Milesight GS301 Manual de usuario

Bathroom Odor Detector
Sensor
Featuring LoRaWAN®
GS301
User Guide

2
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the
instructions of this operating guide.
The device must not be disassembled or remodeled in any way.
In order to protect the security of the device, please change device password when first
configuration. Default password is 123456.
Do not place the device outdoors where the temperature is below/above operating range.
Do not place the device close to objects with naked flames, heat source (oven or sunlight),
cold source, liquid and extreme temperature changes.
The device is not intended to be used as a reference sensor, and Milesight will not should
responsibility for any damage which may result from inaccurate readings.
The device must never be subjected to shocks or impacts.
Keep the device away from the water to prevent damage to the detector and electric shock.
Keep the device out of children’s reach.
Declaration of Conformity
GS301 is in conformity with the essential requirements and other relevant provisions of the CE,
FCC, and RoHS.
Copyright © 2011-2023 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual
shall copy or reproduce the whole or part of this user guide by any means without written
authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Support portal: support.milesight-iot.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: Building C09, Software Park III,
Xiamen 361024, China
Revision History
Date
Doc Version
Description
Jun.5, 2023
V 1.0
Initial version

3
Contents
1. Product Introduction ......................................................................................................................... 4
1.1 Overview ...................................................................................................................................4
1.2 Features ................................................................................................................................... 4
2. Hardware Introduction ...................................................................................................................... 5
2.1 Packing List ..............................................................................................................................5
2.2 Hardware Overview ................................................................................................................. 5
2.3 LED and Button Patterns .........................................................................................................5
2.4 Dimensions(mm) .....................................................................................................................6
3. Operation Guide .................................................................................................................................6
3.1 Basic Configuration ................................................................................................................. 6
3.2 LoRaWAN Settings .................................................................................................................. 7
3.3 Basic Settings ........................................................................................................................10
3.4 Advanced Settings ................................................................................................................ 10
3.4.1 Calibration Settings .................................................................................................... 10
3.4.2 Threshold Settings ..................................................................................................... 11
3.4.3 Milesight D2D Settings ...............................................................................................11
3.5 Maintenance .......................................................................................................................... 13
3.5.1 Upgrade ....................................................................................................................... 13
3.5.2 Backup .........................................................................................................................13
3.5.3 Reset to Factory Default .............................................................................................14
4. Installation ....................................................................................................................................... 15
5. Detector Maintenance .................................................................................................................... 16
6. Milesight IoT Cloud Management ..................................................................................................16
7. Device Payload ................................................................................................................................ 17
7.1 Basic Information .................................................................................................................. 18
7.2 Sensor Data ........................................................................................................................... 18
7.3 Downlink Commands ............................................................................................................ 19
Appendix .............................................................................................................................................. 21
Ammonia (NH3) Levels and Guidelines ......................................................................................21
Hydrogen Sulfide (H2S) Levels and Guidelines ..........................................................................21

4
1. Product Introduction
1.1 Overview
GS301 is a 4-in-1 LoRaWAN®bathroom odor detector to detect ammonia (NH3) and hydrogen
sulfide (H2S) gas according to electrochemical principle. GS301 is also able to detect
temperature and humidity to fully aware of the environment of bathrooms. When the NH3or H2S
gas concentration reaches the preset threshold, the detector will trigger both LED light alarm and
buzzer to notify people timely to ventilate, which is an important part in smart bathroom
solution.
Apart from local alarms, GS301 can also report the sensor data and alarm messages remotely
using LoRaWAN®technology. Integrating with Milesight LoRaWAN®gateway and Milesight IoT
Cloud solution, users can monitor all the sensor data and control the deice remotely and flexibly.
Moreover, GS301 supports Milesight D2D to enable ultra-low latency control without gateways.
1.2 Features
Built-in high accuracy electrochemical gas detection sensor with more than 3-year-long life
expectancy
Built-in multiple sensors including NH3, H2S, temperature and humidity
Built-in batteries to achieve wireless power supply and decrease in installation cost
Equipped with buzzer and LED indicator to indicate threshold alarms
Damp proof coating inside the device to ensure device working well on various conditions of
bathrooms
Support Milesight D2D protocol to enable ultra-low latency and direct ventilation control
without gateways
Built-in NFC for easy configuration
Compatible with standard LoRaWAN®gateways and network servers
Quick and easy management with Milesight IoT Cloud solution

5
2. Hardware Introduction
2.1 Packing List
1 × Bathroom Odor
Detector
2 × Wall Mounting
Kits
1 × Quick Start
Guide
1 × Warranty Card
If any of the above items is missing or damaged, please contact your sales Representative.
2.2 Hardware Overview
2.3 LED and Button Patterns
Function
Action
LED (Enable)
Power ON/OFF
Press and hold the button for more
than 3 seconds.
Power On: Off →On
Power Off: On →Off
Check On/Off Status
Quick press the power button once.
Device On: Blink Once
Device Off: Off
Reset to Factory Default
Press and hold the reset button for
more than 10 seconds
Quickly Blinks
Threshold Alarm
When any concentration of NH3or
H2S exceeds the threshold
Quickly Blinks

6
2.4 Dimensions(mm)
3. Operation Guide
3.1 Basic Configuration
1. Long press and hold the power button for more than 3 seconds to power on the device. After
powering on or rebooting, wait for about 30 minutes for sensor polarization process. Only when
the polarization completes, the device can collect NH3and H2S data.
2. Download and install “Milesight ToolBox” App from Google Play or Apple App Store.
3. Enable NFC on the smartphone and launch Milesight ToolBox.
4. Attach the smartphone with the NFC area to the device to read device information. Basic
information and settings of the device will be shown on ToolBox App if it’s recognized
successfully. You can read and configure the device by tapping the Read/Write device on the
App. To order to protect the security of the device, please change the password when first
configuration. The default password is 123456.
Note:
1) During polarization process, temperature and humidity data will be collected as usual, NH3

7
and H2S values will be shown 655.34 ppm on ToolBox page.
2) Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
3) If the smartphone fails to read/write configurations via NFC, keep the phone away and back
to try again.
4) GS301 can also be configured by a dedicated NFC reader, which can be purchased from
Milesight IoT.
3.2 LoRaWAN Settings
Go to Device > Settings > LoRaWAN Settings to configure join type, App EUI, App Key and other
information. You can also keep all settings by default.
Parameters
Description
Device EUI
Unique ID of the device which can also be found on the label.
App EUI
Default App EUI is 24E124C0002A0001.
Application Port
The port is used for sending and receiving data, the default port is 85.
Join Type
OTAA and ABP mode are available.
LoRaWAN Version
V1.0.2, V1.0.3 are available.
Work Mode
It’s fixed as Class A.
Application Key
Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823.
Device Address
DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Network Session
Nwkskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.

8
Key
Application
Session Key
Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
RX2 Data Rate
RX2 data rate to receive downlinks or send D2D commands.
RX2 Frequency
RX2 frequency to receive downlinks or send D2D commands. Unit: Hz
Channel Mode
Select Standard-Channel mode or Single-Channel mode. When Single-Channel
mode is enabled, only one channel can be selected to send uplinks. Please
enable Single-Channel mode if you connect device to DS7610.
Channel
Enable or disable the frequency to send uplinks.
If frequency is one of CN470/AU915/US915, enter the index of the channel
that you want to enable and make them separated by commas.
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60
All: Enabling all channels
Null: Indicates that all channels are disabled

9
Spread Factor
If ADR is disabled, the device will send data via this spread factor.
Confirmed Mode
If the device does not receive ACK packet from the network server, it will
resend data once.
Rejoin Mode
Reporting interval ≤ 30 mins: the device will send a specific number of
LinkCheckReq MAC packets to the network server every 30 mins to validate
connectivity; If there is no response, the device will re-join the network.
Reporting interval > 30 mins: the device will send a specific number of
LinkCheckReq MAC packets to the network server every reporting interval to
validate connectivity; If there is no response, the device will re-join the
network.
Set the number of
packets sent
When rejoin mode is enabled, set the number of LinkCheckReq packets sent.
ADR Mode
Allow the network server to adjust datarate of the device. This only works
with Standard Channel Mode.
Tx Power
Transmit power of the device.
Note:
1) Please contact sales for device EUI list if there are many units.
2) Please contact sales if you need random App keys before purchase.
3) Select OTAA mode if you use Milesight IoT cloud to manage devices.
4) Only OTAA mode supports rejoin mode.

10
5) For -868M model, the default frequency is EU868; for -915M model, the default frequency is
AU915.
3.3 Basic Settings
Go to Device > Settings > General Settings of ToolBox App to change the reporting interval, etc.
Parameters
Description
Reporting Interval
Reporting interval of transmitting current sensor values to the network
server. Default: 10 mins, Range: 1-1080 mins
Temperature Unit
Change the temperature unit displayed on the ToolBox.
Note:
1) The temperature unit in the reporting package is fixed as °C.
2) Please modify the threshold settings if the unit is changed.
LED Indicator
Disable or enable LED Indicator for alarming when the value of NH3or
H2S exceeds the threshold.
Buzzer
Disable or enable buzzer for alarming when the value of NH3or H2S
exceeds the threshold. The buzzer will automatically stop if both values
are lower than the threshold. If you want to stop the buzzing, please
disable the buzzer.
Change Password
Change the password for ToolBox App or software to read/write this
device.
Note: When temperature is higher than 35°C, LED indicator and buzzer alarm will stop working
until the temperature goes back to 35°C or below.
3.4 Advanced Settings
3.4.1 Calibration Settings
ToolBox supports numerical calibration for temperature and humidity. Go to Device > Settings >
Tabla de contenidos
Otros manuales de Sensor de seguridad de Milesight

Milesight
Milesight EM500 Series Manual de usuario

Milesight
Milesight EM310-TILT-868M Manual de usuario

Milesight
Milesight VS132 Manual de usuario

Milesight
Milesight EM320-TILT-868M Manual de usuario

Milesight
Milesight WS202-868M Manual de usuario

Milesight
Milesight WS302-868M Manual de usuario

Milesight
Milesight VS121 Manual de usuario

Milesight
Milesight AM100 Series Manual de usuario

Milesight
Milesight EM300 Series Manual de usuario

Milesight
Milesight EM320-TH-868M Manual de usuario