1. Introduction
Volteq HY series single output switch mode DC power supplies are regulated variable DC power supplies
designed to provide the most often required DC outputs in scientific and research institutions, schools and colleges,
industrial R&D, as well as manufacturing and testing.
The output voltage is continuously adjustable between 0 and the rated voltage by means of the coarse and fine
potentiometers; the output current is continuously adjustable between 0 and the rated current by means of a current
adjustment knob. Both outputs are accurately displayed on the digital voltmeter and ammeter.
The DC power supplies in this series have high efficiency, superior load and line regulation, and low ripple noise.
These power supplies have high level of protection including over voltage, over temperature, and over load protection.
They can act as constant voltage as well as constant current sources. Because of the excellent protection, these power
supplies are widely used for electroplating, anodizing, electroforming, electro-winning, battery charging and
equalizing, and other applications requiring excellent reliability and robustness.
2. Specifications
2-1 General
AC Input 110V/220V, 110V, or 220V ±10%, 50/60 Hz
Rating See table 2-1
Operating environment: Indoor use with dry and dust-free air for cooling
Altitude: up to 2000 m

Temperature: -10°C to 40°C
Relative humidity: <80%
Table 2-1
Model Max. Voltage Max. Current Fuse Rating Weight (lbs)
HY1520EX 15V 20A 10A/250V 14
HY1530EX 15V 30A 10A/250V 15
HY3010EX 30V 10A 10A/250V 14
HY3020EX 30V 20A 10A/250V 15
HY3030EX 30V 30A 15A/250V 15
HY5020EX 50V 20A 15A/250V 17
HY6020EX 60V 20A 15A/250V 16
2-2 Front Panel Descriptions
(1) Trademark: Volteq.
(2) Digital ammeter: displays the actual output always; this equates to the set value if in CC mode.
(3) Current knob (Coarse): for coarse adjustment of current limit.
(4) Current knob (Fine): for fine adjustment of current limit.
(5) CC indicator light: this indicator turns red when the power supply is in constant current (CC) mode (See 3-2).

(6) OV indicator: this indicator turns red when the power supply is over-voltage protected. The power supply will not
respond to user control until it's reset (See 4-2).
(7) On/Off Power button: When this button is pushed to "In" position, the power supply is turned on; conversely, the
power supply is off when this button is in the "Out" position.
Note: For models with air switch, this button enables/disables the output. Turn the air switch on first
before turning this button on; conversely, turn this button off before switching off the air switch in the back. For
the models without air switch, this button turns the power on and off.
(8) Front output terminals: from left to right, labeled as negative, ground ("GND"), and positive. The output is between
the + and - terminals, while the ground terminal is for grounding the case only. To reduce the ripple, the negative

output terminal ("-") is usually shorted with “GND”. Only select models include the front terminals.
Warning: the front terminals are rated for less than 10A only. Use only the rear output terminals if current
draw is more than 10A, and tighten the connection to reduce contact resistance.
Warning: For electrochemical applications (e.g., plating and anodizing), remove the short connector
between “–” and ground terminals.
(9) Model number: shows the actual model number of the power supply.
(10) Digital voltmeter: Displays the actual output voltage always; this equates to the set value when in CV mode.
(11) OV Adjustment: for setting the OV (over-voltage) level (See 3-5) with a flat head screwdriver (not included).
(12) Voltage Adjustment (fine): for the fine adjustment of the voltage limit.
(13) Voltage Adjustment (coarse): for the coarse adjustment of the voltage limit.
(14) CV indicator: this indicator light turns red when the power supply is in constant voltage (CV) mode (See 3-2).
(15) Over-temperature (OT) indicator: this indicator turns red when the internal temperature of the power supply is too
high, and the power supply output is disabled. See 4-3 for more details.
2-3 Back Panel Descriptions

(16) Positive Terminal.
(17) Negative Terminal.
(18) Ground Terminal: this is connected to the case.
(19) Cooling fan: the fan is turned on briefly when the power supply is energized; afterwards it is turned on when
internal temperature of the power supply rises above 45℃.
(20) AC voltage selector switch: use this switch to select the input AC of either 110V or 220V for select models.
Warning: To avoid electrical shock, the power plug ground pin must be connected to AC ground.
Warning: the voltage indicated on the power supply must match the AC voltage, otherwise the power supply
will be damaged (plugging a power supply rated for 110V into 220V AC), or the maximum output would not be
reached (plugging a 220V power supply into 110V AC).
(21) AC Input. For power supply models not equipped with air switch, the fuse is located here. To replace the fuse,
remove the AC power cord, and use a flat head screwdriver to remove the fuse holder.

2-3 Technical Parameters
1) Voltage stabilization: ≤0.2%
2) Current stabilization: ≤0.5%
3) Load stabilization: ≤0.3%
4) Ripple and noise: ≤1%( RMS)
5) Display accuracy: ±1%±1 digit
3. Operation Instructions
3-1 Installation
1) Before plugging into AC outlet
The input voltage of the power supply is typically shown on the top rear part of the case. AC voltage should be within
10% of the input voltage specified, e.g., if the specified input voltage is 110V, the power supply will work with AC
voltage of 110V±10%.
Warning: The voltage indicated on the power supply (look for a sticker on the case close to the rear) must match
the AC voltage, otherwise the power supply will be damaged (plugging a power supply rated for 110V into 220V AC;
such damages are not under warranty), or the maximum output will not be reached (plugging a 220V power supply
into 110V AC). If the power supply is equipped with an AC voltage selector switch in the back, the selector switch
must show the correct value in the middle, e.g. for 120V AC, the switch itself should show 110V in the voltage

selector switch as shown in picture below:
Warning: Changing the AC voltage selector setting must be done with the power supply unplugged from AC.
Warning: To avoid electrical shock, the grounding conductor of the power cord must be connected to AC ground.
Warning: Do not connect any load to the power supply before it's turned on. Likewise, make sure to disconnect
the load before shutting down the power supply. Shutting down improperly can cause the power supply to fail when
it’s turned on next time. Damages due to improper startup and/or shutdown are not under warranty.
Warning: When running an inductive load like magnetic coils, DC motors, stepper motors, etc., make sure to set
the output to zero before connecting the load, change the voltage/current slowly, and NEVER turn the power supply
on or off with a inductive load connected!
2) Installation: For better heat dissipation, the two sides and back of the power supply should have at least 10cm space
from the walls. The cooling fan is controlled by thermistor and will turn on automatically when the temperature of the
heat sink is above 45°C. The power supply comes with over-temperature (OT) protection, and will disable itself when
the inside temperature of the device is too high. The power supply resets itself once the temperature falls below the
40°C. To ensure proper operation, make sure the ambient temperature is below 40°C and there is sufficient ventilation.

3-2 Constant Voltage / Constant Current Characteristics
The power supply is a regulated constant current / constant voltage (CC CV) power supply, which is
characterized by automatic crossover from constant current (CC) to constant voltage (CV), and vise versa. At any
moment, the power supply automatically determines whether to operate in CV or CC mode, depending on the voltage
and current limit (set by the front knobs), and the load connected (if no load is connected, it simply means that the load
resistance is infinite; conversely, if a short is connected, the load resistance is zero).
Note: The power supply is in CC mode if indicator light 5 is on; it’s in CV mode if indicator light 14 is on.
In order to understand the crossover, it is important to note that the voltage and the current are related by the
Ohm’s law, so only one of the two is an independent variable. The law dictates that the output current I in amps (A) is
always equal to the output voltage V in volts (V) divided by the load resistance R in ohms (Ω):
For example, if the load resistance (R) is such that the current limit (set by knobs 3 and 4) is higher than the
voltage limit (set by knobs 12 and 13) divided by R (i.e., voltage limit is lower than current limit for the load R
connected), the power supply operates in the constant voltage (CV) mode. When in CV mode, the output voltage
remains constant even if the load resistance changes (e.g., if load resistance decreases, the current increases), up to the
point when the preset current limit is reached. The crossover point is reached when the voltage and current limit are
reached simultaneously. Beyond the crossover point, the indicator changes from CV to CC, and the current limit

becomes the lower limit, and the output current remains constant and the output voltage drops in proportion to the
further decrease of the load resistance.
Similarly, crossover from constant current (CC) to constant voltage (CV) mode automatically occurs when the
resistance of the load is increased. A good example of this behavior is charging a 12V lead acid battery. Initially, the
open circuit voltage of the power supply may be set at 13.8V. A discharged battery when connected to the power
supply may demand high charging current beyond the current limit set for the power supply (or the maximum current
capacity of the power supply), and the power supply will operate in constant current mode, with the maximum
charging current equal to the set current limit. As the battery becomes more charged, the voltage will increase, and
eventually reach 13.8V. Beyond that point, the current demand from the battery will drop and fall below the set limit.
The crossover is signaled by the indicator light change from CC to CV.
3-3 Operating Procedures
a) With the power switched off, leave the OV limit (11) to maximum position (factory default) or adjust per
instructions at 3-5.
b) Make sure that the AC line voltage matches the input voltage of the power supply.
c) Make sure there is no load connected, plug power cord into the AC outlet.
d) Turn the power supply on.
Caution: For models with air switch, the green On/Off button enables/disables the output. Turn on the air
Este manual sirve para los siguientes modelos
6
Tabla de contenidos
Otros manuales de Fuente de alimentación de Mastech

Mastech
Mastech HY1503D Manual de usuario

Mastech
Mastech HY1503D Manual de usuario

Mastech
Mastech HY1803D Manual de usuario

Mastech
Mastech HY3010E Manual de usuario

Mastech
Mastech HY3000M Series Manual de usuario

Mastech
Mastech HY3000 double series Manual de usuario

Mastech
Mastech HY3003D Manual de usuario

Mastech
Mastech HY3003D Manual de usuario