15-1103
Please contact Norwolf Tool Works, Inc. for guidance if or when you are in doubt as to the
operation of this product with your application.
Read all instructions, cautions, warnings and notes carefully. Follow all safety precautions to
avoid personal injury or property damage during use. Norwolf cannot be held responsible for any
damage caused by improper use, lack of maintenance, or incorrect application.
The X-Driver is compatible with three styles of cartridges. The A-Drive, a fixed hex cartridge, the
V-Drive, a square drive cartridge and the M-Drive, which houses any of the following three links:
ratchet cassette, spanner and split link. The connection of the X-Driver to the A, M or V Drive
cartridge is a simple snap-in latch connection.
INSTRUCTIONS
The X-Driver™ operates in union with an air or electric hydraulic pump. The maximum working
pressure of the X-Driver™ is 10,000 PSI. Pump and hose must have the same pressure rating.
WARNING: When pressurized, the X-Driver™ links exert a great reaction force. Follow
instructions for proper tool placement. Keep reaction area free of interference.
WARNIING: Wear personal protective gear, including eye protection, when operating any
hydraulic equipment.
SYSTEM CONNECTION
The X-Driver™ connects with the pump via a double line 10,000 PSI hydraulic hose. Ensure the
connectors (couplers) are fully engaged, with no gap between the male and female fittings.
Threaded connections must be securely tightened and leak free.
WARNING: Never handle pressurized hoses. Escaping oil under pressure can penetrate the skin
causing serious injury. If this occurs seek immediate medical attention.
SETTING TORQUE
NOTE: The pump is to be controlled by the TOOL OPERATOR only.
With the system fully connected, locate desired torque on the conversion chart provided with your
tool. Set the pump to the corresponding pressure. (At this point, the tool is not on the application.)
Turn on the pump, press down on the remote control button and hold. Take reading on the gauge.
To increase pressure, loosen the locking ring on the pressure regulator valve and turn the
thumbscrew clockwise, to decrease pressure turn counter-clockwise. Once the desired pressure
is stabilized, retighten the locking ring.
NOTE: When decreasing pressure, it is necessary to turn pressure setting below what is desired
and gradually increase pressure to the desired level.
Prior to tool operation, again, press down on the remote control button and confirm the correct
pressure has been set on the pump.
NOTE: For “loosening”, set pump at 9500 PSI.
Norwolf Tool Works Asia
T: +65 9795 0752
W: www.norwolftools.sg