Master MGY5000 Guía de inicio rápido

PORTABLE DIESEL
GENERATOR
OWNER’S OPERATION AND INSTALLATION MANUAL
R
IMPORTANT
Read and understand this manual before operating or servicing
generator. Improper use of generator can cause serious injury.
Keep this manual for future reference.
Generator Model: MGY5000
RUN
STOP
EF
RESET
TEST
RESET
120 VOLTS
FULL POWER
SELECTOR
120
ONLY 120
240V
120/240 VOLTS
RESET
RESET

2
SECTION PAGE
Safety Information........................................................................... 3
Product Identification ...................................................................... 6
General Information ........................................................................ 7
Specifications .................................................................................. 7
Unpacking........................................................................................ 7
Ventilation ....................................................................................... 8
Dust, Dirt, Rain, and Snow.............................................................. 8
High and Low Temperature Operation............................................ 8
Generator Features........................................................................... 8
Oil Alert System ....................................................................... 8
Battery Discharge Lamp ........................................................... 9
Full Power Selector Switch....................................................... 9
Ground Fault Circuit Interrupter Receptacle ........................... 10
Electric Start............................................................................. 10
Receptacle Circuit Breaker ...................................................... 11
Spark Arrester .......................................................................... 11
Engine Oil....................................................................................... 12
Fuel ................................................................................................. 13
Battery ............................................................................................ 13
Generator Grounding...................................................................... 16
Extension Cords.............................................................................. 17
Standby Installation To Home or Building .................................... 17
Determining Electrical Load For Generator................................... 18
Operation ........................................................................................ 19
General Information................................................................. 19
Using Receptacle ..................................................................... 19
Power Cord and Plug Requirements ........................................ 20
Prestart ..................................................................................... 21
Bleeding Fuel Line................................................................... 21
Starting ..................................................................................... 21
High Altitude Operation .......................................................... 24
Adding Electrical Loads .......................................................... 24
Disconnecting Electrical Loads ............................................... 25
Stopping Engine....................................................................... 25
Maintenance and Repairs ............................................................... 26
Storage ............................................................................................ 26
Troubleshooting.............................................................................. 27
Electrical Component Specifications ............................................. 27
Wiring Diagrams ............................................................................ 28
Technical Service ........................................................................... 29
Servicing the Engine....................................................................... 29
Replacement Parts .......................................................................... 29
Accessory ....................................................................................... 29
Illustrated Parts Lists ................................................................... 30-33
Warranty Information ........................................................ Back Cover
CONTENTS

3
SAFETY
INFORMATION
!
WARNING ICON G 001
WARNINGS
IMPORTANT: Read this owner’s manual and the engine owner’s
manual carefully. Become familiar with this generator before trying to
operate or service it. Know its uses, limitations, and any hazards
involved. Improper use of generator can cause severe injury or death
from explosion, fire, burns, electrical shock, or carbon monoxide
poisoning.
!
WARNING ICON G 001
DANGER
Carbon monoxide poisoning may lead to death!
Engine exhaust contains poisonous carbon monoxide gas. Overexposure will
cause loss of consciousness and will lead to death. Use only in well-vented areas.
Make sure area has plenty of free-moving, fresh, outside air. Never run generator
in an enclosed or confined area. Never run generator inside occupied building.
Early signs of carbon monoxide poisoning resemble the flu, with headaches,
dizziness, and nausea. If you have these signs, get fresh air at once! Some people
are more affected by carbon monoxide than others. These include pregnant
women, persons with heart or lung disease or anemia, those under the influence of
alcohol, and those at high altitudes. Make certain you read and understand all
warnings. Keep this manual for reference. It is your guide to safe and proper
operation of this generator.
Safety information appears throughout these instructions. Pay close attention to
them. Below are definitions for the safety information listed throughout this
manual.
DANGER indicates a hazard which will cause severe personal injury,
death, or substantial property damage if you ignore warning.
WARNING indicates a hazard which can cause severe personal injury,
death, or substantial property damage if you ignore warning.
CAUTION indicates a hazard which will or can cause minor personal
injury or property damage if you ignore warning.
Continued
1.!DANGER Diesel fuel presents a hazard of fire. Diesel fuel is flammable.
• Keep fuel out of children’s reach.
• Refuel generator in a well-vented area. Do not fill fuel tank in the dark. Do
not refuel while engine is running. Unhook all electrical loads and shut off
engine before refueling.
• Do not overfill fuel tank. Always allow room for fuel to expand. If you
overfill tank, fuel can overflow onto hot generator. This can cause fire.
After refueling, tightly close fuel tank cap.
• Do not spill fuel. If fuel spills, make sure area is dry before starting engine.
• Never smoke in refueling area. Never allow open flames or sparks in area.
• Store fuel in approved container. Store fuel in a well-vented area free of
open flames or sparks.

4
SAFETY
INFORMATION
Continued
2. !WARNING Guard against fire hazard. Keep operation area well-vented.
Keep generator at least three feet away from any object. Do not place flam-
mable objects near generator.
• Do not use generator where flammable vapors are present. Some vapors are
heavier than air. These vapors settle in low-lying places.
• Do not use generator in enclosed spaces. This includes motor home or RV
generator compartments.
3. !WARNING Guard against electric shock. Generator produces high volt-
age. This high voltage can cause severe electric shock. Only responsible adults
should use the generator.
• Properly ground generator before starting.
• Never let anyone operate or service generator without proper instructions.
• Avoid contact with live terminals or bare wires.
• Do not use generator outdoors in rain or snow.
• Do not use generator near standing water or snow.
• Do not use if generator is wet or damp.
• Do not use generator in highly conductive areas. These areas include metal
decking and steelwork.
• Only use grounded extension cords.
• Do not use any worn or damaged electric cords. Electric shock or damage to
generator may result.
• Do not wear damp clothing or wet shoes when using generator.
4. !WARNING Guard against burns. Hot engine parts can cause severe injury.
Use caution and remain alert when using generator.
• Keep children and animals away from generator while it is running or hot.
• Keep all covers and shields in place. Keep them tightly secured.
• The muffler becomes very hot during operation. The muffler remains hot
for a while after shutdown. Do not touch muffler while it is hot. Do not let
muffler touch anything flammable. Let engine cool before transporting or
storing.
5. !WARNING Have standby installation to home or building performed by a
licensed electrician. Do not let anyone else wire into a utility circuit. Personal
injury, equipment damage, or damage to home could occur.
6. !WARNING Never connect generator to any existing electrical circuits. The
generator output will back-feed into the utility power line. This may electro-
cute a power company line repair person. Also, if generator is powering
electrical circuits, the chance of an electrical fire exists.
7. !WARNING Battery gives off explosive gases. Keep sparks, flames, and
cigarettes away. Do not remove or install battery cables when engine is
cranking or running. Only service or use battery in a well-vented area.

5
SAFETY
INFORMATION
Continued
8. !WARNING Battery contains sulfuric acid. Battery acid is poisonous if
swallowed. Contact with skin or eyes may cause severe burns. Do not tilt
generator with battery installed. Tilting could cause battery acid to spill.
Wear protective clothing and face shield when servicing. Keep out of
children’s reach.
9. !WARNING Only a qualified electrical service person should service and
repair generator.
• Generator produces high voltage. Use extreme caution when working on
electrical parts.
• When working on generator, avoid hot muffler, exhaust manifold, and
engine parts. Severe burns may occur.
• Do not work on generator when tired.
• Use only factory approved replacement parts.
10. !WARNING Store generator in a well-vented area. Make sure fuel tank is
empty. Never store with fuel in tank.
11.
!
CAUTION
Never operate generator
• if engine speed changes greatly
• if engine misfires often
• if powered items overheat
• if electrical output drops
• if it is sparking
• if it produces smoke or flames
• if it vibrates at high levels
• if it has a damaged receptacle
12.
!
CAUTION
Keep generator and nearby areas clean.
• Keep generator free of oil, mud, and other foreign matter.
• Remove anything that creates slippery areas around generator.
• Remove oily rags and other items that create fire hazards.
• Keep a fire extinguisher nearby. Make sure it is rated ABC by the NFPA.
They are good for all uses. Consult your local fire department.
• Keep fire extinguisher well maintained. Be familiar with its use.
13.
!
CAUTION
Know how to stop engine quickly. Know how to use all
controls.
14.
!
CAUTION
Prolonged exposure to loud noise can cause hearing loss.
• When working around generator, wear approved hearing protection.
• Remember neighbors when using generator.

6
EF
RUN
STOP
EF
RESET
TEST
RESET
120VOLTS
FULLPOWER
SELECTOR
120
ONLY 120
240V
120/240VOLTS
RESET
RESET
PRODUCT
IDENTIFICATION
Figure 1 - Portable Generator
Control
Panel
Roll Cage
Alternator
Engine
Run Lever
Electric Start
Switch
Fuel Valve
(under fuel
tank)
Engine
Stop Lever
Circuit
Breaker
Decompression
Lever
Starter Grip
Fuel Gage
Fuel Cap
Fuel Tank
Ground
Lug
Spark
Arrester
Muffler
Oil Dipstick
Engine
Battery
Discharge
Lamp
Oil Alert
Lamp
120 Volt
Receptacle
120 Volt
Receptacle
(GFCI)
Run Lamp
120/240 Volt
Receptacle
Full Power
Selector Switch

7
This portable generator is rugged and compact. It provides dependable, trouble-free
service. The alternator is brushless with revolving fields. Yanmar diesel engine
provides long life under heavy use. This engine is governed to maintain engine
speed of 3600 RPM under load. 3600 RPM engine speed provides 120/240V, 60
Hz power.
Additional Features
• Circuit breaker protection
• Spark-arresting muffler
• Large fuel tank
• Oil alert system
• Electric starter
• Pressurized lubrication system
• 15-Amp ground fault circuit interrupter (GFCI) receptacle
GENERAL
INFORMATION
SPECIFICATIONS MODEL MGY5000
Electrical Specifications
Rated Wattage* 5000
Rated Amperage
120 Volt 41.7
240 Volt 20.8
Receptacle Specifications
120-Volt, 15-Amp GFCI Yes
120-Volt, 30-Amp Twist-Lock Yes
120/240-Volt, 20-Amp Twist-lock Yes
120-Volt Full-Power Switch Yes
General Specifications
Yanmar Engine H.P. 9
Yanmar Engine Model L90
Fuel Type Diesel
Fuel Tank Capacity 4.2 Gallons
Oil Alert System Yes
Electric Start Yes
Weight (pounds) 241
* Single-phase, 1.0 power factor
UNPACKING 1. Remove generator from carton.
2. Remove any protective packaging applied to generator for shipment.
3. Check for loose or missing parts. Check for shipping damage. If any parts are
missing or damaged, promptly inform dealer where you bought generator.
4. Battery cables are in a separate bag inside generator carton. You must install
these cables to engine. See Battery, page 13 for installation instructions.

8
WARNING ICON G 001
DANGER
Use only in well-vented areas. Make sure area has
plenty of free-moving, fresh, outside air. Never run
generator in an enclosed or confined area. Never run
generator inside occupied building. Engine exhaust
contains poisonous carbon monoxide gas.
Overexposure will cause loss of consciousness and
will lead to death.
VENTILATION
This generator needs cooling air to run properly. Never block free-flowing, cooling
air to generator. Overheating will occur without cooling air. This will damage the
generator. Keep generator at least three feet away from any object.
WARNING ICON G001
DANGER
Do not use generator outdoors in rain or snow. Do
not use generator near standing water or snow. Do
not use if generator is wet or damp. Operating
generator in these conditions increases the risk of
electrocution. Severe injury or death can occur.
DUST, DIRT,
RAIN, AND
SNOW
Do not use generator in extremely dusty or dirty conditions. This will severely
affect its life. Keep generator clean. Do not allow dust, dirt, rain, or snow to collect
on it. Protect generator from outdoor elements.
Air temperature affects generator output. Output drops 1% for each 10°tempera-
ture rise above 60°F. Low temperatures may make the engine hard to start. See
engine owner’s manual for more information.
HIGH AND LOW
TEMPERATURE
OPERATION
GENERATOR
FEATURES
OIL ALERT SYSTEM
The oil alert system protects the engine from low oil damage. This system auto-
matically shuts down the engine and prevents engine restarting if the oil pressure
falls too low.
If this system shuts down the engine, the engine will not start until you add oil. The
oil alert lamp is near engine starter switch (see Figure 2, page 9). Add oil to engine
(see Engine Oil, page 12).
See engine owner’s manual for more information.

9
CHARGE
OFF OIL
Battery
Discharge
Lamp
Oil Alert
Lamp
Figure 2 - Battery Discharge Lamp and Oil Alert Lamp Location
Continued
GENERATOR
FEATURES
Continued
FULL POWER SELECTOR SWITCH
The full power selector switch is on the control panel. The switch has two posi-
tions: 120 VOLT ONLY, and 120/240 VOLT.
120 VOLT ONLY: This position sends full power to the 120V receptacles only.
240V power is not available. Use this position when powering 120V items only.
120/240 VOLT: This position sends full power to the 120/240V receptacle. It also
powers the 120V receptacles at reduced wattage capacity.
IMPORTANT:
Do not move the full power selector switch while powering
electrical items. Unplug all items before moving switch. Failure to do so can
damage switch.
BATTERY DISCHARGE LAMP
The battery discharge lamp (see Figure 2, above) will light if battery charger is not
operating while engine is running. If this happens, the battery will not charge and
will eventually run down. Have battery charging circuit repaired by authorized
service person.
120V
ONLY 120
240V
FULL POWER
SELECTOR
120V
ONLY 120
240V
FULL POWER
SELECTOR
120 VOLT ONLY
Position 120/240 VOLT
Position
Figure 3 - Full Power Selector Switch

10
GENERATOR
FEATURES
Continued
GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE
This generator has a 120-volt ground fault circuit interrupter (GFCI) receptacle.
The GFCI receptacle is on the control panel. The GFCI protects you against
hazardous electrical shock caused when your body becomes a path through which
electricity travels to reach ground. This could happen when you touch an appli-
ance or cord that is ‘live’ through faulty mechanism, damp or worn insulation, etc.
When protected by the GFCI, you may still feel a shock, but the GFCI should cut
it off quickly. A person in normal health should not receive serious injury.
Note:
Infants and very small children may still be affected.
Test Procedure
Check the GFCI receptacle every month. This insures it is working right.
1. PushblackTESTbutton.RedRESETbuttonshouldpopout.ThisshouldtripGFCI,
resulting in no electrical power at receptacle. Verify this by plugging test lamp
with good bulb into receptacle. If lamp does not work, GFCI receptacle is good.
!
WARNING ICON G 001
WARNING
IfRESET button doesnotpopout, donotusethe GFCI
receptacle. Contact a qualified electrician for repairs.
2. If the GFCI receptacle tests okay, restore power by pushing the RESET button
back in. The test lamp should work at this time.
IMPORTANT:
You must
press the RESET button firmly and fully. It should lock into place. If the GFCI
does not lock into place, do not use receptacle. Contact a qualified electrician
for repairs.
RESET
TEST
ELECTRIC START
This model has an electric starter. A battery is not supplied with generator. You
must provide a 12-volt, 45-amp-hour battery. For more battery information, see
Battery, page 13.
Figure 4 - GFCI Receptacle
Tabla de contenidos
Otros manuales de Generador portátil de Master

Master
Master LP 10 kW M Manual de usuario

Master
Master MGH3000 Guía de inicio rápido

Master
Master MGY5000C Guía de inicio rápido

Master
Master MGY5000C Guía de inicio rápido

Master
Master MGR2900, MGR4500I, MGR6000I Guía de inicio rápido

Master
Master HWI3000 Guía de inicio rápido

Master
Master HWI3000 Guía de inicio rápido

Master
Master MGH10000C Guía de inicio rápido

Master
Master MGH8500IE Guía de inicio rápido

Master
Master MGR2900, MGR4500I, MGR6000I Guía de inicio rápido