4
Version 1.0 October1997
N-750 Configuration Guide
N-750 DIAL UPN-750 DIAL UP
N-750 DIAL UPN-750 DIAL UP
N-750 DIAL UP
INSTINST
INSTINST
INSTALLAALLA
ALLAALLA
ALLATIONTION
TIONTION
TION
With On-BoardWith On-Board
With On-BoardWith On-Board
With On-Board
CommunicatorCommunicator
CommunicatorCommunicator
Communicator
Computer and Software
PC-AC-750
Stand alone PC for N-750 software includes:
CPU, keyboard, mouse, SVGA monitor, parallel printer,
and printer cable.
AND/OR
N-750-SK
Upload/download programming software for the N-750.
Only one copy is required per dealer. The N-750-SK can
support an unlimited number of accounts.
N-750
1 N-750 Security/Access Control Panel
1 N-750-COMM-CBL RJ31X Cable for Digital
Communicator
1 BAT-N-750 12 V, 7 A Battery Backup
1 M-9600 Hi-SpeedCommunications
ExternalModem
1 CBL-2 M-9600 Serial Interface Cable
ACAS Software/Printer Connection
1-8 N-750-PI CommunicationsInterface
1 CBL-N-750-PI Direct Connect Cable–10'
1 N-750-ACAS End-userProgramming Software
1-8 P-1000 Parallel Event/Report Printer
1-8 CBL-1 Parallel Printer Cable
Touchpads/ADMs
1-24*N-750-PAIT Programming & Access Touchpad
1-23*N-750-ADM Access Door Module
*Not to exceed a combined total of 24 PAITs & ADMs
See page 10 for supported reader and card types
Zone Expanders
1-3 N-750 SSE Smart Sensor Serial Zone
Expander
1-40 N-750-SS-10 Smart Sensor 10 Pack
with Resistor
1-40 N-750-EOL-UL-SS 10 pack EOL UL Resistor 1.43 k
for Smart Sensor Expander
1-6 N-750-ZONE Hardwire Zone Expander
1-40 N-750-EOL-UL 10 pack EOL UL Resistor 4.7 k
for hardwire Zone Expander
Not to exceed a combined total of 384 zones
Consult product guide for additional devices
Optional Accessories
N-750-APS 12 VDC Auxiliary Power Supply for
N-750
N-750-APS-24 24 VDC Auxiliary Power Supply for
N-750
N-750-BELL Bell Supervision for N-750
N-750-
BELL-SUP
Bell Suppressor for N-750-BELL
N-750-DPLM Dual Phone Line Module for UL
Communications
N-750-ENC Accessory Enclosure for the N-750
N-750-GSM Ground Start Module for N-750
N-750-KOHP Knock Out Hole Plug for N-750
(UL 6 Pack)
N-750-TC UL Tamper Proof Box for X-750
Transformer
(See pages 13-15 for complete descriptions)
The N-750-PAIT
N-750-PAIT
N-750-ADM
N-750-ADM
N-750-PAIT
You must have at least one
N-750-PAIT per system.
is a
programmable touchpad that
can be used to arm/disarm the
system, or perform a number
of programming functions.
Up to 24 s per
N-750
1 SPDT Relay
2 Dry Contacts
+5VDC or +12VDC Output
Used in conjunction with
s, not to exceed
a total combination of 24
s and
s.
N-750-PAIT
Reader
Exit Switch
Monitor Contact
/Door Zone
Door Strike
/Maglock
PWR
26, 32 and 34 bit
Wiegand Reader
N-750-SSE
Programmable
Touchpad
CBL-1
P-1000
CBL-2
M-9600
PC-AC-750 PC running
N-750-SK Upload/Download
Software for the N-750
N-750-PAIT
The N-750-SSE N-750-SSE
N-750-SS
N-750-SSE SSE
N-750-SS
N-750-SS
N-750-EOL-US-SS
N-750-ZONE
is a Serial Zone Expander
for the N-750. The supports 2
serial lines with a total of 64 points per line
and 128 points per unit. The serial lines may
be run up to 5000' with an Smart
Sensor dropped no more than 200' from the
device to which it is connected.
128 Zones per , 3 N-750 s
per N-750 for a total of 384 zones
Used in conjunction with the
Smart Sensor
Serial Line can go up to 5000' total
distance
Supervised through , for UL
applications use the
10 pack
Can be used in conjunction with
, not to exceed a combina-
tion of 384 hardwired and serial zones
N-750-SS
1.43k EOL Resistor
N-750-EOL-UL-SS
Fire Sprinkler
Glass Break Sensor
A
B
(See p. 10 for available readers)
N-750-SSE
S-4 Suppressor