824
Each SFD-2 is provided with a "protective conductor terminal"
which shall be terminated to earth ground potential (see
Electrical Installation). This product's design complies with
EN61010-1 installation category II and pollution degree 4.
Hazardous Location Caution:
The SFD-2 sensor is “approved” for use in certain Hazardous
Locations (see specifications). The products shall only be used
in applications covered by these ratings or those considered
non-hazardous. Failure to comply could result in catastrophe
damage to personnel and property. The following must be main-
tained to assure safe operation:
1) Housing integrity - the dimensions of the housing,
cover or process seal shall not be altered.
2) Maintenance - Removal of the sensor cover to conduct
maintenance while power is yet supplied does not meet
hazardous location requirements. If done, it is at the
risk of the customer only.
adiated Energy
OSHA has adopted regulations designed to prevent possible
harmful effects in human being from exposure to electromagnet-
ic fields in the frequency range of 300 KHz to 100 Hz. The
SFD-2 generates energy within this band. OSHA permits human
exposure to power densities up to 10mW/cm2 for 1/10 hour or
greater continuous duration. The SFD-2 produces a power den-
sity less than 1mW/cm2 at the sensor face and therefore poses
no health danger to operators or the general public.
Electromagnetic Compatibly (EMC)
The SFD-2 was tested and found to comply with the standards listed
below. The SFD-2 should not be used in residential or commercial envi-
ronments. Compliance to the EMC standards was demonstrated by
means of a test setup using the following installation methods.
1) SFD-2 sensor was connected to earth ground (protective earth).
2) Shielded cable was used to interconnect the sensor and power sup-
ply/conditioner connections (+, and -). The shield drain was connected to
earth ground (SHLD terminal) at the power supply/conditioner end.
EMC Emissions:
Meets EN 61326-1 Electrical Equipment for Control Use, EMC
EN 55011 Radiated and conducted emissions
(Class A - industrial)
EN 61000-3 Fluctuation/Flicker
Meets FCC Part 15B RF Devices, Unintentional Radiators
CISPR 11 Radiated and conducted emissions
(Class A- industrial)
EMC Immunity:
Meets EN 61326-1 Electrical Equipment for Control Use, EMC
IEC 1000-4-2 Electrostatic discharge (industrial)
IEC 1000-4-3 RF radiated EM fields (industrial)
IEC 1000-4-4 Electrical fast transients (industrial)
IEC 1000-4-5 Electrical surges (industrial)
IEC 1000-4-6 RF conducted EM energy (industrial)
IEC 1000-4-8 Power frequency magnetic fields (industrial)
IEC 1000-4-11 Source voltage deviation
Ryton®- Trademark of Phillips Chemical Co.
Teflon®- Trademark of Dupont Chemical Co.
TRI-CLOVER® - Trademark of Tri-Clover Inc.
WARRANTY
SENSO
Enclosure cast aluminum, polyester coated (beige)
Enclosure protection NEMA 4, IP66
Operational temp. range -40 to +185 degrees F (-40 to +85 degrees C)
Process temp. max +250 degrees F (+121 C) if ambient air
temp. below +150 degrees F (+65 C)
Process seals TFE Teflon®, Ryton®-equivalent
Pressure ratings TFE Teflon®(75 PSI intm.), Ryton®-equiv. (300 PSI)
Process connection 1 1/4" NPT (flush mount with half coupling)
Conduit connection (2) 1/2" NPT
Detection range 0 to 10’ free air, environment and target
dependent
Sensitivity switch selectable HI/LOW
Minimum Velocity: 2.5 ft/sec (7.62mm/sec)
Power requirement provided by power supply/conditioner PCB
Output none, signal delivered to and processed by
power supply/conditioner
Indicators reen LED- power
Yellow LED- loop, intensifies with motion
Emission 24.125 Hz, FCC and IC certified, less than
1mW/cm2(OSHA limit at 10mW/cm2)
Approvals Class II, Div. 1, roups E, F &
(CSAUS/C)
CE Mark
POWE SUPPLY/CONDITIONE (PS/COND)
Installation Category II
Pollution Degree 4
Altitude 6562ft (2000M) max
Enclosure (if applicable) PBT/Polycarbonate
Enclosure protection NEMA 4X, IP66, Suitable for outdoor use
Operational temp. range -40 to +158 degrees F (-40 to +70 degrees C)
Interconnection distance 2500ft max (minimum wire size 22 AW )
Power 100-240VAC(+10%) 50/60 HZ
Power consumption 5 VA max
Output DPDT dry contact, 5A @ 250VAC or 30VDC
External lights (if applicable) solid state LED clusters; Yellow- material sense,
Red- output operate
Sensitivity adjustment single-turn adjustment 0~100% of sensor
range
Time delay hold-off, single-turn adjustment,
.25~15 seconds
hold-on, single-turn adjustment,
.25~15 seconds
Fail-safe switch selectable, (FLOW/NO-FLOW)
Indicators reen LED- power, Yellow LED- sense,
Red LED-output
Approvals ordinary locations, industrial control
equipment (CSAUS/C)
CE Mark
Fuse 250VAC, 315mA, TR-5, FAST
S ECIFICATIONS