MPB PIRS Manual de instrucciones

MPB S.r.l.
Via Giacomo Peroni 400/402
00131 Rome - Italy
www.gruppompb.uk.com
Quick start Manual PIRS
Quick Start Manual
PIRS
Quick start Manual Version: 1.1
Updated to the Software Version: 1.0.0
Updated to Firmware Version: 1.01

QUICK START MANUAL
PIRS
- 2 -
SAFETY NOTES
Read before using the product
MPB works to provide the best safety conditions available and complies with the latest safety
standards.
The instrumentation described in this manual was produced, tested and left the factory in
conditions that fully comply with European standards.
To ensure the correct use of the product, these general instructions must be read and
applied before and for any use of the instrumentation.
The PIRS is made for industrial environments and should be used by authorized staff only.
MPB disclaims any responsibility for a use of the device different from explained in the
manual.
In order to keep the 24 months warranty, please do not remove the seals of the instrument.

QUICK START MANUAL
PIRS
- 3 -
Declaration of conformity
(according to EMC 89/336/EEC directive and low voltage 73/23/EEC)
This is to certify that the product: PIRS
complies with the following European standards:
Safety: EN 61010-1 (undated reference, applies to all editions)
EMC emissions: EN 61326-1 (undated reference, applies to all editions)
EMC immunity: EN 61326-1 (undated reference, applies to all editions)
This product complies also with the 2014/35/CE Low voltage directive
requirements and with 2014/30/EU Electromagnetic compatibility
and with R0HS 2011/65/EU
MPB S.r.l.

QUICK START MANUAL
PIRS
- 4 -
Index
1. General information .............................................................................................................................. - 5 -
1.1. Introduction................................................................................................................................... - 5 -
1.2. System description ........................................................................................................................ - 5 -
1.3. System composition and optional accessories.............................................................................. - 5 -
1.4. Technical specifications ................................................................................................................. - 6 -
2. Operating principles .............................................................................................................................. - 7 -
2.1. Block diagram ................................................................................................................................ - 7 -
2.2. Working principles of PIRS............................................................................................................. - 7 -
3. Software ................................................................................................................................................ - 8 -
3.1. Installation..................................................................................................................................... - 8 -
3.2. Connecting the instrument.......................................................................................................... - 10 -
3.3. New list creation.......................................................................................................................... - 11 -
3.4. Edit list ......................................................................................................................................... - 11 -
3.5. Delete list..................................................................................................................................... - 11 -
3.6. Delete frequency ......................................................................................................................... - 11 -
3.7. Add frequency ............................................................................................................................. - 12 -
3.8. Delete all frequency from list ...................................................................................................... - 12 -
3.9. Wizard table ................................................................................................................................ - 12 -
4. Calibration ........................................................................................................................................... - 13 -
4.1. General ........................................................................................................................................ - 13 -
4.2. Quiet zone pre-saved .................................................................................................................. - 13 -
4.3. Quiet zone with sample probe .................................................................................................... - 13 -
5. Measures ............................................................................................................................................. - 14 -
5.1. setup ............................................................................................................................................ - 15 -
- Turn on the PIRS .............................................................................................................................. - 15 -

QUICK START MANUAL
PIRS
- 5 -
1.General information
1.1. Introduction
The PIRS (Portable Immunity Radiation System) is an innovative system to generate
amplified CW signals with calibration feedback.
1.2. System description
The PIRS can be used for Pre compliance Radiated Immunity Test (in accordance to the
IEC 61 000-4-3) and to generate the electric fields with intensity among 1 V/m and 30 V/m
inside shielding rooms, TEM and GTEM Cells, anechoic and semi anechoic chambers.
Thanks to its batteries power supply and its 8 hours autonomy (in generation and
continuous power amplification), it can be used with extreme ease in any environment,
mostly in “Situ” to perform Radiated Immunity Test on high dimensions devices hardly to
transport inside anechoic chambers or test labs.
Figure 1
1.3. System composition and optional accessories
Standard composition:
- PIRS
- Protective bag

QUICK START MANUAL
PIRS
- 6 -
Options:
- Tripod support NMR-01
- Tower up to 4m NMR-03
- Log periodic antenna LP-02
- Biconical antenna BC-01
- Biconical log periodic antenna BL-01
- PIRS converter
- RF Power meter
- Broadband meter
1.4. Technical specifications
Frequency Range
10 kHz … 3 GHz
Resolution
1 Hz
Connectorization
N-Type
Max output power (Typ)
37 dBm @1 MHz
Min output power (Typ)
3 dBm @ 3 GHz
Display
graphic 240x128
I/O interface
USB, fiber optic
Reference Standards
IEC 61000-4-3 (pre-compliance)
Operating Temperature
-10°…40°C
Certificate of Calibration
Standard; LAT
Dimensions
30 x 15 x 8 cm
Weight
1.7 kg
Power
8 batteries 18650 rechargeable and replaceable by the
operator
Custom list
From 128 to 500 points each
Auto calibration
- Set point
- Feedback tolerance
With sample probe or with mathematical model
Configurable for each list via software
Minimum user defined 2.5% (Typ 5%)
Feedback
- With sample probe
- With power meter
Configurable from one second minimum
Freq. freely configurable via PC
Freq. available on the antenna certificate
Persistence generation
Configurable from one second minimum
Compatibles tools
8053B, OR03, WBM, 6630F0A+6630
Technical specifications may change without notice

QUICK START MANUAL
PIRS
- 7 -
2. Operating principles
2.1. Block diagram
The block diagram below represents the PIRS:
Figure 2
2.2. Working principles of PIRS
The PIRS is an instrument design to speed up the generation of known electromagnetic
fields. Carrying out the proper calibration, using a sample probe (see cap 4Calibration) it is
possible to create, at selected frequencies, a table of power that the PIRS must generate
in order to have a target filed, chose by the operator. The field generated will be a function
of the distance of the object to be radiated, the type of antenna and the environment.
By the PIRS the operator creates a quite field area in which to immerse the instrument he
wants to test.

QUICK START MANUAL
PIRS
- 8 -
3. Software
3.1. Installation
Launch the setup file (setup.exe) and eventually click YES/Execute in the pop up window.
Please note that the PIRS SW can require to be “executed as administrator”.
Follow the steps as in the following figures.
Figure 3

QUICK START MANUAL
PIRS
- 9 -
Figure 4
Figure 5

QUICK START MANUAL
PIRS
- 10 -
Figure 6
3.2. Connecting the instrument
1) Start the PIRS Software, connect the USB cable to the computer and to the
instrument: at the first connection, wait for the driver installation, at the end of which
a notification of the operating system will appear
Figure 7
Tabla de contenidos
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación