SINGLE SIDED FIREPLACES:
SPECIFICATIONS & PRODUCT GUIDE

PAGE 2
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
1. NOTES
The appliance must be installed in accordance with the ORTAL AU/NZ Installation Manual.
The appliance must be properly connected to an approved chimney venting system. Refer to the specific appliance
installation guide to determine vent size and pathway requirements. In addition, adhere to the following pre-
installation guidelines:
• Use an approved DuraVent flue system as specified
• Consult the relevant authority to determine the need for a permit prior to starting the installation.
• It is the responsibility of the installer to ensure that this fireplace is installed in compliance with the
manufacturer’s instructions and all the applicable building codes. Contact your local distributor / dealer for correct
flue and flue termination information.
• Always used a licensed gas fitter / plumber to install the appliance
IMPORTANT:
THIS IS NOT AN INSTALLATION MANUAL. PLEASE
REFER TO THE DETAILED INSTALLATION MANUAL
DELIVERED WITH THE APPLIANCE.

PAGE 3
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
2. SPECIFICATIONS
MODEL BURNER
TYPE
INJECTORS NOMINAL GAS
CONSUMPTION
INLET
PRESSURE
MANIFOLD
PRESSURE
TURNDOWN
PRESSURE
FLUE SIZE
75 x 65 B45 Marked 650: with
7x0.950mm orifice
26MJ/h 1.13kPA 0.82kPA 0.23kPA 107/164mm
60 x 80 B45 Marked 650: with
7x0.950mm orifice
26MJ/h 1.13kPA 0.82kPA 0.23kPA 107/164mm
75 B45 Marked 650: with
7x0.950mm orifice
26MJ/h 1.13kPA 0.82kPA 0.23kPA 107/164mm
TRAD 90 B45 Marked 650: with
7x0.950mm orifice
26MJ/h 1.13kPA 0.82kPA 0.23kPA 125/205mm
110 / 110H B100 Marked 1200: with
7x1.275mm orifice
37MJ/h 0.69kPA 0.73kPA 0.26kPA 125/205mm
TRAD 110 B100 Marked 1200: with
7x1.275mm orifice
37MJ/h 0.69kPA 0.73kPA 0.26kPA 125/205mm
130 / 130H B100 Marked 1200: with
7x1.275mm orifice
37MJ/h 0.69kPA 0.73kPA 0.26kPA 125/205mm
150 / 150H B135 Marked 1200: with
7x1.275mm orifice
Marked 1400: with single
3.9mm orifice
55MJ/h 1.13kPA 0.61kPA 0.22kPA 125/205mm
170 / 170H B135 Marked 1200: with
7x1.275mm orifice
Marked 1400: with single
3.9mm orifice
55MJ/h 1.13kPA 0.61kPA 0.22kPA 125/205mm
200 / 200H B160 Marked 800: with
7x1.05mm orifice
Marked 1400: with single
3.8mm orifice
52MJ/h 1.13kPA 0.50kPA 0.22kPA 125/205mm
250 / 250H B160 Marked 800: with
7x1.05mm orifice
Marked 1400: with single
3.8mm orific
52MJ/h 1.13kPA 0.50kPA 0.22kPA 125/205mm

PAGE 4
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
3. DIMENSIONS
A B
C
MODEL
(all measurements in mm)
A
WIDTH
B
DEPTH
C
HEIGHT
GLASS SIZE
75 x 65 872 420 966 778 x 650
60 x 80 644 420 1070 552 x 740
75 856 420 751 748 x 440
TRAD 90 1036 637 955 900 x 804
110 1193 420 692 1108 x 350
110 H 1216 420 892 1108 x 550
TRAD 110 1227 637 1036 1085 x 868
130 1368 420 692 1278 x 350
130 H 1368 420 892 1278 x 550
150 1636 420 692 1528 x 350
150 H 1636 420 892 1528 x 550
170 1813 420 692 1528 x 350
170 H 1813 420 892 1528 x 550
200 2076 420 692 1968 x 350
200 H 2076 420 892 1968 x 550
250 2550 420 692 2444 x 400
250 H 2550 420 892 2444 x 550
Note: Minimum height off of the floor for all front facing Ortal fireplaces is 210mm.
Appliance legs must not be removed.
TRAD 90 and TRAD 110 are supplied without legs andshould be installed on 16mm Villaboard when
installed on a combustable floor.

PAGE 5
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
4. FRAMING & CLADDING
MODEL
(all measurements in mm) A B C D
60 x 80 222 778 475 1092
75 x 65 222 1005 473 989
75 222 989 473 773
110 254 1349 475 715
110H 254 1367 475 915
130 254 1519 475 715
130H 254 1519 475 915
150 254 1770 475 715
150H 254 1770 475 915
170 254 1970 475 715
170H 254 1970 475 915
200 254 2210 475 715
200H 254 2210 475 915
250 254 2683 475 764
250H 254 2683 475 915
TR90 254 1170 689 978
TR110 254 1360 689 1059
CLADDING FOR METAL STUDS
external cladding
The framing structure must be clad externally with non
combustible material and gaps sealed with a non-combustible fire
proof sealant. We recommend the fireplace to be in position and
flued prior to cladding.
OPTION 1: METAL STUDS FRAMING (Preferred option)
The frame must be designed to carry the entire weight of the finished wall with no component being supported by the fireplace.
CLADDING
REQUIREMENTS
ARE DIFFERENT
FOR TIMBER STUD
AND METAL STUD
FRAMING. PLEASE
READ INSTRUCTIONS
CAREFULLY BEFORE
FRAMING.

PAGE 6
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
4. FRAMING & CLADDING
MODEL
(all measurements in mm) A B C D E
60 x 80 222 778 475 1092 457
75 x 65 222 1005 473 989 560
75 222 989 473 773 510
110 254 1349 475 715 568
110H 254 1367 475 915 495
130 254 1519 475 715 568
130H 254 1519 475 915 495
150 254 1770 475 715 568
150H 254 1770 475 915 495
170 254 1970 475 715 568
170H 254 1970 475 915 495
200 254 2210 475 715 568
200H 254 2210 475 915 495
250 254 2683 475 764 519
250H 254 2683 475 915 495
TR90 254 1170 689 978 743
TR110 254 1360 689 1059 662
CLADDING FOR TIMBER STUDS WITH METAL SECTION
external cladding
internal cladding
OPTION 2: TIMBER STUDS WITH METAL SECTION
The frame must be designed to carry the entire weight of the finished wall with no component being supported by the fireplace.
The framing structure must be clad internally and externally
with non combustible material and gaps sealed with a non-
combustible fire proof sealant. We recommend the fireplace to be
in position and flued prior to framing/cladding.
We recommend using 16mm Gypsum fire rated plasterboard or its
equivalent for the enclosure of the fireplace chase.
CLADDING
REQUIREMENTS
ARE DIFFERENT
FOR TIMBER STUD
AND METAL STUD
FRAMING. PLEASE
READ INSTRUCTIONS
CAREFULLY BEFORE
FRAMING.

PAGE 7
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
5. VENTING
VENTING (convection air intake)
For mesh units:
- No need to create a convection air intake as the appliance is designed to supply fresh
air though the viewing panel.
For double glass units:
- Convection air intake vents are required at the bottom of the cavity and can be placed
at the front, side or back of the cavity.
SCREEN HEAT BARRIER -
GAP HEAT RELEASE
DOUBLE GLASS HEAT BARRIER -
REVEAL HEAT RELEASE
AIR INTAKE AS
REVEAL/TOE KICK
DIRECT VENT
EXHAUST AND
AIR INTAKE
HOT AIR FLOW
HEAT RELEASE
AS REVEAL
VENTING (Convection air outlet)
A convection air outlet is required for all Ortal fireplaces. This allows for heat building up within the fireplace cavity to
be released back into the space, helping to keep the cavity walls cool. It must be located at the top of the fireplace cavity
and be placed at a maximum of 150mm below the cavity ceiling. The vent can be located on the front, sides or back of
the fireplace cavity, as long as it releases into an interior space and not outdoors.
These are minimum requirements and the surface can be greater if desired.
MODEL Heat release vent
(min surface)
60 to 130 0.08m2
150 to 200 0.13m2
250 0.16m2

PAGE 8
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
ACCESS
PANEL
FIRE
6. ACCESS PANEL
Access panels are recommended for all ORTAL fireplaces. They allow efficient and
comfortable access to the fireplace receiver and valves, which is required for servicing
purpose.
Access panels can designed and positionned to minimise their visual impact as long as
access to the valves and receiver is maintained. The size of the access panel may vary,
but in all cases must allow the fireplace technician to effectively conduct a services. We
recommend a minimum size of 200x200mm.
However, access panels are not the only option for servicing the fireplace operation
mechanisms. A technician may also service the fireplace controls by going through the
firebox. This procedure requires removing the glass panel(s), taking out the interior
media and lifting the grill, burner and bottom side (explosion valve) of the unit. The
technician would then return all these fireplace components when service is complete.
The servicing procedure will take longer than through an access panel.
Fireplace installers are advised to consult with their clients, project architects or interior
designers regarding the advantages and disadvantages of each service option.

PAGE 9
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
7. TV CLEARANCES
305mm MIN 305mm MIN
RECESSED INSTALLATION FLUSH INSTALLATION

PAGE 10
OBLICA | SPECIFICATIONS AND PRODUCT GUIDE
8. TESTING
THE ORTAL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN
TESTED AND APPROVED BY AGA & IAPMO-R&T FOR USE WITH NATURAL
GAS (NG).
Australian Standard AS5263-0:2016 - Decorative Gas Log and Other Fuel Effect Appliances
Patent Pending for screen barrier glass bracket: USSN 60/040,074
Este manual sirve para los siguientes modelos
16
Tabla de contenidos
Otros manuales de Chimenea de interior de Oblica

Oblica
Oblica Skantherm Turn Manual de usuario

Oblica
Oblica PaxFocus Manual de usuario

Oblica
Oblica FOCUS SERIES Manual de usuario

Oblica
Oblica skantherm Manual de usuario

Oblica
Oblica Tennessee Manual de usuario

Oblica
Oblica Ortal 75 RS/LS Manual de usuario

Oblica
Oblica FOCUS SERIES Manual de usuario

Oblica
Oblica STUV 16 Manual de usuario