MOGlabs MWM Manual de usuario

MWM wavemeter
Revision3.19 mogwave 1.4.15 Firmware0.6.9

Limitation of Liability
MOGLaboratoriesPtyLtd(MOGLabs)doesnotassumeanyliabilityaris-
ing out of the use of the information contained within this manual. This
documentmaycontainorreferenceinformationandproductsprotectedby
copyrights or patents and does not convey any license under the patent
rightsofMOGLabs, nor the rightsofothers. MOGLabswillnotbeliable
for any defect in hardware or software or loss or inadequacy of data of
anykind,orforanydirect,indirect,incidental,orconsequentialdamages
inconnections withorarising outoftheperformanceor useofany ofits
products. Theforegoinglimitationofliabilityshallbeequallyapplicable
toanyserviceprovidedbyMOGLabs.
Copyright
Copyright c
MOG Laboratories Pty Ltd (MOGLabs) 2014 – 2020. No
part of this publication may be reproduced, stored in a retrieval system,
ortransmitted,inanyformorbyanymeans,electronic,mechanical,pho-
tocopyingorotherwise,withoutthepriorwrittenpermissionofMOGLabs.
Contact
Forfurtherinformation,pleasecontact:
MOGLaboratoriesP/L
49UniversitySt
CarltonVIC3053
AUSTRALIA
+61399390677
MOGLabsUSALLC
41914thSt
HuntingdonPA16652
USA
+18142514363
www.moglabs.com

Preface
The MOGLabs MWM wavemeter provides a compact, high resolution and
costeffective instrumentformeasuring thewavelengthand spectrumofa
laser. The instrument can be operated standalone, and easily controlled
fromacomputerwithasophisticatedhostapplicationorusingsimpletext
commands,viaUSB andethernet. Thelowpricemakesisaffordableeven
ifyouhavejustonelasertomeasure.
WehopethatyoufindtheMWMuseful,andpleaseletusknowifyouhave
anysuggestionsforimprovementoftheMWM orthisdocument,sothatwe
canmakelifeinthelabbetterforall.
MOGLabs,Melbourne,Australia
www.moglabs.com
i

ii

Contents
Preface i
1 Introduction 1
1.1 Basicsetup............................ 1
1.2 Softwareinstallation . . . . . . . . . . . . . . . . . . . . . . . 3
2 Standalone operation 5
2.1 On-devicemeasurements . . . . . . . . . . . . . . . . . . . . 5
2.2 Frontpaneldisplayandbuttons . . . . . . . . . . . . . . . . 5
2.3 Measuring............................. 6
2.4 Devicemenus........................... 7
3 Web interface 11
3.1 Homepage ............................ 12
3.2 Liveview.............................. 13
3.3 Live+................................ 14
3.4 Devicesetup............................ 14
3.5 Software.............................. 16
3.6 Updatefirmware......................... 16
4 MOGWAVE 17
4.1 Devicediscovery......................... 17
4.2 Maindisplay........................... 18
4.3 Menu................................ 20
4.4 Acquisition............................. 25
4.5 Options............................... 25
4.6 Wavelength............................ 26
4.7 Functions ............................. 27
4.8 Statusbar............................. 29
iii

iv Contents
5 Signal out and PID 31
5.1 MOGLabsDLC lasercontroller . . . . . . . . . . . . . . . . . 32
5.2 PIDparameters.......................... 32
5.3 Integratorwindup......................... 33
5.4 Examples.............................. 34
6 Calibration 37
6.1 Existingwavelengthrange . . . . . . . . . . . . . . . . . . . 37
6.2 CalibratingwithMOGLabsFZWwavemeter . . . . . . . . . 40
6.3 CalibratingwithHighFinessewavemeter . . . . . . . . . . . 40
6.4 Newwavelengthrange. . . . . . . . . . . . . . . . . . . . . . 41
6.5 Newfibre............................. 44
A Specifications 47
B Communications 51
B.1 TCP/IP............................... 51
B.2 USB................................ 54
C Programming 59
C.1 python example.......................... 59
D Command language 63
D.1 Wavelengthmeasurement . . . . . . . . . . . . . . . . . . . . 63
D.2PIDcontrol............................ 64
D.3Generalfunctions......................... 65
D.4Displayfunctions......................... 66
D.5 Auxilliarymeasurements. . . . . . . . . . . . . . . . . . . . . 66
D.6Imaging............................... 68
D.7 Configurationsettings . . . . . . . . . . . . . . . . . . . . . . 70
D.8EEPROMaccess......................... 73
Emogwave configuration 75
E.1 Command-lineoptions . . . . . . . . . . . . . . . . . . . . . . 75
E.2 Configurationfile......................... 77
Fmogwave server 79
F.1 Enablingtheserver. . . . . . . . . . . . . . . . . . . . . . . . 79
F.2 Communicationwiththeserver . . . . . . . . . . . . . . . . . 79
F.3 mogwave commands........................ 80

vi Contents

1. Introduction
TheMOGLabsMWMopticalinstrumentisahighresolutiondiffractiongrat-
ingspectrometerinLittrowconfiguration. Opticalinterferencecreatesan
imageofasinglemodefibrecoreatawavelength-dependentpositionona
semiconductorimagingsensor. Theimageisdigitisedathighspatialreso-
lutionandwithhighdynamicrangeandspeed. Thewavelengthspectrumis
determinedfromthedigitisedimageandafittingproceduredeterminesthe
peakwavelength. Itprovidespicometre(0.001nm)accuracyandpicowatt
sensitivity, with up to 1250 readings per second. The relative accuracy,
forexampleinmeasuringthedifferencebetweentwolaserwavelengths,is
around10MHz(0.01pm).
The device can be operated standalone (without a host computer, see
fig.1.1)orviaawebbrowser(fig.1.2)orusingthemogwave GUIapplication
(chapter 4). Integration with data acquisition systems is straightforward
usingUSBorethernet(TCP/IP)communicationsandsimpletext-basedcom-
mands.
Figure 1.1: Wavemeteron-devicedisplay,showingserialnumber,firmwarever-
sion,wavelengthrange,temperature,pressure,exposuredurationandIPaddress.
1.1 Basic setup
1. Connect a 5V 500mA power supply via the USB interface. Some
computer USB ports will provide sufficient power but in general a
dedicatedpowersupplyorUSB hubisrecommended.
2. Second and third generation (Rev 2 and later) instruments have
1

2Chapter 1. Introduction
Figure 1.2: Webinterfacehomepage.
poweron/offviatheOKpushbutton. Topoweronoroff,holdtheOK
buttondownfor2to3seconds.
3. If possible, use a network connection for improved response times
andfasterdata acquisition. Connecttoan ethernet switchandthe
MWM willattempttodetermineanIP addressviaDHCP.Ifthatfails,
it will default to an internal IP which will be shown on the instru-
ment display. See chapter B for more information on configuring
communicationsparameters.
4. TheMWMmustbecoupledtothelightsourceviaasingle-modeopti-
calfibre. Multimodefibreisnot suitable. Theinstrumentsensitivity
isveryhighandsothefibremodediameterneednotbewellmatched;
forexample,a480nmfibrecanbeusedtomeasure780nmlightand
vice versa, though best accuracy and stability are achieved if the
fibre is matched to the wavelength. Fibres with FC/PC (preferred)
or FC/APC connectors can be used, and standard or polarisation-
maintainingfibre.
Note: Yourdevicehasbeenconfiguredandcalibratedusingafibre
witheitherFC/PC orFC/APC connector, usuallywithFC/PCatthe
wavemeter. Pleaserefertothetestdataprovidedwithyourdevice.
If you use a different connector type, you will need to reconfigure
andrecalibrate. Pleaseseesection4.8.
Caution: Thefibretipisanintegralpartoftheinstrument. Unclean
Tabla de contenidos
Otros manuales de Equipo de laboratorio de MOGlabs
Manuales populares de Equipo de laboratorio de otras marcas

Agilent Technologies
Agilent Technologies 5800 ICP-OES Manual de usuario

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Manual de usuario

NI
NI PXI-5422 Manual

Collomix
Collomix Aqix Manual de usuario

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Manual de usuario

Ocean Insight
Ocean Insight FLAME-NIR+ Manual de usuario














