MileSeey S3 Manual de usuario

MileSeey S3 series handheld laser distance meter user guide
1. Overview
MileSeey S3 series product measures up to 100m, integrates tilt
sensor and full color screen, is specially for professional users.
Initial adoption of li-ion battery, which greatly enhances usage life
and can last for several years. In addition, it is more green.
mOS V1.0, is an innovated and patent measuring system, which
has vivid colorful screen, strong interactive interface, and has
professional measuring functions. The various supplement
functions and unique personal setting providing unexpected
measuring experience and fun.
The perfect combination of ergonomic design and fashion provides
amazing functions and experience. The product leads to a new
era of professional measurement.
2. Start-up&Shut-down
1) Inserting/replacing batteries
Remove battery compartment lid by pressing it lightly, insert the provided Li-ion battery
and close the cover.
Remove the batteries before any long period of non-use to avoid the danger of
corrosion.
Your strongly recommended to user li-ion batteries which is produced by original laser
meter producer.
2) Start-up
Press key to start-up, and directly go to the interface of single measuring(see figure).
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

3) Manual Shut-down
Pressing this button for longer switches the instrument off.
4) Auto Shut-down
The instrument switches off automatically after three minutes of inactivity.
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

3. Button functions
1.Area/Volume/ Pythagoras
2.Plus/Go Up
3. Tilt/ triangle
4.Confirmation
5.Go Right
6.Saving/Historical data
7. Power On/Measuring (On/Single/continuous meas)
8.Menu/Power Off
9.Minus/Go Down
10. Reference
11.Go Left
12. Clear/Cancel
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

4. Display screen general view
The graphics screen of the measurement window is split into different areas. Top second
screen is the measurement functional field, which contains the currently selected
measuring program. Just to the left/right appears the program submenu, which shows the
measuring programs that can be selected by pressing the same key the required number
of times. The measurement field contains the individual measurements of the measuring
program with reference to a series of separate distance measurements. Three lines are
provided for last measurement data. A horizontal line separates the measurement field
and the result bar from one another.
1 Status bar with (time, battery status, bubble)
2 Program selection with measurement instructions
3. Status of measurement, (Reference, laser on)
3 Measurement field
4 Result bar
5 Measurement type
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

5. Measuring
In measuring mode, user can press to delete the current measured data and
re-measure.
1) Single Measuring
Following 3 entries lead to single measurement function (see figure)
Press key to start-up, and directly go to the interface of single measuring
It will be back to this mode after completing measurement every time.
User will be back to single measuring mode by press one or more times in
menu setting interface.
Press to activate the laser. Press again to trigger the distance measurement. The
result is displayed immediately.
2) Continuous Measuring
Press and hold down the key until hear "beep" to activate continuous measurement.
This function enable user to measure the minimum or maximum distance from a fixed
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

measuring point. User can press or to stop the function, and The values for
maximum and minimum distances are shown in the display as well as the last measured
value in the summary line.
3) Area Measuring
Press once, the symbol appears in function filed of display.
Press to take the first distance measurement (e.g. Length).
Press again to take the second distance measurement (e.g. width).
The results of length, width, perimeter and area are displayed in the historical data line in
order.
4) Volume Measuring
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

Press twice, the symbol appears in the function field on the display, and the
volume function activated as well.
Press to take the first length measurement (e.g. Length). Next get the width, then
heights, the final result is displayed in the summary line.
Press and to display additional room information such as ceiling/floor, surface
area of the walls, circumference.
5) Single Pythagoras
Press three times to activate the function,symbol appears in the function field
on the display as following to take No. 1, and No. 2 length, the result is displayed on the
summary line. Press to delete any measured length and then press to
re-measure.
6) Double Pythagoras
Press four times to activate the function, the symbol display in function field
as following to take No.1,2 and 3 length,
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

the height is displayed on the summary line. Press to find additoinal information
6. Tilt measurement
1) Tilt measurement
Press button,the symbol appears in the function field, press to take
the inclination and the distance.
The inclination sensor measures tilts between ± 45°.
During the measurement of tilt, the instrument should be held without transverse tilt,
as far as possible within ± 10°. The accuracy is 0.3°.
2) Auto horizontal measurement
Press twice ,the symbol appears in the functional field. Press button to
measure angel and distance, The summary line displays the result as the direct horizontal
distance
3) Auto height measurement
Press third times ,the symbol appears in the functional field. Press button
to take both sloping sides, the vertical height is displayed in the summary line.
4) Triangular measurement
Press four times ,the symbol appears in the functional area. Press button
to take 3 sloping sides respectively, the area is displayed in the summary line. Press
to find out each angel of the Triangular and circumference.
7. Edit Measuring data Function
Note: this function is only enabled in measurement mode and at least a measured data
display in the screen.
1) Select data
Press or to select measuring type in measuring process file (left handside of the
screen) , press to locate the corresponding data, the data frame turning yellow
indicates the data has been selected.
2) Re-measure:
When this data was selected, press to re-measure the distance till the result is
satisfied. Press or return to measurement interface,
3) Adjust measurement result:
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

When this data was selected, press , the cursor appears in the measurement type
field, press or move the cursor to select the digit of data, and press or to
increase or reduce the value, press to save and return to measurment interface, or
press cancel the modification and return the previous data.
4) Addition / subtraction:
When this data was selected, press to appears in the measuremnt type field, press
the next measurement is added to the previous, In the same approach, Press ,
the The next measurement is subtracted from the previous one. press to save
and return to measurment interface, or press cancel the modification and return the
previous data.
8. Data locking:
1)Data locking introduction:
Usually the instrument keeps and deletes the measurement data in sequence of first in
first out. The first in value will be deleted if total measurement data reach the maximum
storage (eg.30 records). This function enable user to save data permanently except user
deletes it manually from memory.
2) Lock data:in mode of measuring, when measuring, select data, press , the dialog
box pop up user to select “save” button, then press “ ” to lock the data, return to
measurement interface.
3) Lock/unlock data:in Historical record function: In history data interface, move cursor to
navigate the data, then to lock it. And press again to unlock the data.
9. Historical record:
1) Historical record view:
Press to call up the function, press or to select the measurment type, sorting
by which, all of the data record displays in sequnce of created time.
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

2) View detail record
Press to read detail informaton of this record, including data type
(locked/unlocked) ,no.of order all data, date, time, measurement function, measurement
types , corresponding result, additional information,
For example, in function of volume measuemnt, additional infomration such as
ceiling/floor area , surface area of the walls , circumference displays.
3) Historical record delete
Batch records delete:
When cursor select one of measurement type,Press , then press to delete all the
historical records belonging to this measurement type.
Single record delete:
Press or to browse the record then Press , and press to delete the record.
Press or to browse the record then repeatedly press to loock and unlock the
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
Tabla de contenidos
Manuales populares de Instrumento analítico de otras marcas

EXTOL PREMIUM
EXTOL PREMIUM 8820043 Instrucciones de instalación y funcionamiento

RIDGID
RIDGID SeeSnake Compact Manual de usuario

Teledyne
Teledyne 3000PA Manual de usuario

YDLIDAR
YDLIDAR TIA Manual de usuario

Olympus
Olympus IPLEX FX Series Manual de usuario

Bosch
Bosch GLM 50 C Professional Manual de usuario