit.
IMPORTANT SAFETY INSTRUCTIONS
When operating any electrical appliance basic, precautions should always
be followed for safety.
RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
>
Carefully read the entire contents of this manual.
>
Do not use outdoors, in moist areas or on wet surfaces.
>
Do not use the unit in areas of extreme heat or in the presence of flam-
mable gas.
>
Do not allow any foreign objects to enter the air intake or outlet. Do not
place any object over the air intake or outlet.
>
Do not attempt to service or repair the unit yourself. Any attempt to
repair the unit yourself could cause serious injury and will void the
warranty.
>
Do not handle the plug or appliance with wet hands.
>
Do not pull on power cord to unplug. To unplug grasp the plug, not the
cord.
>
Do not use with damaged power cord or plug. If appliance is not wor-
king properly, has been dropped, damaged, left outdoors, or dropped
into water, call a local customer a customer service representative at
WARNING: RISK OF ELECTRICAL SHOCK. CAN CAUSE INJURY OR DE-
ATH. UNPLUG OR DISCONNECT UNIT FROM POWER SUPPLY BEFORE
SERVICING.

PUREPLACE BUILDING PRO6
USER MANUAL
Store and transport -20˚ C ~ 80˚ C, humidity 10% ~ 90% (Non Con-
densing).
Do not operate unit in ambient temperatures above 40˚ C.
KEEP OUT OF REACH OF CHILDREN
Only use the power adapters included with the AFL purification sy-
stem.
WARNING: UV LIGHT HAZARD. Harmful to skin and eyes. Can cau-
se temporary loss of vision. Never look at the lamp while illuminated.
To prevent exposure to ultraviolet light, be sure the power is discon-
nected before servicing. The Green AFLPCO™ Cell has been desi-
gned to minimize exposure to UV light. Power to the cell will automati-
cally disconnect when removed from the purifica-tion system
UV lamp contains Hg (Mercury) and should be disposed of according
to disposal laws. Find dis-posal centers at www.earth911.org.
Never touch UV lamp. Oils from your skin can cause UV lamp to break
when illuminated.
Never remove the outer housing of the AFL purification system.

PUREPLACE BUILDING PRO7
USER MANUAL
2
ELECTROMAGNETIC COMPATIBILITY
Medical Electrical equipment needs special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided in the
documents accompanying the equipment. Portable and mobile RF communication equipment can aect Medical Electrical Equipment. Use of a power cord other than the cord supplied may results in
increased emissions or decreased immunity of the System.
GUIDANCE AND MANUFACTURER’S DECLARATION - ELECTROMAGNETIC EMISSIONS
The System is intended for use in the electromagnetic environment specied below. The customer or the user of the System should assure that it is used in such an environment.
EMISSIONS TEST COMPLIANCE ELECTROMAGNETIC ENVIRONMENT - GUIDANCE
RF Emissions
CISPR 11 Group 1
The System uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any
interference in nearby electronic equipment.
RF Emissions
CISPR 11 Class B The System is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage
power supply network that supplies buildings used for domestic purposes.
Harmonic Emissions
IEC 61000-3-2 Class B
Voltage uctuations/icker emissions
IEC 6100-3-3 Complies
WARNING: This System should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the System should be observed to verify normal
operation in the conguration in which it will be used.
RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS AND THE SYSTEM
The System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the System can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the System as recommended below, according to the maximum output power of the
communications equipment.
RATED MAXIMUM OUTPUT
POWER OF TRANSMITTER
(W)
SEPARATION DISTANCE ACCORDING TO FREQUENCY OF TRANSMITTER (M)
150 kHz to 80 MHz
d=√1.2
80 MHz to 80 MHz
d=√1.2
800 kHz to 2.5 GHz
d=√2.3
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
11.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter,
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 - At 80 MHz and 800 MHz , the separation distance for the higher frequency range applies.
NOTE 2 - These guidelines may not apply in all situations. Electromagnetic propagation is aected by absorption and reection from structures, objects and people.

PUREPLACE BUILDING PRO8
USER MANUAL
3
GUIDANCE AND MANUFACTURER’S DECLARATION - ELECTROMAGNETIC IMMUNITY
The System is intended for use in the electromagnetic environment specied below. The customer or the user of the System should assure that it is used in such an environment.
IMMUNITY TEST IEC 60601 TEST LEVEL COMPLIANCE LEVEL ELECTROMAGNETIC ENVIRONMENT - GUIDANCE
Electrostatic discharge (ESD)
IEC 61000-4-2
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concrete, or ceramic tile. If oors are covered with synthetic material, the
relative humidity should be at least 30%.
Electrical fast transient/burst
IEC 61000-4-4
±2 kV for power supply lines
±1 kV for input/ output lines
±2 kV for power supply lines
±1 kV for input/ output lines
Mains power quality should be that of a typical commercial or hospital environment.
Surge
IEC 61000-4-5
±1 kV dierential mode
± kV common mode
±1 kV dierential mode
± kV common mode
Mains power quality should be that of a typical commercial or hospital environment.
Voltage dips, short interruptions,
and voltage variations on power
supply input lines
IEC 61000-4-11
<5% UT(>95% dip in UT) for
0.5 cycle
40% UT(60% dip in UT) for 5
cycles
70% UT(30% dip in UT) for 25
cycles
<5% UT(>95% dip in UT) for
5 sec
<5% UT(>95% dip in UT) for
0.5 cycle
40% UT(60% dip in UT) for 5
cycles
70% UT(30% dip in UT) for 25
cycles
<5% UT(>95% dip in UT) for
5 sec
If the System shuts down due to power mains interruption, user should discontinue device activa-
tion and refer to the IFU/Operating manual for furthers information.
Power frequency (50/60 Hz)
magnetic eld
IEC 61000-4-8
3 A/m 3 A/m Power frequency magnetic elds should be at levels characteristic of a typical location in a typi-
cal commercial or hospital environment.
RECOMMENDED SEPARATION DISTANCE
Conducted RF
IEC 61000-4-6
3 Vrms 150 KHz to 80 MHz 3 Vrms d = 1.2 √P
d = 1.2 √P 80 MHz to 800 MHz
Radiated RF
IEC 61000-4-3
3 V/m 80 MHz to 2.5 GHz 3 V/m d = 2.3 √P 800 MHz to 2.5 GHz
where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufac-
turer and d is the recommended separation distance in meters (M).
Field strengths from xed RF transmitters, as determined by an electromagnetic site survey*, should be less than
the compliance level in each frequency range**.
Interference may occur in the vicinity of equipment marked
with the following symbol.
NOTE 1 - UT is the a.c. mains voltage prior to application of the test level
NOTE 2 - At 80 MHz and 800 MHz the higher frequency range applies.
NOTE 3 - These guidelines may not apply in all situations. Electromagnetic propagation is aected by absorption and reection from structures, objects, and people.
* Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be
predicted theoretically with accuracy. To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic site survey should be considered. If the measured eld strength in the
location in which the System is used exceeds the applicable RF compliance level above, the System should be observed to verify normal operation. If abnormal performance is observed, additional mea-
sures may be necessary, such as reorienting or relocating the System.
** Over the frequency range 150 kHZ to 80 MHz, eld strengths should be less than 3 V/m.

PUREPLACE BUILDING PRO9
USER MANUAL
Features and Benefits
EASY OPERATION
OCTO PurePlace Building Pro gives you the option of both a high or low
setting, placing you in control of yourunique situation. The unit is designed
to operate continuously and should remain in operation 24 hours a day, 7
days a week for best results.
WALL MOUNTABLE
The OCTO PurePlace Building Pro comes complete with wall mounting har-
dware. Theft resistant mounting is standard on each unit.
LOW MAINTENANCE
There is virtually no maintenance to perform. Our proprietary long life Gre-
en AFLPCO™ Cell, complete with UVC lamps installed, should be replaced
every two years. The stainless steel dust guards require debris removal
periodically to ensure adequate air flow.
ENERGY EFFICIENT GREEN TECHNOLOGY
The OCTO PurePlace Building Pro is one of the most energy efficient gre-
en air purification systems available. Other brands require several hundred
watts to operate. OCTO PurePlace Building Pro requires only 33 watts of
electricity.
PROPRIETARY AFLPCO CATALYST
Every unit utilizes our proprietary TiO2 AFLPCO™ catalyst. Our catalyst
not only utilises TiO2, but other extremely effective catalyst metals in nano
size particles blended with a special hydrating agent to provide unparal-
leled results. This technology is so effective that it reduces any organic
compound including mould, bacteria, viruses, odours, VOCs, ethylene and
more.

PUREPLACE BUILDING PRO10
USER MANUAL
PROPRIETARY UVC LAMPS
At the core of the Green AFLPCO™ Cell are two proprietary UVC lamps.
The 254 nm germicidal lamps destroy mould, bacteria and viruses quickly.
They are American made lamps that utilize a proprietary long life coating
doubling the average life to two years. Our lamps also utilize two-tube line-
ar technology that protects against breakage and mercury leakage, abrupt
temperature changes, and high moisture.
MADE IN USA QUALITY
OCTO PurePlace Building Pro is made in America with quality American
engineered parts. From durable light weight anodized aluminum plates
down to the small stainless steel washable dust guards, every part of the
OCTO PurePlace Building Pro is made with pristine quality and assembled
by hand in the USA.
Tabla de contenidos
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario