Thank You for purchasing a Maytag water heater. Properly installed
and maintained, it should give you years of trouble free service. It is
strongly suggested that this new water heater be professionally
installed, contact Maytag Customer Service (1-800-788-8899) for
recommended installers.
AbbreviationsFoundInThisInstructionManual:
• CSA-CanadianStandardsAssociation
• ANSI-AmericanNational StandardsInstitute
• NFPA- NationalFireProtectionAssociation
• ASME-AmericanSocietyofMechanicalEngineers
• GAMA- GasApplianceManufacturer’sAssociation
• UL- UnderwritersLaboratoriesInc.
Thisgas-firedwater heateris listedby UnderwritersLaboratoriesInc.
underAmericanNationalStandard/CSAStandardforGasWaterHeaters
ANSIZ21.10.1 •CSA4.1(currentedition).
PREPARINGFORTHEINSTALLATION
1. Read the“SafetyPrecautions” section,page3 ofthismanual first
andthenthe entiremanualcarefully. If youdon’tfollow thesafety
rules, the water heater will not operate properly. It could cause
DEATH,SERIOUSBODILYINJURYAND/ORPROPERTYDAMAGE.
Thismanualcontainsinstructionsfor theinstallation,operation, and
maintenanceofthe gas-firedwaterheater. Italsocontainswarnings
throughout the manual that you must read and be aware of. All
warningsandall instructionsare essential tothe properoperation
ofthewaterheaterandyoursafety. Sincewecannotputeverything
on the first few pages, READ THE ENTIRE MANUAL BEFORE
ATTEMPTINGTOINSTALLOROPERATETHEWATERHEATER.
2. The installation must conform with these instructions and the local
code authority having jurisdiction. In the absence of local codes,
installationsshallcomplywiththeNationalFuelGasCodeANSIZ223.1/
NFPA54andtheNationalElectricalCode,NFPA70.Thesepublications
are available from The National Fire Protection Association, 1
BatterymarchPark,Quincy,MA02269.
3. The waterheaterwhen installedmust begrounded inaccordance
withthelocal codes,orin theabsenceof localcodes,the National
ElectricalCodeNFPA70.
4. Ifafterreadingthismanualyouhaveanyquestionsordonotunderstand
anyportionoftheinstructions,callthelocalgasutilityorMaytagCustomer
Service at 1-800-788-8899 for an authorized servicer.
5. Carefullyplantheplacewhereyouaregoing toputthewaterheater.
Correct combustion,vent action,andventpipeinstallation arevery
important in preventing death from possible carbon monoxide
poisoningand fires.
Examinethelocationtoensure thewater heatercomplies withthe
“FactstoConsiderAboutthe Location”section inthis manual.
6. ForCaliforniainstallationthiswaterheatermustbebraced,anchored,
or strapped to avoid falling or moving during an earthquake. See
instructionsfor correctinstallationprocedures. Instructionsmaybe
obtained from California Office of the StateArchitect, 400 P Street,
Sacramento,CA95814.
7. Massachusetts Code requires this water heater to be installed in
accordancewithMassachusetts248-CMR2.00:StatePlumbingCode
and248-CMR5.00.Formore informationseenext page.
8. Complieswith SCAQMDrule#1121 anddistrictshaving equivalent
NOxrequirements.
CUSTOMER RESPONSIBILITIES
PRODUCT SPECIFICATIONS
TANK RECOVERY MINIMUM
CAPACITY INPUT RATE GALS. VENTPIPE DIAMETER DIMENSIONSIN
MODEL IN GALS. TYPEOF RATE PERHOUR INCHES INCHES INCHES(mm)HEIGHT
NUMBER (LTRS) GAS (Btu/hr) @90°FRISE (mm) (mm) TOJACKETTOP
HVN41240P 40 (151) NATURAL 40,000 44 2 (51) 201/2(521) 55(1,397)
HVN41250P 50 (189) NATURAL 40,000 44 2 (51) 22(559) 563/4(1,441)
HVN41250V 50 (189) NATURAL 50,000 53 2 (51) 22(559) 56 3/4(1,441)
HVP41240P 40 (151) PROPANE 40,000 44 2 (51) 201/2(521) 55(1,397)
HVP41250P 50 (189) PROPANE 40,000 44 2 (51) 22(559) 563/4(1,441)
HVP41250V 50 (189) PROPANE 50,000 53 2 (51) 22(559) 563/4 (1,441)