Nucleonix PCM 738A Manual de usuario

I N S T R U C T I O N
M A N U A L
PALM CONTAMINATION MONITOR (ALPHA)
TYPE : PCM 738A
NUCLEONIX SYSTEMS PRIVATELIMITED
Plot No: 162 A & B, Phase II, I.D.A. Cherlapally, Hyderabad - 500 051.
Phone: 040-29706483 / 84 / 85, Mobile No: 7331104481 / 82
E-mail: [email protected] Web : www.nucleonix.com
FILE NAME : NSPL/DOC / MAN / PCM 738A/ 02
VER_20150615

Contents
Page No.
3-4
5-6
7-7
8-9
10-13
14-18
S.No.
CHAPTER I
CHAPTER II
CHAPTER III
CHAPTER IV
CHAPTER V
CHAPTER VI
CHAPTER VII
CHAPTER VIII
Description
Introduction
Front panel and Side panel controls /
indications / diagrams
Specifications
Block diagram & Description
Operating Instructions
Circuit Diagrams
Maintenance and Warranty clause
Contact Us for Availing Services
19-19
20-23

CHAPTER- I
INTRODUCTION
Palm Contamination Monitor PCM 738A manufactured by NUCLEONIX SYSTEMS primarily
serves as a personnel monitoring system for checking the Alpha contamination of Palm of
radiation workers / technicians working in Nuclear Power Plants, reactors,
Radiochemical plants and other similar installations. This is wall mounted design.
Start of counting is initiated by an IR source detector arrangement on detection of palm. It can
also be used as a frisker for checking clothing etc after disconnecting IR sensor connector
Guidance to the user during monitoring is in the form of textual messages during monitoring & at
the end of monitoring.
FEATURES :
*Micro-controller based design.
*Efficiency > 25% for Am-241.
*Uses Zns scintillator coupled to 2Pi PMT of suitable dia.
*Provided with a rugged protective grill.
*20X4 LCD display for showing up configuration screens.
*Visual and audio alarms in the event of alarm condition.
*User interface is through a detachable keypad.
*Monitor design ensures continuous maintenance free operation in harsh atmospheric
conditions in Radiochemical plants.
Page 1 of 22

Fig. : Arrangement of Palm Contamination Monitor
Page 2 of 22

CHAPTER - II
FRONT PANEL & SIDE PANEL CONTROLS & INDICATORS
2.1 FRONT PANEL
2.1.1 LCD DISPLAY
This is a 20 X 4 LCD dotmatrix display which shows preset counts, elapsed time and other
status information during acquisition and it also shows various parameters during configuration
2.1.2 STATUS MESSAGES
All status messages are shown 20X4 LCD display during monitoring configuration
The below LEDs are lit when corresponding status is set.10x10mm RED LED is
provided for indication of contamination status after acquisistion.
2.1.3 BUZZER
Audio output is generated by this buzzer in the event alarms are exceeded.
2.2 SIDE PANEL
2.2.1 MAINS ON SWITCH
A toggle switch provided on side panel of display unit & is used to switch DC supply ON/
OFF to the instrument.
2.2.2 DETACHABLE KEYPAD
The detachable keypad provided connects to the unit. This keypad facilitates user to
select suitable program option and configure the instrument
2.2.3 KEYS
A 2x2 matrix detachable keypad has been provided for configuring the instrument.
Keypad details :
a)Fn : Fn key facilitates the user to select the menu options for configuration
like preset time, preset counts, etc.
b)/: These keys facilitates user to edit the selected menu options Keypad
commands have been explained in detail in chapter IV
c)/: start /stop button facilitates the user to aquire in clothing mode by
bypassing the optical sensor.
Page 3 of 22

2.2.4 ADAPTOR JACK PIN
This connector is used to provide charging voltage to the instrument.
2.2.5 USB COMM. PIN
This is used for USB communication through PC
Page 4 of 22

CHAPTER - III
SPECIFICATIONS
Detector : Plastic Scintillator of dimensions 140x220mm covered with
Aluminized mylar film and coupled to suitable PMT serves
as the Alpha detector. It is also provided with a rugged SS
grill for protection to the detection assembly.
Palm Detection : By an IR sensor
Efficiency : Overall efficiency is better than 25% for Am - 241
Display : 20 X 4 dot matrix LCD display for configuration & display
of counts respectively.
Aquisition Modes : Palm / Clothing Modes
Preset time : 1 - 99 secs.
Measuring Range : 0 - 9999 counts / 0-9999 CPS / 0-99999 CPM
Preset counts range : 1 - 9999 counts
User Interface : A 2 X 2 matrix detachable keypad has been provided for
configuring the instrument.
LED
Indication : Contamination.
Audio : Warning audio signals for contaminated and incomplete
operation.
Data storage & transfer : Data storage facility for last 1000 readings is provided.
Each reading is stored along with time stamp. This data
can be transferred through the USB port to PC using data
communication software.
Power Supply : 7.4V Li-ion batteries pack along with AC Charger
Page 5 of 22

CHAPTER - IV
BLOCK DIAGRAM & DESCRIPTION
Palm Contamination Monitor Type PCM738A is designed for operation as a wall mounted
palm monitor and as a hand-held frisker once removed from the wall mount holder.
This is Li-ion battery operated device which is normally connected to AC mains for charging
through charger for frisking in hand-held mode, disconnect banana plug connected to the unit for
battery mode operation.
Palm monitor comprises of the following sub-assemblies
a) Main detector display unit
b) AC charger for 7.4V Li-ion battery
c) Wall mounting arrangement for palm monitor
The block diagram of the palm monitor is illustrated below
AT89V
51RD2
2X2 Keypad
Buzzer
Alarm
LED
20 X 4
LCD display
High Voltage
2 pi
PMT
-ve Tail to TTL
connector
BCD
Counter
ADC
>
<
Optical
Sensor
<
>
>
UART to USB
>
SS
PC
>
USB
>
>
>
+12V
Zns (As)
Scint Detector
>
RTC ><
<
E
2
ROM ><
HV
ref
7.4 Li-ion
AC charger
SS
7.4 Li-ion
Batteries LDO >
+5V
>
Switching
Regulator >
+12V
Page 6 of 22

As the block diagram indicates, Li-ion batteries / AC charger provides the DC voltage to the
electronic unit.
The regulated voltageof +12V are generated by switching regulator and regulated voltages of
+5V is generated by LDO MAX883.
Positive high voltage used for powered by +12V supplies. The high voltage for the PMT is set
at+750 to 800V DC. The Alpha detector ZnS(As) when exposed to alpha particles light
scintillations are provided.
This signal is detected and a -ve tail pulse is produced by the PMT. This signal is amplified by
the hybrid -ve Tail to TTL circuit. The TTL pulse thus produced is fed to display board for
counting and further analysis.
The display board essentially compreses of 20X4 LCD, micro-controller and other
peripherals like BCD counter, RTC, E
2
PROM, UART to USB connector, keypad etc.
The counts recieved from the Tail to TTL connector are fed to the 6 digit BCD conter. The
counts are readout by the micro-controller periodically for counts / count-rate calculations
and display on 20X4 LCD display also reads / sets micro-controller RTC device and displays
on LCD current time and date. The instrument settings area configured through 2X2 front
panel keypad and stored in the E
2
PROM.
Acquisition for palm is initiated on optical sensor transition and goes on uninterrupted until
there is transition in optical sensor status.
At the end of acquisition, result is diplayed on LCD and depending on alarm status, audio
alarms are generated for contamination event.
Acquisition data is stored in the E
2
PROM and it can be transferred to PC through USB port.
Page 7 of 22

CHAPTER - V
OPERATING INSTRUCTIONS
Instructions on operation of intrument
Palm Monitor Type PCM 738A manufactured by Nucleonix is a multi-function contamination
monitoring device. in wall mounted configuration, it works as a Alpha Palm Monitor. When
the palm monitor is detached from its wall mount frame, it can be used as a frisker.
4.1 Use of the instrument as Palm Monitor:
* Mount the instrument in its wall mount frame
* Connect the banana plug to the palm monitor
* Now instrument is ready for use as Palm Monitor
After power ON, the instrument updates background counts as shown below.
E TIME : XXXX BG
COUNTS: XXXXXX
Once acquisition is completed below screen appears
READY....
4.1.1 Configuration before use:
Now press Fn key, password screen appears. Now enter 9090 using &keys.
Use key to increment digit and key to scroll left.
4.1.2 Settings of RTC
Now press Fn key till below screen appears
RTC
XX : XX XX / XX
Use key to increment digit and key to scroll left & set the desired time / date.
Page 8 of 22
Tabla de contenidos