Nomadic NC-X2 Manual

NC-X2Install Manual
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Version 24013048V | 24V | 12V

NC-X2Instalation Manual Ver. 240130 2 Nomadic Cooling Co
TABLE OF CONTENTS
INTRODUCTION ..........................2
ITEMIZED PARTS LIST .....................3
IMPORTANT SAFETY INSTRUCTIONS......5
NC-X2SPECIFICATIONS ...................6
INSTALLATION INSTRUCTIONS............7
ELECTRICAL WIRING DIAGRAMS .........12
CONTROL PANEL WIRING PHOTOS ......15
TROUBLESHOOT COMMON ISSUES......17
WARRANTY INFORMATION ..............18
RETURNS, CANCELLATIONS, and
MISSING PARTS.........................19
INTRODUCTION
The NC-X2Air Conditioner (“AC unit”) is de-
signed and intended for instalation on the
roof of a recreational vehicle during or after
the vehicle is manufactured.
The NC-X2can be installed by one person with
brief help from one additional person. Reading
this instalation manual in its entirety first will
ensure the proper instalation and function of
the NC-X2.
Nomadic Cooling reserves the right to modify
appearance and specifications without notice.
Always bench test AC unit
before installing.
Check to ensure all required
parts are included (see page 3).
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Keep a record of the following information:
Model
Serial No.
Date Purchased
Installed By
NC-X2Rooftop AC Unit |
48V
24V
12V

Nomadic Cooling Co 3 NC-X2Instalation Manual Ver. 240130
ITEMIZED PARTS LIST

NC-X2Instalation Manual Ver. 240130 4 Nomadic Cooling Co
AC Base Plate
AC Unit / Shroud
Foam Gasket
Vehicle Roof
Crossbars
Optional X2 Trim
Ring (DIY Kit)

Nomadic Cooling Co 5 NC-X2Instalation Manual Ver. 240130
This manual contains safety guidelines and
instructions that can aid in reducing or elim-
inating the risk of accidents and injuries.
A. Recognizing Safety Information
The safety alert symbol is utilized to notify
potential physical injury hazards. To avoid
possible injury or death, follow all safety
messages that come after this symbol.
B. Understanding Signal Words
Signal words identify safety and property
damage messages and indicate the degree
of hazard seriousness.
WARNING is used for hazardous situ-
ations that could result injury (includ-
ing death, severe, moderate or minor
injury if not avoided.
NOTICE is used for situations that
could result in AC unit or vehicle
damage or unnecessary complications
in the instalation process.
HELPFUL TIP is used for useful
information or best practices.
C. Supplemental Directives
To avoid potential injury and even death,
read and follow all of the safety information
and instructions.
Read and comprehend these instructions
before installing, using, servicing, or maintain-
ing this AC unit. Poor instalation, operation,
servicing, or maintenance of this AC unit can
result in severe injury. Follow all instructions.
The instalation must comply with all appli-
cable local and national codes, including the
atest edition of the following standards:
USA
• ANSI/NFPA70, National Electrical
Code (NEC)
• ANSI/NFPA1192, Recreational
Vehicle Code
CANADA
• CSA C22 1. Parts I & II,
Canadian Electrical Code
• CSA Z240 RV Series,
Recreational Vehicles
D. General Safety Messages
WARNING - Failure to follow the subsequent
warnings could lead to death or serious injury.
• A qualified service technician MUST
install or service this product.
• Do NOT modify this product in any
way. Modifications can be extremely
dangerous and void any warranties.
• Do NOT add any devices or accessories
to the AC unit unless specifically
authorized in writing by Nomadic
Cooling Co.
IMPORTANT SAFETY INSTRUCTIONS

NC-X2Instalation Manual Ver. 240130 6 Nomadic Cooling Co
NC-X2SPECIFICATIONS
OFF-GRID AIR CONDITIONING SYSTEMS FOR VANS, RVS & RIGS
Engineered
to fit 14"x14"
industry-standard
rooftop opening.
Powerful cooling,
and 40% smaller
than comparable
units on the market!
Shroud available
in Arctic White
or Obsidian Black.
User Installation and Operation Guide
available at NomadicCooling.com
X2Spec Sheet | Ver. 231218
Remote control
included
Flush-mounted, powder coated
Obsidian Black interior faceplate.
Modern, crisp
LCD panel
22.5"
28"
Our quietest, lowest profile AC unit yet!
48V, 24V and 12V systems available
6.9"
14 "4" 4"
8.6"3.125"
14 "10 .75"
13.5"
Allow 1/8" to 1/4" placement variance
Current ECO Mode 8A 17A 27A
Current MAX Mode 15A 35A 55A
Rated Power 1,070W 900W 720W
Fuse Size 30A 50A 70A
Rated Cooling Capacity (BTU) 12,150 10,280 8,188
Power Cord Specification 10 AWG 8 AWG 4 AWG
Refrigerant R134a @ 450g ± 30g
Refrigerant Oil POE68
Speed Range 1,000 to 3,000 RPM
Weight 44 lbs
Interior Facepate Dimension 16¼" x 16¼" (flush mount)
Noise (Decibels) ≤ 60 dBa
Operation Modes Auto/ECO/MAX/Fan
Min-Max Temp Settings 54°F to 89°F
Warranty
One (1) Year + Extension Option
48V 24V 12V
MODEL
Temp Settings
pg
NC-X2Rooftop AC Unit
48V/24V/12V AW/OBS
PRODUCT:
MODEL:

Nomadic Cooling Co 7 NC-X2Instalation Manual Ver. 240130
INSTALLATION STEPS
1. The NC-X2 is designed to fit an industry
standard 14"x14" opening. If you need to
cut a rooftop opening, mark the interi-
or ceiling using the cardboard tempate
provided in the host box.
Never cover AC top fan. Do not cut
into structural beams.
When determining AC unit location,
be sure to allow for the 22.5" x 28"
shroud when positioned on the roof.
Make sure there are no electrical or
other encumbrances in the way.
2. Make sure the panned opening is
centered from all four sides. This gives
the best chance for easy instalation.
Center the opening between the ribs of the
interior ceiling.
Using the 14"x14" tempate provided, mark
the four corners with a permanent marker.
3. Drill each corner of your markings
through the interior roof using a 1/8” bit.
On the exterior rooftop, use painter’s
tape and a permanent marker to draw
your 14"x14" cutlines from hole to
hole. Make multiple passes with the
permanent marker.
If you make a mistake repace the
tape and try again. Measure repeat-
edly to make sure your lines create a
perfect 14"x14" square.
4. Cut on your lines on the rooftop using a
jig saw, nibbler or cutting wheel.
Use a sander or file to smooth out the
rough edges after cutting.
14”
14”
14”14”
Interior Ceiling
Ceiling Ribs
14"x14" opening
centered between ribs
Vehicle Front
Interior Ceiling
Front of Vehicl
e

NC-X2Instalation Manual Ver. 240130 8 Nomadic Cooling Co
5. Paint around the edges of the cut roof
opening to prevent rust. You can use any
color rust-preventative paint.
6. Remove tape and clean surface.
7. Remove waterproof gasket from box.
Make sure area/paint is clean, dry and
clear of all debris.
Use alcohol wipes or PrepSol to
remove oil or wax from vehicle roof.
If pacing gasket over a high or uneven
roof surface, remove small amounts of the
14"x14" gasket to match roof contours.
Use bade to cut away gasket
if needed.
Remove gasket adhesive only after
making any necessary cuts. Pace the
gasket sticky side down.
8. Apply polyurethane adhesive seaant (in-
cluded in DIY kit) around 14"x14" gasket.
9. Gently pace AC unit on roof over gasket.
Inner gasket dimension is 14"x14", outer
dimension is 16.25"x16.25". Measure side-
to-side until centered on all four sides.
Be careful not to puncture, rip
or tear the gasket with AC unit’s
mounting bolts.
Do not put adhesive on top of gasket.
Do not damage electrical components
when pacing AC unit.
10. Adhere optional leveling strip behind the
foam gasket.
Exterior Roof
Exterior Roof
URETHANE ADHESIVE
CUTAWAYS FOR ROOF RIDGES
Leveling strip
14” x 14” gasket
Adhesive side

Nomadic Cooling Co 9 NC-X2Instalation Manual Ver. 240130
11. From inside the vehicle add the crossbars
to attach AC unit to the roof. Locate the
mounting bolts, washers and nuts.
Do not use electric drill on crossbars.
12. If possible with your particuar build, we
recommend using a trim ring to provide ad-
ditional support around the rooftop open-
ing. The DIY kit includes a Nomadic Cooling
X2trim ring. Professional upfitters typically
create their own custom trim rings.
13. Add the nut, washer and lock washer to
each of the four bolts that screw into the AC
unit base pate through the crossbar.
Hand-tighten all four bolts to the AC unit.
Do not over tighten! Once all four bolts are
hand-tight, torque the lock nuts to 3.7 lb to
secure the crossbars to the AC unit, and the
AC unit to the roof.
With optional Trim Ring:
If NOT using a trim ring, you may use
the optional pastic spacer for the two
rear bolts, between the crossbars and
the AC unit base.
Without Trim Ring showing optional spacer:
During the instalation process, if the
locking nut is installed too tightly, it
may cause deformation of the AC unit
base pate. The spacer can pay a limit-
ing role, with any excess locking force
acting on the spacer instead of the AC
unit base pate.
A sticker found on the bag
of bolts may say to tighten
to 5.0 lbs. of torque, please
disregard and use the rec-
ommended 3.7 lbs.
AC unit will help to create pressure.
When securing AC unit to the vehicle,
increased compression of the gasket
will level the unit against the roof. No
light should be visible.
Do not over-tighten mounting bolts.
Bolts will rotate if over-torqued,
and may break from AC base pate.
Over-tightening will void warranty.
FrontRear
Trim Ring
Crossbar
Gasket
Spacer
Back of AC unit
Hand tighten all 4
bolts to crossbars,
then torque the
nuts to 3.7lbs (~5nm).
Crossbar
Washer
Lock Washer
Nut (fat side up)
Bolt
Pastic Spacer
(optional if not
using Trim Ring)
Vehicle Roof (cutout)
Gasket
Trim Ring (Optional)
AC Base Pate
FrontRear

NC-X2Instalation Manual Ver. 240130 10 Nomadic Cooling Co
Our gaskets are used for vibration
absorption. It is very high density and
can’t be compressed more than 10%.
Use gasket tension to control AC unit’s
distance from roof surface.
AC unit should be resting on foam gasket
and not on the vehicle’s roof.
Over compression of the unit to the
roof may cause the internal fan to rub
against the fan housing.
Be sure the fan bades rotate freely
prior to starting the unit.
12. Install and connect LCD control panel
before connecting to power to avoid
blowing internal fuse.
An appropriately-sized fuse must be
paced between your power source
and the AC unit:
48V = 30A fuse
24V = 50A fuse
12V = 70A fuse
13. Connect DC power wires to unit. “Quick
Connection to DC Wiring Harness” included.
12V systems use an Anderson connector,
24V and 48V systems use a simiar Ander-
son style connector.
Make sure wiring is appropriately
sized and is no smaller than 4AWG.
14. Attach LCD control panel and AC
wiring harnesses.
15. Attach thermostat wires to control panel
wiring harness.
Details of control panel connections are
shown in electrical diagram on page 12.
Condenser is always to the left of the
back wire. Be careful not to break
these wires.
16. Use the foam separator to properly sepa-
rate hot air from cold air as it enters and
exits the AC unit.
AC unit centered
on foam gasket
Foam separator
AIR IN AIR OUT
To AIR-OUT sensor
To Control Panel
Otros manuales para NC-X2
1
Tabla de contenidos
Otros manuales de Acondicionador de aire de Nomadic