Marport Catch Sensor Manual de usuario

Catch Sensors
Service Manual


Contents | iii
Contents
Legal...................................................................................... 5
Disclaimer................................................................................................................................................ 5
Copyright..................................................................................................................................................5
History.......................................................................................................................................................5
Introduction and Presentation............................................... 6
Introduction............................................................................................................................................ 6
Applications.............................................................................................................................................7
Safety Guidelines.................................................................................................................................10
Description..............................................................................................................................................11
Firmware..................................................................................................................................... 11
Technical Specifications....................................................................................................... 13
Main Parts................................................................................................................................. 16
Operational Mode Indicator................................................................................................18
Installation Steps................................................................................................................................ 19
Sensor Configuration........................................................... 20
Installing Mosa....................................................................................................................................20
Connecting the Sensor to Mosa.................................................................................................... 21
Calibrating the Catch Sensor......................................................................................................... 22
Testing the Catch Sensor on Mosa............................................................................................. 24
Catch Explorer Specific Settings.................................................................................................. 25
Configuring the Uplink and Down Settings.................................................................25
Configuring the Noise Floor.............................................................................................. 27
Calibrating the Sensor for Target Strength Value.....................................................28
Canceling the Ringing...........................................................................................................31
Configuring Catch Sensor Telegrams......................................................................................... 33
Catch............................................................................................................................................ 33
Temperature............................................................................................................................. 33
Depth........................................................................................................................................... 34
Pitch and Roll..........................................................................................................................34
Catch Hybrid PI.......................................................................................................................35
Catch Hybrid 70......................................................................................................................35
Configuring the Uplink Power.......................................................................................................36
Testing Measures................................................................................................................................37
Updating the Sensor..........................................................................................................................39
Downloading the Firmware................................................................................................39
Updating the Sensor............................................................................................................. 39
Exporting Configuration Settings for Record Keeping........................................................40
Exporting Sensor Configuration for Receiver..........................................................................41
System Configuration and Display....................................... 43
Adding the Sensor to the Receiver..............................................................................................43
Adding the Sensor with a Configuration File..............................................................43
Adding the Sensor Manually.............................................................................................44
Adding the Sensor to the Receiver..................................................................... 44

Configuring the Sensor Settings..........................................................................45
Configuring Data Display on Scala............................................................................................. 49
Installation...........................................................................54
Installing the Sensor on the Trawl.............................................................................................54
Servicing and Maintenance.................................................. 57
Interference Check............................................................................................................................. 57
Spectrum Analyzer Display................................................................................................ 57
Checking Noise Interference..............................................................................................57
Charging the Sensor..........................................................................................................................59
Maintenance.........................................................................................................................................60
Cleaning the Sensor..............................................................................................................60
Maintenance Checklist..........................................................................................................61
Replacing Parts.................................................................................................................................... 61
Replacing the Battery............................................................................................................61
Replacing the Pull Cords.....................................................................................................65
Replacing the Catch Magnet............................................................................................. 66
Replacing the Shoulder Bolts............................................................................................68
Replacing the Temperature Sensor.................................................................................72
Replacing the Pressure Sensor..........................................................................................77
Replacing the Pressure Sensor............................................................................. 77
Updating the Depth Coefficients..........................................................................83
Replacing the Transducer...................................................................................................84
Troubleshooting..................................................................................................................................88
Firmware downloaded on DealerWeb cannot be read by Mosa............................88
Mosa does not start due to error message.................................................................. 88
Data in Scala is wrong.........................................................................................................88
Echogram is fixed and blue...............................................................................................89
Sensor has difficulty connecting to Mosa....................................................................89
Catch Explorer images are incorrect when beginning towing..............................89
Catch status remains full or empty................................................................................90
Support Contact...................................................................................................................................91
Appendix A: Frequency Plan.................................................92
Appendix B: Examples of Installations for a Target Strength
Calibration........................................................................ 94
Index.................................................................................................... 97

Catch Sensors | V1 | Legal
Legal
Disclaimer
Marport endeavour to ensure that all information in this document is correct and fairly
stated, but does not accept liability for any errors or omissions.
Copyright
© 2016-2017 Marport. All Rights reserved.
No part of this document may be reproduced, stored in a retrieval system or transmitted
in any form by any means; electronic, mechanical, photocopying or otherwise, without
the express written permission from Marport. “Marport ”, the Marport logo and Software
Defined Sonar are registered trademarks of Marport. All other brands, products and
company names mentioned are the trademark and property of its respective owners only.
Marport is a division of Airmar Technology Corporation.
History
V1 10/02/17 First release
V2
V3
| 5

Catch Sensors | V1 | Introduction and Presentation
Introduction and Presentation
Tip: Click Marport logo at the bottom of pages to come back to the table of
contents.
Introduction
Marport's catch sensors tell you when your trawl starts to fill. Placed on the top of the
trawl codend, they monitor the amount of catch that you have and warn you when the
trawl is full. You can even use them to determine a precise amount of fish inside the
trawl net. This way, you can monitor the contents of the codend as you are fishing,
avoid problems of overfilling and increase fish survival rate inside the trawl net. It
is recommended to install several sensors along the trawl to better follow the filling
processes.
There are two types of catch sensors:
• Catch sensor: gives you the catch status of the trawl (empty or full), along with depth,
water temperature and pitch and roll information. Catch sensors can emit on a single
frequency of 40 kHz (Marport, Scanmar) or 70 kHz (Simrad, Wesmar), or on a dual
frequency (40 kHz/70 kHz).
• Catch Explorer: gives you the catch status of the trawl, with depth, water temperature
and pitch and roll information. In addition, it provides an echogram image of the
volume of catch inside the codend.
| 6

Catch Sensors | V1 | Introduction and Presentation
Applications
Here are some examples of data received from Catch Explorer and Catch sensors
displayed in Scala.
Catch Control System Installation
You can install several sensors on the codend to better follow the filling processes. It is
very useful to determine the amount of fish inside the trawl net: you can prevent damage
to fish and increase the security of crew and vessel.
For example, you can install three sensors on the codend. They will trigger one by one,
according to the amount of fish inside the codend. After a few tows, you can estimate the
amount of tonnage of fish that you have depending on whether one, two or three sensors
display a full status.
| 7

Catch Sensors | V1 | Introduction and Presentation
Catch Explorer display
When the codend is full, you cannot see the sea bottom anymore because fish may block
the signal.
| 8

Catch Sensors | V1 | Introduction and Presentation
Catch sensors display
Examples of 3 catch sensors with depth, pitch and roll.
| 9

Catch Sensors | V1 | Introduction and Presentation
Safety Guidelines
Important: To ensure proper and safe use of this equipment, carefully read and
follow the instructions in this manual.
Basic good practices
When using the product, be careful: mechanical shocks can cause damage to the
electronic components inside.
Never place the product in a hazardous and/or flammable atmosphere.
Product installation and use
Install and use this product in accordance with this user manual. Incorrect use of the
product may cause damage to the components or void the warranty.
Only qualified Marport dealers can do internal sensor maintenance and repairs.
Precautions
Warning: In case of water ingress in the product, do not charge it: battery may
vent or rupture, causing product or physical damage.
| 10
Otros manuales para Catch Sensor
1
Tabla de contenidos
Otros manuales de Accesorios de Marport



















