nvent 20836-715 Manual de usuario

VME Subrack System 7 U
User Manual
Product Numbers:
20836-715
20836-718
Revision: R1.1, November 14, 2008
Doc-No: 63972-148

Impressum:
Schroff GmbH
D-75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright © 2006
All rights and technical modifications reserved.
Rev. Date updated Change
R1.0 August 22, 2006 Initial Release
R1.1 November 14, 2008 Part no. FCM added

VME Subrack System 7 U
20836-715/-718
www.schroff.biz I R1.1, November 14, 2008
Table of Contents
1 Safety................................................................................................................. 1
1.1 Intended Application............................................................................................ 1
1.2 Safety Instructions............................................................................................... 2
1.3 Safety Symbols used in this document................................................................ 2
1.4 General Safety Precautions................................................................................. 2
1.5 References and Architecture Specifications........................................................ 3
2 Product Definition............................................................................................. 4
2.1 Mechanical Overview........................................................................................... 5
2.2 Subrack................................................................................................................ 6
2.3 VME Backplane................................................................................................... 6
2.4 Power Supply....................................................................................................... 7
2.4.1 Grounding.............................................................................................. 7
2.5 Thermals............................................................................................................ 10
2.6 Fan Control Module (FCM)................................................................................ 11
2.7 Chassis Monitoring Module (CMM) -optional- ................................................... 12
2.8 Display Module.................................................................................................. 13
3 Installation....................................................................................................... 14
3.1 Unpacking.......................................................................................................... 14
3.1.1 Ensuring Proper Airflow....................................................................... 14
3.2 Rack-Mounting................................................................................................... 15
3.3 Assembly of additional Backplanes................................................................... 16
3.4 Basic Functional Check..................................................................................... 17
4 Service............................................................................................................. 18
4.1 Technical support and Return for Service Assistance....................................... 18
4.2 Declaration of Conformity.................................................................................. 18
4.3 Scope of delivery............................................................................................... 19
4.4 Accessories ....................................................................................................... 19
4.5 Spare Parts........................................................................................................ 19
5 Technical Data ................................................................................................ 20
6 Mechanical Dimensions................................................................................. 21

VME Subrack System 7 U
20836-715/-718
www.schroff.biz II R1.1, November 14, 2008

VME Subrack System 7 U Safety
20836-715/-718
www.schroff.biz 1 R1.1, November 14, 2008
1 Safety
1.1 Intended Application
The VME system subrack, described in this manual, is intended as a platform
for a microcomputer system based on the VME bus system (VITA 1-1994).
The VME system subracks are designed for protection class IP 20 and can be
used only in the resp. environments.
For higher protection requirements, a.e. IP 54/55 you must install the system
subrack in a protective case.
VMEsystemsubracksare notend-products,sothereis novalidapprovalfor this
unit. In order to enable stand-alone functionality, additional elements are
required. An operational system is achieved only by way of appropriate VME
boards.
The completion and final testing of the units have been carried out, or at least
supervised, by qualified technicians. These instructions are directed exclusively
to these qualified technicians i.e.engineers, trained and qualified electricians
etc.
Make sure that:
• the assembled unit complies with the safety regulations currently applicable
in the country it is going to be used.
• the overall unit complies with all other regulations and specifications at the
place and country of use, e.g. interference limits, approval by the telecom-
munications authorities.

VME Subrack System 7 U Safety
20836-715/-718
www.schroff.biz 2 R1.1, November 14, 2008
1.2 Safety Instructions
The intended audience of this User’s Manual is system integrators and
hardware/software engineers.
1.3 Safety Symbols used in this document
1.4 General Safety Precautions
• Service personnel must know the necessary electrical safety, wiring and
connection practices for installing this equipment in a telecommunication
environment.
• Install this equipment only in compliance with local and national electrical
codes.
Hazardous voltage!
This is the electrical hazard symbol. It indicates that there are dangerous
voltages inside the Shelf.
Caution!
This is the user caution symbol. It indicates a condition where damage of the
equipment or injury of the service personnel could occur. To reduce the risk of
damage or injury, follow all steps or procedures as instructed.
Danger of electrostatic discharge!
TheShelfcontainsstaticsensitivedevices.Topreventstaticdamageyoumust
wear an ESD wrist strap.
Warning!
Voltages over 60 VDC can be present in this equipment. This equipment is
intended to be accessed, to be installed and maintained by qualified and
trained service personnel only.
This equipment is designed in accordance with protection class 1!
It must therefore be operated only with protective GND/earth connection!

VME Subrack System 7 U Safety
20836-715/-718
www.schroff.biz 3 R1.1, November 14, 2008
1.5 References and Architecture Specifications
• User Manual VME Backplanes
Order no.: 73972-103
• Short Form User Manual VME J1/J2 Monolithic Backplanes
Order no.: 73972-128
• User Manual Fan Control Module (FCM)
Order no.: 73972-083
For more information see the catalogue „Electronic Packaging“ and at
www.schroff.biz

VME Subrack System 7 U Product Definition
20836-715/-718
www.schroff.biz 4 R1.1, November 14, 2008
2 Product Definition
The Schroff VME subrack system consists of:
• A shielded 7 U / 19“ subrack with front assembly area for
6 U front boards according to VME Standard (VITA 1-1994)
• A VME (VITA 1-1994) Backplane
• An open frame power supply with wide range input
• Speed controlled fans for cooling the boards
• Fan Control Module (FCM) for fan monitoring/controlling
• Display module
• Mains/line switch
The power supply is assembled on the bottom-hinged rear panel.
3 Axial fans, the Fan Control Module (FCM) and the Display Module are located
on a 1 U extractable Fan Tray.
System differences:
The subracks 20836-715/-718 are identical in their construction. The only
difference is the depth (355 mm/475 mm).
Variations
The Schroff assembly service can customize your subrack system with:
• Different Backplane configurations
• Drive mounting cassettes
• Special power supplies
• A Chassis Monitoring Module (CMM)
More information in the catalogue or at www.schroff.biz

VME Subrack System 7 U Product Definition
20836-715/-718
www.schroff.biz 5 R1.1, November 14, 2008
2.1 Mechanical Overview
Figure 1: Mechanical Overview
10006823
1 Front card cage with guide rails 6 Fan Control Module (FCM)
2 Fan Tray 7 VME Backplane
3 Display module 8 Axial fans
4 Power supply 9 AC terminal with line filter and
Mains/line switch
5 Front panel 6 U / 36 HP
FAN
-12V
+12V
+5V TEMP
FAN
-12V
+12V
+5V TEMP
1
3
9
2
6
5
4
7
4
8

VME Subrack System 7 U Product Definition
20836-715/-718
www.schroff.biz 6 R1.1, November 14, 2008
2.2 Subrack
The 7 U / 19“ system based on the Schroff europacPro System with EMC
shielding. The front card cage provides space for the installation of 12 VME
Boards (6 U, 4 HP, 160 mm deep).
The lower guide rails are fitted with ESD clips.
2.3 VME Backplane
The 6 U Backplane (J1/J2 Monolithic) is compliant to:
• VITA 1-1994
• VITA 38 Systemmanagement for VME
The subrack systems 20836-715/-718 have a 12-Slot Backplane as standard.
You can customize your system with different Backplanes.
For more information see the Backplane’s User Manual, Order No.: 73972-103/
-128, in the catalogue and at www.schroff.biz
The front card cage is upgradeable to 21 slots.
1 Slot = 4 HP = 20,32 mm
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Chasis de nvent