Acusensor M Installaon Manual
P/N C-00187 Rev 8-25-17
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operaon: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
• NEVER leave a Door operating without all Safety detection systems operational.
WARNING
Table of Contents
............................................................. 3
Secon 1.1: Warning Labels ...................................................................3
Secon 1.2: General Safety Recommendaons ...................................................3
.............................................................. 4
Secon 2.1: To the Installer ....................................................................4
Secon 2.2: Objecve ........................................................................4
..................................................... 4
.......................................... 5
.......................................... 8
Secon 5.1: Secure Sensor to Header ...........................................................8
Secon 5.2: Install the Angled Spacer (Sold Separately) ............................................8
............................................. 9
Secon 6.1: Wire Swing Door with Monitoring (Opus Control) .......................................9
Secon 6.2: Wire Fold Door with Monitoring (Opus Control) .......................................10
Secon 6.3: Wire Slide Door with Monitoring (U30 Control) ........................................10
...............................................
Secon 7.1: Operaon Mode (Switches 1 and 2) .................................................12
Secon 7.2: Output Logic (Switch 3) ...........................................................12
Secon 7.3: Input Logic (Switch 4) .............................................................13
Secon 7.4: Width Seng (Switches 5 thru 8) ...................................................13

2 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
..............................................
Secon 8.1: Depth Seng (Switches 9 thru 11) ..................................................15
Secon 8.2: Learn Time (Switches 12 and 13) ....................................................17
Secon 8.3: An-Noise (Switch 14) ............................................................18
Secon 8.4: An-Environment (Switches 15 and 16) ..............................................18
Secon 8.5: Sensivity (Switches 17 and 18) ....................................................18
Secon 8.6: IP Mode (Switches 19 and 20) ......................................................19
....................................................
...................................................
.......................................................

3 of 28
www.NabcoEntrances.com AcusensorMInstallaonManual
Rev 8-25-17 P/N C-00187
Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning
Indicates potentially dangerous situations. Danger is used when there is a hazardous situation
where there is a high probability of severe injury or death. It should not be considered for
property damage unless personal injury risk is present.
Indicates a hazardous situation which has some probability of severe injury. It should not be
considered for property damage unless personal injury risk is present.
Indicates a hazardous situation which may result in a minor injury.Caution should not be used
when there is a possibility of serious injury. Caution should not be considered for property
damage accidents unless a personal injury risk is present.
Do not place nger or uninsulated tools inside the electrical controller. Touching wires or
other parts inside the enclosure may cause electrical shock, serious injury or death.
Disconnect power at the fused disconnect during all electrical or mechanical service. When
uncertain whether power supply is disconnected, always verify using a voltmeter.
If the door appears broken or does not seem to work correctly, it should be immediately
removed from service until repairs can be carried out or a qualied service technician is
contacted for corrective action.
DANGER
WARNING
CAUTION
DANGER
WARNING
CAUTION

4 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
The purpose of this manual is to familiarize the installer and purchaser with the proper installaon and operaon of the Acusensor
M. It is essenal that this equipment be properly installed and operaonal before the door is used by the public. It is the installer’s
responsibility to inspect the operaon of the entrance system to be sure it complies with any applicable standards. In the United
States, ANSI Standard 156.10 (Full Energy) covers these types of doors. Other local standards or codes may apply. Use them in
addion to the ANSI standard.
Instruct the building owners and operator on the essenals of the operaon of the door and this device. The owner should follow
these instrucons to determine whether the door is operang properly and should immediately call for service if there is any
malfuncon. All installaon changes and adjustments must be made by qualied, NABCO trained technicians.
If aer troubleshoong a problem, a sasfactory soluon cannot be achieved, please call Nabco Entrances at 1-877-622-2694
between 8 am – 4:30 pm Central me for addional assistance.
Acusensor M is mounted on the Header Cover for all Slide Door Units, Swing Door Units, and Fold Door Units. The Acusensor M is
used to detect changes of mulple near-infrared rays that beam from the Sensor down to various points on the oor. The Acusensor
M can detect a moving pedestrian or object, or a staonary pedestrian or object. Upon Presence Detecon, the Acusensor M
outputs a detecon signal to Control. The Control automacally sends a signal to the Motor/Operator, the Motor/Operator opens
the automac door.
The Acusensor M was developed based on the concept of safety, comfort, reliability and mulpurpose.
All wiring must conform to standard wiring practices and be in accordance with national and
local electrical codes.
Note: It is recommended for the Installer to use an Electrical Conduit to house all incoming 120 VAC wires.
Table 1
Specification Description
Sensing System Acve reecve near infrared system (Moon/Presence)
Life Expectancy (5) years. LED illuminates a:
►White light during Learning that blinks twice every (5) seconds
►Green light during Normal Operation that blinks twice every (5) seconds
• Flashing LEDs do not indicate that the Sensor is failing.
• Flashing LEDs indicate that the Sensor has been in use for a period of me, and replacement
is recommended. This is done to ensure connued safe operaon of the door.
Applicable door Sliding door/Swing door/Folding door
Detecon Area ►Without angled spacer
• Width 114”(2.9m) x Depth 71”(1.8m) (at mounng height 87”(2.2m))
►With angled spacer (sold separately)
• Width 114”(2.9m) x Depth 78”(2.0m) (at mounng height 87”(2.2m))
The width and depth of a Detecon Area may vary. For details, please refer to Table 3-1. This is
typically the result of:
►A variance in mounting height.
►Normal manufacturing and component tolerances.
►
►Use of spacers for mounting.
Output Contacts Rang Non-polarized, No voltage, Semi-conductor relay output 30 VAC/50VDC, 0.1A (Resistance Load)
N.C. or N.C.
When Set to N.O. ►No Detection “Open”
►Detection “Closed”
►Power Failure “Open”
►Sensor Malfunction “Closed”
WARNINGWARNING

5 of 28
www.NabcoEntrances.com AcusensorMInstallaonManual
Rev 8-25-17 P/N C-00187
Specification Description
Mounng Height 78 inches to 118 inches (2.0m to 3.0m)
Weight Approximately 10 ounces (285g)
Color Black Cover or Silver Cover
Full Color LED ►Displays operating status
Angled Spacer The Angled Spacer is an opon that is sold separately. To do so, please call Customer Service at
1-888-679-3319.
►For Slide doors only
►For increased depth range.
Adjustable Detecon Area
►Depth
►Width
ECO Mode Closes door earlier for a pedestrians moving away from door.
Table 2 Electrical Wiring
Item Description
Input Voltage 12-24 Volts AC or DC
Power Consumpon 3VA or less @ 24VAC
80mA or less @ 24VDC
150mA or less @ 12VDC
Output ►
►Max. 100mA @ 30VAC/50VDC
Make sure total power consumption of all Sensors does not exceed the capability of the door control or power supply.
Exceeding the rated output may result in malfunction or breakdown.
The Sensor is used to detect changes of mulple near-infrared rays that beam from the Sensor down to various points on the oor.
These various points reect the near-infrared rays to form an grid in the shape of a square. To more acurately monitor a Presence
Detecon Area, the grid is broken into invisible rows (Depth), and columns (Width).
DN 1567
Mounng
Height
Row 1
Row 2
Row 3
Row 4
Row 5
Row 6
AB
CDEF

6 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
Table 3 Detection Area Size
Without Angled Spacer (Area Adjuster set at 0 degrees)
Mounting Height 78” (2.0m) 87” (2.2m) 98” (2.5m) 118” (3.0m)
Depth
A 4” (100mm) 4” (100mm) 5” (120mm) 6” (150mm)
B 15” (390mm) 17” (430mm) 19” (480mm) 23” (580mm)
C 26” (650mm) 28” (720mm) 32” (820mm) 39” (980mm)
D 38” (960mm) 41” (1,050mm) 47” (1,200mm) 57” (1,440mm)
E 51” (1,300mm) 56” (1,430mm) 64” (1,620mm) 77” (1,950mm)
F 63” (1,600mm) 72” (1,820mm) 82” (2,070mm) 98” (2,490mm)
Width
G 48” (1,220mm) 53” (1,350mm) 60” (1,530mm) 72” (1,840mm)
H 83” (2,100mm) 91” (2,320mm) 104” (2,630mm) 124” (3,160mm)
I 104” (2,640mm) 114” (2,900mm) 130” (3,300mm) 156” (3,960mm)
With Angled Spacer (Area Adjuster set at 0 degrees)
Mounting Height 78” (2.0m) 87” (2.2m) 98” (2.5m) 118” (3.0m)
Depth
A 4” (100mm) 4” (100mm) 5” (120mm) 6” (150mm)
B 15” (390mm) 17” (430mm) 19” (490mm) 23” (590mm)
C 26” (670mm) 29” (740mm) 33” (840mm) 40” (1.010mm)
D 38” (1000mm) 43” (1,100mm) 49” (1,250mm) 59” (1,500mm)
E 54” (1,370mm) 59” (1,510mm) 68” (1,720mm) 81” (2,060mm)
F 71” (1,790mm) 78” (1,970mm) 88” (2,240mm) 106” (2,680mm)
Width
G 48” (1,230mm) 53” (1,350mm) 61” (1,540mm) 79” (1,850mm)
H 83” (2,110mm) 91” (2,320mm) 104” (2,640mm) 125” (3,170mm)
I 104” (2,650mm) 114” (2,920mm) 131” (3,320mm) 157” (3,980mm)
Illustrated examples shown below, are meant to display some (not all) causes for malfuncon to occur within the Presence
Detecon Area.
Table 4 Common Causes for Malfunctions
The bed of a trolley:
XIs too low to the oor
XSurface of cart or trolley is not reecve enough to be detected. (Reecve
tape or sckers can help)
Refl ec ve S cker
Trolley BedDN 1568

7 of 28
www.NabcoEntrances.com AcusensorMInstallaonManual
Rev 8-25-17 P/N C-00187
Sensor is exposed to:
XSteam
XExhaust fume
XInsects
XHeavy rain
XHeavy snow
DN 1572
Pool of water located within Presence Detecon Area
DN 1571
An object placed within the Presence Detecon Area that may be moving within
the detecon area (like due to wind).
DN 1573
Mulple Sensors installed close to each other, or facing each other Within 197” (5m)
DN 1569
Presence Detecon Area is ooded with:
XStrong direct Sunlight
XSunlight reecng from oor (such as marble, or aluminum oors)
XStrong direct arcial light
XArcial light reecng from oor (such as marble, or aluminum oors)
XLighng xtures placed too close to the Sensor
DN 1570

8 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
Shut OFF the installation site, branch Circuit Breaker. Failure to do so may result in serious
personal or fatal injury. When uncertain whether power supply is disconnected, always verify
using a voltmeter.
All high voltage electrical connections must be made by licensed electricians according to
National and Local electrical codes/regulations.
Permanent wiring shall be employed as required by local codes.
Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. 120 VAC
Power wires must be routed (separate from other wiring) located near the top of inside Header.
1. Turn OFF power.
2. Remove Cover from Sensor.
3. Remove (2) #10 x 1/2 inch Phillips Panhead screws from the cradles.
DN 1574
#10 x 1/2”
Phillips Head
Screw
Sensor
Cover
Figure 1 XXXX
4. Line up the predrilled screw holes located on the Mounng Plate with predrilled screw holes on the Header Cover.
5. Secure the Sensor to the Header Cover with (2) #10 x 1/2 inch Phillips Panhead screws.
Predrilled
Screw Holes
Predrilled Screw Holes
Sensor
DN 1575
#10 x 1/2”
Panhead Screw
Figure 2 Recessed Track
Note: The Angled Spacer is an opon that is sold separately. To do so, please call Customer Service at 1-888-679-3319.
1. Turn OFF power.
2. Remove Cover from Sensor.
3. Seat the Sensor inside the Angled Spacer.
a. The at side of Angled Spacer must bu up against the Header Cover.
4. Align the predrilled screw holes located on the Mounng Plate with the predrilled screw holes located on the Angled Spacer.
5. Secure the Sensor to the Header Cover with (2) #10 x 5/8 inch Phillips Panhead screws (supplied with the Angled Sensor Kit.
a. Do not use (2) #10 x 1/2” Phillips Panhead screws that were supplied with the Acusensor M kit.
WARNING
WARNING
CAUTION
CAUTION

9 of 28
www.NabcoEntrances.com AcusensorMInstallaonManual
Rev 8-25-17 P/N C-00187
DN 1580
Figure 3 Install the Angled Sensor
DN 1578
7
6
54
321
10
98
11 12 13 14
ACUSENSOR M TO OPUS IN SWING DOOR WITH MONITORING
ACUSENSOR M
ACUSENSOR M
APROACH SIDE (ACTIVATION)
SWING SIDE (SAFETY)
RED
BLACK
BROWN
GREEN
V-00741
V-00741
ACUSENSOR M HARNESS
A-01292
ACUSENSOR M HARNESS
A-01292
YELLOW
GREY
RED
BLACK
BROWN
GREEN
YELLOW
GREY
P.N. A-00805
ON/OFF/HOLD-OPEN SWITCH
BLUE
WHITE
BLACK
RED
Off
Hold Open
On
Off

10 of 28
Acusensor M Installaon Manual www.NabcoEntrances.com
P/N C-00187 Rev 8-25-17
DN 1577
7
6
54
321
ACUSENSOR M
ACUSENSOR M
FOLD SIDE ACTIVATION
APROACH SIDE ACTIVATION
FOLD SIDE SAFETY
RED
BLACK
BROWN
GREEN
V-00741
V-00741
ACUSENSOR M
V-00741
ACUSENSOR M HARNESS
A-01292
1
2
3
1
2
4
1
2
6
To Terminal # on Opus Control
ACUSENSOR M HARNESS
A-01292
ACUSENSOR M HARNESS
A-01292
YELLOW
GREY
7
RED
BLACK
BROWN
GREEN
YELLOW
GREY
7
RED
BLACK
BROWN
GREEN
YELLOW
GREY
7
ACUSENSOR M TO OPUS IN FOLDING DOOR
WITH MONITORING
DN 1579
1
2
3
4
BROWN, GREY
RED, GREEN, BLUE
BLACK, WHITE
YELLOW
ACUSENSOR M
SWING SIDE (SAFETY)
V-00741
ACUSENSOR M HARNESS (WITH CONNECTOR)
P.N. A-01292
RED
BLACK (or Black with Red Stripe)
BROWN
YELLOW
ACUSENSOR M TO U-SERIES IN SLIDE DOOR WITH MONITORING
FROM U-SERIES CONTROL
BLACK
WHITE
BROWN
YELLOW
RED
GREY
GREEN
BLUE
Tabla de contenidos