Installation and using guide – Page 6/15
Your device is not yet operational, after the installation of the battery you have 30 minutes to carry out
the tests and adjustments specified hereafter. During these 30 minutes the siren is in low power mode (test
mode).
IMPORTANT
•When you purchase the device, the central unit is preset for a rectangular pool, 4X8 meters long and 1,40
meters deep (most common standard pools – French standard NF P 90-307)
•Some 4X8 meters swimming-pools do not correspond precisely to these recommendations. In order to
optimize the device performances to your pool, it is possible to benefit from adjustments possibilities of the
device (advanced tests).
•Nevertheless, before any intervention on the preset adjustments, it is advised to carry out the bases tests.
•In order to obtain an optimal adjustment of your device, we advice you to carry out all these tests, in a
completely calm pool, with the lid in position (You do not have to screw it, except if there is some wind)
•Before any test, make sure your central unit is in « active monitoring » mode (no flashing of the led). If it is
not the case, apply the magnet on the swimmer until you obtain a long beep and the led stops flashing.
•WARNING: If you hear short beeps after the long beep and the led is still flashing, the device automatically
switches to « inactive monitoring » mode, the pool is too agitated to allow a correct analysis. It is advised to
start again the operation once the pool is calm.
•For the following tests, when the siren sets off: apply the magnet on the swimmer until the alarm stops.
4.2.2 Basic tests
• Test 1 : Filtration
•Leave your central unit on for 10 minutes while the filtration is operating.
•If the device automatically switches to « inactive monitoring » mode (10 short beeps sequence + flashing
led), the preset adjustment is not suitable for your pool, please, go directly to the advanced tests (paragraph
4.2.3)
•
• Test 2 : Robot
•Leave your central unit on while the robot is operating in the pool.
•If the device automatically switches to inactive monitoring mode (10 short beeps sequence + flashing led) ,
the preset adjustment is not suitable for your pool, please, go directly to the advanced tests (paragraph
4.2.3)
•WARNING: Some cleaning robots which climb to the water line (Robots which go in and out of the water
and cause an event which might be considered like the fall of a child in the pool) are incompatible with
immersion detection systems.
• Test 3 : Fall
•Simulate the fall of a body in the pool by making a child or a 6-8 litres water jerry can or the dummy from
your retailer from the curb stone. The alarm must set off within 12 seconds maximum after the fall.
• Fall detected within 12 seconds : stop the alarm
• Fall not detected or detected in more than 12 seconds : go to the advanced tests (paragraph 4.2.3)
If you passed the whole basic tests successfully, go directly to paragraph 4.2.4