1
Kit content:
•Air quality monitor with: CO2, PM2.5, TVOC, HCHO, temperature, humidity
•µUSB cable, and power supply adapter
•User manual
Other material needed for the installation:
•On the wall, an electrical outlet with or without a ground connection near where the
mBox Guardian will be installed (<1m).
Positioning of the station:
Be sure to position mBox Guardian:
•On one of the walls of the room.
•At a height between 1 and 2 m corresponding as much as possible to the height of the
respiratory tract of people occupying the premises (children, adults, seated people
mostly ...).
•Out of draughty areas (air intake or exhaust, door, window).
•Away from heat sources (radiator, direct sunlight).
•Away from specific and localized sources of pollution (kitchen, garbage can, changing
area, perfume diffuser...)
•More than 1m from the corners of the room.

2
Product:
Thanks for choosing our Air Quality Sensor mBox Guardian MMG-174. There are high
precision sensors inside it and mainly used for indoor to detect the PM2.5, Carbon Dioxide
(CO2), Formaldehyde (HCHO), TVOC, Temperature Humidity at the same time. It provides an
accuracy data for your indoor air quality, and then take a good protection for your stakeholders.
Here is a Wi-Fi function and help you check its real time data at anytime and anywhere on your
cellphone via Meersens Pro App after Wi-Fi pairing.
Air pollution grade scale:
Component introduction:

3
Wi-Fi pairing settings:
After receiving an email with your login information and downloading the Meersens Pro
application from the Apple or Android stores, you can begin the pairing process.
Attention: your network must be a 2.4 GHz Wi-FI network.*Before starting the pairing process,
make sure that your phone is connected to the same network to which you are connecting the
sensor to, that your phone and the sensor are both within 5 meters of the WIFI router, and that
the device is charged.
*If the name of your Wi-Fi network does not indicate whether it is a 2.4 GHZ or 5 GHz network,
you will need to change the frequency of your Wi-Fi or consult your network administrator if
you are a professional.
1. Move the sensor closer to your Wi-Fi router. Then, in the Meersens Proapp on your phone,
go to the home page and scroll down to the “Sensors” section. Add a sensor by clicking on
the “+” icon on the right.
2. Select the model “MMG-174” in the dropdown list.
3. Choose the name of the sensor to identify it more easily later (example: meeting room). To
enter the serial number and the MAC address of your sensor, press the button on top of
the sensor until the QR code appears and scan it. If you are unable to scan it, please enter
the serial number and MAC address manually according to the product label

4
4. Select the sensor current location.
5. Enter WIFI network credentials (name and password) at the Peering step.
Warning: do not click on the “pairing” button until you have completed step 6).
6. Press and hold the grey button on top of the sensor for more than 5 seconds. The Wi-Fi
icon on the product’s screen should blink rapidly. Once the icon is blinking, press the
“Pairing” button. Wait for the pairing process to complete successfully.
Your device is now paired. Click the “Declare New Sensor” button to complete the process.
The first data will appear within the first 10 minutes.
Once paired, the sensor can be safely positioned more than 5 meters from the WIFI router.
(Please note that you may have to try the pairing step again if the first time was unsuccessful).

5
Precautious:
The sensors and chips used in this product are high-precision components, please
keep it away from high temperature and humidity, inflammable gas, liquid environment
when you are using it.
We suggest you to keep the device linking Wi-Fi all the time and then you could check
the data at anytime and anywhere through your cellphone.
•The device adopts over charge protection design. The device can be connected
to the power supply for a long time and continue to charge, without affecting
the battery life, realize 24 hours monitoring.
•Do not make the product bear strong shock and vibration (such as falling from
a high place)
Due to the characteristics of formaldehyde (HCHO) sensor, in order to ensure the
measurement accuracy, please pay attention to the following points before using:
•If you are using it for the first time or if you have not used it for a long time ago,
please take the device out of the box and stay it under ventilated area for 4 hours
and then open the power.
•If the device undergone super-cooling or super-heating environment, the sensor
automatically enters the protective state. Please put it in the normal
temperature environment for 2 hours before starting to use.
•Other non-formaldehyde organic gases (such as alcohol, perfume, pice, oil
paint, smoke, alcohol) will also increase the formaldehyde data of the detector.
Please try to avoid other gas interference when measuring.

www.meersens.com
Meersens is a DeepTech artificial intelligence company specialized in the aggregation
and processing of exposome data in order to help and support communities,
companies involved in CSR issues and health professionals in taking into account the
impact of the environment on the medical condition of individuals. Through its
solution, Meersens acts for Public Health and is part of a virtuous process for the
implementation of advice, prevention actions and decision support in close
collaboration with specialists in the fields concerned.
_______________________________ Based on _________________________________
_______________________________ Partners __________________________________
#HealthGuardian
Discover the Free
Meersens Application
The application, guardian of
your health for a healthier life.
Ask for your demonstration and
ask us all your questions!
SAS Meersens
8 avenue Maréchal Foch, 69006 Lyon
RCS Lyon : 932 811 392 00014
www.meersens.com
Tabla de contenidos
Otros manuales de Monitor de meersens