Section 1
General Description
The ID20 is a long range microwave motion sensor for
activating automatic industrial doors. Features include a
speed selectable switch that makes the unit capable of
detecting pedestrians and/or vehicles. Detection mode
is selectable between approach-only or depart-only
motion and the weatherproof housing makes it ideal for
installation in exterior applications.
Microwave technology allows the ID20 to detect larger
objects, such as forklift trucks, up to 60 feet away.
Maximum pattern size is approximately 18 ft. wide at 60
ft. from the unit and is adjustable via a range
potentiometer on the printed circuit board. The ID20 is
not affected by air motion, change in temperature,
humidity, color or background variations.
Section 2
Installation
Mounting (Fig. 1)
1. Remove 1/4-20 hinge bolt holding the mounting
bracket to the sensor housing and detach the
mounting bracket.
2. Using the mounting bracket as a template, mark and
drill mounting holes in the desired location.
3. After attaching the mounting bracket in the desired
location, re-attach the sensor housing to the
mounting bracket with the 1/4-20 hinge bolt
removed in step 1.
Wiring (Fig. 2)
Wiring the sensor must be done with the sensor cover off.
Remove the four hex head screws. Two are located on
the front plate and two are located on the back plate.
The cover is then removed by lifting up slightly and sliding
forward (Fig. 1).
1. With Power off, pull 4 conductor cable through the
wire fitting and make all wiring connections to the
terminal block located on the printed circuit board
(Fig. 2).
NOTICE: Operating voltage is 12V to 24V AC or
DC and should be applied through the
transformer supplied with the unit. Allow the
device 10 seconds to warm up once power is
applied.
WARNING: Do Not ground one side of the
secondary of the supply transformer. Circuit
ground of the unit is electrically connected to
the housing. Grounding one side of the
transformer may create a direct short that will
permanently damage the unit.
NOTICE: 4 conductor cable, 18 to 22 gauge
conductor size, 3/16” to 5/16” cable O.D. is
recommended.
For more information, call us toll-free at (317) 842-2545.
Set Up & Alignment (Fig. 2)
1. Set up the sensor parameters via the 4 dip switches
and 2 position slide switch located on the printed
circuit board (Fig. 2).
NOTICE: Dip switch #2 provides speed
detection adjustment. ON = detection of
vehicles & pedestrians traveling 3 mph+. OFF =
detection of objects & pedestrians traveling 1
mph+. For installations where pedestrian
detection is not desired, set dip switch #2 to
ON.
NOTICE: Dip switches 3 & 4 are not used.
2. Align the ID20 by adjusting the range potentiometer
and aiming angle to achieve the desired pattern
placement and size. To adjust the sensor’s aiming
angle, loosen the 1/4-20 hinge bolt, adjust and
retighten.
NOTICE: A time delay adjustment potentiometer
is available to adjust the amount of time the
relay stays energized after detection is lost.
3. An LED located on the main printed circuit board will
illuminate when the relay has changed state in
response to motion providing a visual indication that
the unit is working.
4. Once set up and alignment is completed, replace the
cover and ensure that all bolts and screws are
tightened.
!
!
!
!
!
!
8701 Castle Park Drive Indianapolis, Indiana 46256
Telephone: (317) 842-2545 www.mssedco.com custsvc@mssedco.com

ID20
Industrial Door Microwave Motion Sensor INSTALLATION INSTRUCTIONS
Page 2
(/MANU) ID20v0913
Section 3
System Inspection and Instructions
*****EXTREMELY IMPORTANT*****
After final set-up, test unit(s) completely to ensure that
proper coverage has been achieved (width, depth and
location of the pattern must be tested).
After the installation and operational check of the
system:
1. Place the proper warning labels on the door.
2. Instruct the owner of the door system operation and
how to test it. This should be checked on a daily
basis.
3. Instruct the owner on what to do if the door or any of
its components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.
TYPICAL PATTERN DIAGRAM
Mounting Height: 12 Ft.
Tip Angle: 16°
Section 4
Technical Data
Model................................ ID20
Frequency..........................10.525 GHz
Detection Pattern............. Adjustable Range (see typical
pattern diagram)
Detection Angle................ Adjustable, Horizontal &
Vertical
Detection Mode................Unidirectional (approach only
or depart only)
Response Time.................0.150 seconds
Hold Time..........................0 to 5 seconds
Power Requirements........12 to 24V AC or DC
Current Consumption.......0.075 Amp @ 24V DC
Relay Contacts..................Form C, rated at 3 Amps
Mounting...........................Heavy-duty bracket, predrilled &
slotted
Temperature..................... -35°F to 165°F
(-35°C to 74°C)
Weight............................... 3.5 lbs. (1.6 kg)
Size....................................7" x 4" x 4"
17.8cm x 10.2cm x 10.2cm
Color/Enclosure................Aluminum, black powder coat
finish
Section 5
Warranty
MS SEDCO guarantees this product to be free from manufacturing
defects for one year from date of installation. Unless MS SEDCO is
notified of the date of installation, the warranty will be in effect for
one year from the date of shipment from our factory. If, during the
first year, this device fails to operate and has not been tampered
with our abused, the unit can be returned prepaid to factory and it
will be repaired free of charge. After one year, the unit will be
repaired for a nominal service charge. This limited warranty is in
lieu of all other warranties expressed or implied, including any
implied warranty of merchantability, and no representative or
person is authorized to assume for MS SEDCO any other liability
in connection with the sale of our products. All warranties are
limited to the duration of this written warranty. In no event shall
MS SEDCO be liable for any special, incidental, consequential or
other damages arising from any claimed breach of warranty as
to its products or services.
Range
Pattern - Horizontal and Vertical
ID20
16°
4'
7'
10'
12.5'
15.5'
18.5'
Width
0' 10' 20' 30' 40' 50' 60'
8701 Castle Park Drive Indianapolis, Indiana 46256
Telephone: (317) 842-2545 www.mssedco.com custsvc@mssedco.com

ID20
Industrial Door Microwave Motion Sensor INSTALLATION INSTRUCTIONS
Page 3
(/MANU) ID20v0913
FIGURE 1
Mounting Bracket
Base
Cover
Wire Fitting
Hex Head
Cover
Screw (2)
Hex Head Cover
Screw (2)
1/4-20 Hinge Bolt
ID20 Housing
8701 Castle Park Drive Indianapolis, Indiana 46256
Telephone: (317) 842-2545 www.mssedco.com custsvc@mssedco.com

ID20
Industrial Door Microwave Motion Sensor INSTALLATION INSTRUCTIONS
Page 4
(/MANU) ID20v0913
8701 Castle Park Drive Indianapolis, Indiana 46256
Telephone: (317) 842-2545 www.mssedco.com custsvc@mssedco.com
FIGURE 2
1
2
3
4
5
6
Input Power
12 to 24 Volts AC/DC
1 2 3 4
ON
1 2 3
RELAY
Direction
App Dpt
Option Dip Switch
#1 Switch Function:
OFF = cycle relay upon power up.
ON = no cycle relay upon power up.
#2 Switch Function:
Speed Detection Adjustment
ON (default) = 3 mph+
OFF = 1 mph+
#3, & #4 = no function
Relay Connections
4 = Normally Open (N.O.)
5 = Common
6 = Normally Closed (N.C.)
NOTE: Relay is with power applied and
unit setup for Failsafe operation.
Time Delay Adjustment
0 to 5 seconds
Clockwise to increase, counterclockwise
to decrease.
NOTES:
1) The LED Indicator is illuminated whenever the Relay is activated.
2) The Range Adjustment allows the Pattern/Distance to be varied for each individual installation.
3) The Time Delay Adjustment sets the relay hold time after the unit has stopped detecting motion.
Relay Failsafe Selection Jumper
Jumper 1&2 = Failsafe operation
Jumper 2&3 = Fail Secure operation
Direction Switch
(Approach or Depart)
Range Adjustment
Variable Control -
Approx. 0 to 60 Feet
LED Indicator
Tabla de contenidos
Otros manuales de Accesorios de MS Sedco

MS Sedco
MS Sedco DH94D Manual de usuario

MS Sedco
MS Sedco INTERSECTOR SDLC Manual de usuario

MS Sedco
MS Sedco SmartWalk XP Manual de usuario

MS Sedco
MS Sedco DH97 Manual de usuario

MS Sedco
MS Sedco INTERSECTOR Manual de usuario

MS Sedco
MS Sedco microStar Manual de usuario

MS Sedco
MS Sedco DH400 Manual de usuario

MS Sedco
MS Sedco DH100-CT Manual de usuario

MS Sedco
MS Sedco MicroStar blue Manual de usuario