MABRU POWER SYSTEMS SC4.2 Manual de usuario

MARINE SELF-CONTAINED DIRECT
EXPANSION AIR CONDITIONING SYSTEMS
Installation Manual
· SC4.2 (Z)
· SC06 (Z)
· SC10 (Z)
· SC12 (Z)
· SC16 (Z)
· SC4.2 (Z) DC
· SC06 (Z) DC
· SC10 (Z) DC
· SC12 (Z) DC
· SC16 (Z) DC
Models :

Introduction
Safety Precautions
Safety Precautions
Technical Parameters
Outline Drawings
Installation Overview
Blower Rotation
Placement of A/C Unit
Ducting
Seawater System
Installation Checklist and Final Inspection
Operation Controls and Display Remote
Wiring Diagram
Troubling Shooting
2
3
4
6
10
11
12
13
14
15
16
17
19
22

hank you very much for purchasing our SC series marine self-contained
air conditioning unit!
Our company was determined to create an ISO9001 standard unit that
surpassed our customer’s expectations by using only the best components known
to outlast and out preform our vigorous quality standards.
Higher fl ow, and greater effi ciency, reliability and robustness:
• Super high effi ciency, quiet compressor and high velocity ball bearing fan.
• Elegant Vimar compatible multi color digital control display, including both
heat and cool settings.
• Auto speed fan complete with “quiet” low speed mode to ensure a restful sleep.
• Extra resilient CuNi condensing coils.
• Stainless steel chassis and drain pan combination.
We are so confi dent regarding the quality of our units that we are currently
the only manufacturer who provides a compressor lifetime warranty!

VERY IMPORTANT SAFETY CONSIDERATIONS
1- Never install your air conditioner in the bilge or engine room areas.
2- Ensure that the selected location is sealed from direct access to bilge
and/or engine room vapors.
3- Do NOT terminate condensate drain line within three feet of any
outlet of engine or generator’s exhaust systems, nor in an engine or
generator’s compartment housing, nor in a bilge, unless the drain is
connected properly to a sealed condensate or shower sump pump.
SAFETY WARNING
- The a/c unit should never be placed such that it can circulate carbon
monoxide, fuel vapors or other noxious fumes into the boat’s living
spaces.
- Do not install or operate a self-contained unit in the engine room or
near an internal combustion engine. Failure to follow this precaution
could result in serious injury or death.
IGNITION PROTECTION WARNING
- Self-Contained units do NOT meet federal requirements for ignition
protection, DO NOT install in spaces containing gasoline engines, tanks,
LPG/CPG cylinders, regulators, valves or fuel line fi ttings. Failure to
comply may result in injury or death.
- Installation and servicing of this system can be hazardous due to system
pressure and electrical components.
- When working on this equipment, always observe precautions
described in the literature, tags and labels attached to the unit.
- Follow all safety codes. Wear safety glasses and work gloves and place
a fi re extinguisher close to the work area.

PRIOR TO INSTALLATION, Please read these instructions completely
and then plan all connections which must be made to the a/c unit
including ducting, condensate drain line, seawater inlet and outlet
hoses, electrical power connection, location of control and seawater
pump placement, to assure easy access for routing and future servicing.
INSTALLATION OVERVIEW:
See Figure 1 for an overview of a typical SC a/c system installation.
BLOWER ROTATION
-Rotate the blower to the direction which allows the most direct airfl ow
discharge through the ducting.
-Loosen the adjustment screw on blower mount ring, rotate blower to
desired position, and then tighten adjustment screw (See Figure 2).
PLACEMENT OF A/C UNIT
IMPORTANT INSTALLATION NOTE: The condensate base pan is equipped
with vibration isolators installed in the bottom of the pan. These isolators
are designed to dampen the vibration caused by the operating A/C
unit from transferring into the mounted surface.
- Care must be taken when moving the a/c unit across mounting
surfaces as isolators can be damaged.
- Isolators will not normally pull out of pan, but can turn sideways if
dragged and may break if excessive dragging occurs.
- Unit must be picked up after moving to allow isolator to reset into well,
or vibration isolation will be ineffective.
-The a/c unit must be mounted to a low fl at level surface, in bottom of
locker, under a bunk or dinette seat or in a similar location.
Please read the safety considerations above and see Figure 1
before mounting unit.

TECHNICAL PARAMETER LIST 1 (110V / 60Hz / 1 UNIT, AC BLOWER)
Model No. SC4.2 (Z) SC06 (Z) SC10 (Z) SC12 (Z) SC16 (Z)
Cooling capacity Btu/h 4200 6000 10000 12000 16000
Heating capacity Btu/h 4500 6500 11000 13500 17600
Power source 110V/60HZ/1
Input power (kW) Cooling 0.34 0.53 0.81 1.05 1.20
Heating 0.47 0.69 1.09 1.30 1.59
Amp Draw (A) Cooling 2.9 4.7 7.1 9.2 10.8
Heating 4.2 6.0 9.3 11.5 13.9
Air fl ow(CFM) H/M/L 250/200/100 300/250/210 350/300/250 400/350/300 500/450/350
Refrigerant R134a R410a R410a R410a R410a
Minimum Air Duct size
in/(mm) 4/(101) 4/(101) 5/(127) 5/(127) 6/(152)
Minimum Return Air Grille
size sq in/(sq cm) 64/(413) 64/(413) 100/(645) 121/(780.5) 144/(929)
Minimum Supply Air Grille
size sq in/(sq cm) 16/(103) 20/(129) 20/(129) 25/(161) 36/(232)
Seawater pipe in (mm) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16)
Net Weight Ibs (kg) 29.4 (13.3) 42.5 (19.2) 51.8 (23.4) 55.7 (25.2) 67.4 (30.5)

Model No. SC4.2 (Z) SC06 (Z) SC10 (Z) SC12 (Z) SC16 (Z)
Cooling capacity Btu/h 4200 6000 10000 12000 16000
Heating capacity Btu/h 4500 6500 11000 13500 17600
Power source 220V/60HZ/1
Input power (kW) Cooling 0.35 0.54 0.81 1.08 1.21
Heating 0.48 0.70 1.10 1.32 1.61
Amp Draw (A) Cooling 1.5 2.4 3.5 4.6 5.6
Heating 2.2 3.0 4.8 5.8 7.0
Air fl ow(CFM) H/M/L 250/200/100 300/250/210 350/300/250 400/350/300 500/450/350
Refrigerant R134a R410a R410a R410a R410a
Minimum Air Duct size
in/(mm) 4/(101) 4/(101) 5/(127) 5/(127) 6/(152)
Minimum Return Air Grille
size sq in/(sq cm) 64/(413) 64/(413) 100/(645) 121/(780.5) 144/(929)
Minimum Supply Air Grille
size sq in/(sq cm) 16/(103) 20/(129) 20/(129) 25/(161) 36/(232)
Seawater pipe in (mm) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16)
Net Weight Ibs (kg) 29.4 (13.3) 42.5 (19.2) 51.8 (23.4) 55.7 (25.2) 67.4 (30.5)
Model No.
SC4.2 (Z)
SC06 (Z)
SC10 (Z)
SC12 (Z)
SC16 (Z)
TECHNICAL PARAMETER LIST 2 (220V / 60Hz / 1 UNIT, AC BLOWER)

TECHNICAL PARAMETER LIST 3 (110V / 60Hz / 1 UNIT, DC BLOWER)
Model No. SC4.2 (Z) SC06 (Z) SC10 (Z) SC12 (Z) SC16 (Z)
Cooling capacity Btu/h 4200 6000 10000 12000 16000
Heating capacity Btu/h 4500 6500 11000 13500 17600
Power source 110V/60HZ/1
Input power (kW) Cooling 0.32 0.51 0.78 1.01 1.17
Heating 0.45 0.66 1.05 1.28 1.56
Amp Draw (A) Cooling 2.8 4.5 6.8 8.8 10.5
Heating 4.1 5.8 9.1 11.2 13.5
Air fl ow(CFM) H/M/L 250/200/100 300/250/210 350/300/250 400/350/300 500/450/350
Refrigerant R134a R410a R410a R410a R410a
Minimum Air Duct size
in/(mm) 4/(101) 4/(101) 5/(127) 5/(127) 6/(152)
Minimum Return Air Grille
size sq in/(sq cm) 64/(413) 64/(413) 100/(645) 121/(780.5) 144/(929)
Minimum Supply Air Grille
size sq in/(sq cm) 16/(103) 20/(129) 20/(129) 25/(161) 36/(232)
Seawater pipe in (mm) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16)
Net Weight Ibs (kg) 29.4 (13.3) 42.5 (19.2) 51.8 (23.4) 55.7 (25.2) 67.4 (30.5)

TECHNICAL PARAMETER LIST 4 (220V / 60Hz / 1 UNIT, DC BLOWER)
Model No. SC4.2 (Z) SC06 (Z) SC10 (Z) SC12 (Z) SC16 (Z)
Cooling capacity Btu/h 4200 6000 10000 12000 16000
Heating capacity Btu/h 4500 6500 11000 13500 17600
Power source 220V/60HZ/1
Input power (kW) Cooling 0.32 0.51 0.78 1.01 1.17
Heating 0.45 0.66 1.05 1.28 1.56
Amp Draw (A) Cooling 1.4 2.3 3.4 4.4 5.3
Heating 2.1 2.9 4.6 5.6 6.8
Air fl ow(CFM) H/M/L 250/200/100 300/250/210 350/300/250 400/350/300 500/450/350
Refrigerant R134a R410a R410a R410a R410a
Minimum Air Duct size
in/(mm) 4/(101) 4/(101) 5/(127) 5/(127) 6/(152)
Minimum Return Air Grille
size sq in/(sq cm) 64/(413) 64/(413) 100/(645) 121/(780.5) 144/(929)
Minimum Supply Air Grille
size sq in/(sq cm) 16/(103) 20/(129) 20/(129) 25/(161) 36/(232)
Seawater pipe in (mm) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16) 5/8 (16)
Net Weight Ibs (kg) 29.4 (13.3) 42.5 (19.2) 51.8 (23.4) 55.7 (25.2) 67.4 (30.5)

Model No. W (in/mm) D (in/mm) H (in/mm)
4200BTU Model
SC4.2/SC4.2Z/SC4.2DC/SC4.2ZDC 13.8/330.5 7.5/190.5 9.4/238
6000BTU Model
SC06/SC06Z/SC06DC/SC06ZDC 15.6/396 9.4/239 11/279.4
10000BTU Model
SC10/SC10Z/SC10DC/SC10ZDC 18.9/480 11.2/284 11.6/294.6
12000BTU Model
SC12/SC12Z/SC12DC/SC12ZDC 18.9/480 11.2/284 11.6/294.6
16000BTU Model
SC16/SC16Z/SC16DC/SC16ZDC 19.5/495 12.4/315 12.9/327.6