Pressing and hold 『+/20 』,『S 』, and『-/4 』buttons at the same time for more than 3 seconds to cancel the setting.
If none of the buttons were pressed for more than 5 minutes during the setting process, the setting mode is canceled.
2)-2 Fine adjustment of 20mA output
1. Press and hold 『+/20 』buttons for 3 seconds or longer to start setting mode.
2. Decrease the 20mA output value.
Press 『-/4 』button …4mA output value will decrease each time the button is pressed.
Press and hold the button and the value will decrease continuously.
3. Increase the 20mA output value.
Press 『+/20 』button … 4mA output value will increase each time the button is pressed.
Press and hold the button and the value will increase continuously.
4. Press 『S 』button for more than 3 seconds to complete the setting.
Pressing and hold 『+/20 』,『S 』, and『-/4 』buttons at the same time for more than 3 seconds to cancel the setting.
If none of the buttons were pressed for more than 5 minutes during the setting process, the setting mode is canceled.
3) Output Increase Direction Setting
3)-1 Increase output direction to CW shaft rotation
1. Press and hold both 『+/20 』and 『S 』buttons for 3 seconds or longer to start setting mode.
2. Press 『+/20 』button …Increase output direction to CW shaft rotation.
3. Press 『S 』button for more than 3 seconds to complete the setting.
Pressing and hold 『+/20 』,『S 』, and『-/4 』buttons at the same time for more than 3 seconds to cancel the setting.
If none of the buttons were pressed for more than 5 minutes during the setting process, the setting mode is canceled.