Me inertialSENSOR ACC5703 Manual de usuario

MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
Königbacher Str. 15 · 94496 Ortenburg / Germany
Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90
ACC5703
Operating Instructions
inertialSENSOR ACC5703

MICRO-EPSILON
MESSTECHNIK
GmbH & Co. KG
Königbacher Strasse 15
94496 Ortenburg / Germany
Tel. +49 (0) 8542 / 168-0
Fax +49 (0) 8542 / 168-90
e-mail [email protected]
www.micro-epsilon.com
3-axes acceleration sensor

ACC5703
Contents
1. Safety ........................................................................................................................................ 5
1.1 Symbols Used ................................................................................................................................................. 5
1.2 Warnings.......................................................................................................................................................... 5
1.3 Notes on CE Marking ...................................................................................................................................... 6
1.4 Intended Use ................................................................................................................................................... 6
1.5 Proper Environment......................................................................................................................................... 7
2. Functional Principle, Technical Data ...................................................................................... 8
2.1 Functional Principle ........................................................................................................................................ 8
2.2 Structure and Electrical Connection................................................................................................................ 8
2.3 Technical Data ................................................................................................................................................. 9
3. Delivery .................................................................................................................................. 12
3.1 Unpacking, Included in Delivery.................................................................................................................... 12
3.2 Storage ......................................................................................................................................................... 12
4. Installation and Assembly...................................................................................................... 13
4.1 Sensor Cable Assembly ................................................................................................................................ 13
4.2 Sensor Assembly........................................................................................................................................... 13
4.3 Pin Assignment.............................................................................................................................................. 15
4.4 Current and Voltage Output .......................................................................................................................... 15
4.4.1 Continuous Operation Mode........................................................................................................ 16
4.4.2 Switching Operation Mode........................................................................................................... 17
4.5 Configuration of Sampling Rate and Low- and High-pass Filter .................................................................. 19
4.6 Digital Output RS485 ..................................................................................................................................... 20
5. Operation ................................................................................................................................ 21
6. Liability for Material Defects ................................................................................................. 21
7. Service, Repair ...................................................................................................................... 22
8. Decommissioning, Disposal ................................................................................................. 22

ACC5703
Appendix
A 1 Accessories ............................................................................................................................ 23
A 2 PC Software sensorTOOL...................................................................................................... 23
A 3 Factory Settings ..................................................................................................................... 23
A 4 Digital Interface RS485 .......................................................................................................... 24
A 4.1 Hardware Interface ........................................................................................................................................ 24
A 4.2 Protocol.......................................................................................................................................................... 24
A 4.2.1 Reading Measurement Data......................................................................................................... 25
A 4.2.2 Example Transmission of a Measurement Value ......................................................................... 29

Page 5
Safety
ACC5703
1. Safety
System operation assumes knowledge of the operating instructions.
1.1 Symbols Used
The following symbols are used in these operating instructions:
Indicates a hazardous situation which, if not avoided,
may result in minor or moderate injury.
Indicates a situation that may result in property damage if not avoided.
Indicates a user action.
iIndicates a tip for users.
1.2 Warnings
Connect the power supply and the display/output device according to the safety regulations for electrical
equipment.
> Risk of injury
> Damage to or destruction of the sensor
The supply voltage must not exceed the specified limits.
> Damage to or destruction of the sensor
No sharp or heavy objects should be allowed to affect the cables. Avoid folding the cables. Do not bend
more tightly than the minimum bending radius of the cables.
> Damage or destruction of the cable, failure of the measuring device
Do not crush the cable. Protect the sensor cable against damage.
> Damage or destruction of the cable, failure of the measuring device, data loss
Ensure that the coupling nuts of the connectors are firmly tightened.
> Damage or destruction of the cable, failure of the measuring device

Page 6
Safety
ACC5703
1.3 Notes on CE Marking
The following apply to the ACC5703:
- EU Directive 2014/30/EU
- EU Directive 2011/65/EU
Products which carry the CE mark satisfy the requirements of the EU directives cited and the European
harmonized standards (EN) listed therein. The EU Declaration of Conformity is available to the responsible
authorities according to EU Directive, article 10, at:
MICRO-EPSILON MESSTECHNIK
GmbH & Co. KG
Königbacher Straße 15
94496 Ortenburg /Germany
The measuring system is designed for use in industrial environments and meets the requirements.
1.4 Intended Use
The ACC5703 is designed for use in industrial applications. It is used for
measuring acceleration
measuring vibration of manoeuvrable components
- The system must only be operated within the limits specified in the technical data, see 2.3.
- The sensor must be used in such a way that no persons are endangered or machines and other material
goods are damaged in the event of malfunction or total failure of the sensor.
- Take additional precautions for safety and damage prevention in case of safety-related applications.

Page 7
Safety
ACC5703
1.5 Proper Environment
- Protection class: 1IP 67
- Operating temperature: -40 ... +85 °C (-40 ... +185 °F)
- Storage temperature: -40 ... +85 °C (-40 ... +185 °F)
- Ambient pressure: Atmospheric pressure
1) With M12 connector

Page 8
Functional Principle, Technical Data
ACC5703
2. Functional Principle, Technical Data
2.1 Functional Principle
With the principle of an acceleration sensor, forces that change the velocity of an object are measured and
transformed into an electric output signal.
Therefore the sensor is mounted on the maneuverable component. The expected moves correspond to the
measurement axes. The included MEMS-Element converts the acceleration into a usable electric signal.
-z
+z -x
+x
-y
+y
Fig. 1 Three axes acceleration sensor
2.2 Structure and Electrical Connection
The sensor is ready for operation immediately after connecting the power supply and will provide the accel-
eration as electric value at the analog output.
The ACC5703 is available with analog (current, voltage and switching output) as well as RS485 interface for
configuring of the sensor using the software.
Power supply and signal output are connected through a 8-contact (M12) connector on the sensor’s housing.

Page 9
Functional Principle, Technical Data
ACC5703
2.3 Technical Data
Model ACC5703-8
Number of axes 3
Measuring range ± 0 g … ± 8 g (configurable)
Resolution Digital 0.016 mg
Analog Current: < 0.24 mg / voltage < 0.31 mg
Noise Typ. 30 µg / √Hz
Sensitivity
(analog output)
Current < 4 mA/g
Voltage < 1 V/g
Zero 12 mA or 2.5 V
Linearity Typ. 0.45 % FSO
Frequency range 0 ... 1000 Hz (configurable)
Sampling rate Up to 4 kHz
Cross axis sensitivity 1 % FSO
Temperature stability Typ. ± 0.2 mg / K
Supply voltage 5 … 32 VDC
Power consumption < 3 W
Temperature range Operation -40 … +85 °C (-40 ... +185 °F)
Storage -40 … +85 °C (-40 ... +185 °F)
Digital interface RS485
Analog output Current 4 … 20 mA (max. 390 Ω)
Voltage 0.5 … 4.5 V (min. 1 KΩ)
Switching output 0 / 5 V (min. 1 KΩ)
Protection class IP 67 (plugged state)

Page 10
Functional Principle, Technical Data
ACC5703
Model ACC5703-8
Shock DIN EN 60068-2-27
(1500 g, 0.5 ms, half-sine shock, 3 x in each direction)
Weight Approx. 250 g
Material Die-cast aluminum
Installation Screw connection via mounting holes (M4)
Connection M12 connector, 8-pin
Start-up time < 500 ms
FSO = Full Scale Output
All specifications valid at a room temperature of +25 °C (+77 °F)
Article designation
ACC 5703 -8 -SA -U/I
Output
U = voltage 0.5 ... 4.5 V,
I = current 4 ... 20 mA,
switching output 0 / 5 V
Connection:
SA = axial plug
Measuring range in g
High Performance acceleration sensor
Tabla de contenidos
Otros manuales de Accesorios de Me