Luminor BLACKCOMB Manual de usuario

Operaon & Installaon Instrucons
EQUIPMENT MODULES
BL
ACKCOMB
OWNER’S MANUAL
illuminating technologies for life

Table of Contents
Emulator Module .............................................. 1
Remote Alarm Module ...................................... 2
4-20 mA Module................................................ 3
Solonoid Module ............................................... 4
SHERPA Water Quality Monitor Module ........... 8
UV Concierge Module ..................................... 10
*Modules not available in all markets.
*TheseinstruconsareavailableinsocopyviaemailfromLuminorCustomerService.
CAUTION: The appliance is not to be used by persons (including children) with reduced
physical, sensory or mental capabilies, or lack of experience and knowledge, unless they
have been given supervision or instrucon.
Children should be supervised so that they do not play with the appliance.

1|Page
EMULATOR MODULE
MODEL # MOD-EMU
The Emulator module comes with a male
IEPconnecon(InniteExpandability
Port).Priortostart-up,rstensureallthe
toggleswitchesforthe“ModuleAlarms”
and“LampAlarm”areintheOFF(toggle
up)posion.PlugtheEmulatorconnector
intotheIEPontheBLACKCOMB/HO
controller,thenpluginthecontroller
powercord.
ToEmulateaparcularmodulefailure,
togglethecorrespondingswitchtothe
ON(toggledown)posion.Thealarm
can be cleared by returning the switch to
itsOFF(toggleup)posion.Thedevice
alsocanemulatetheUVintensityreportedbyaUVsensormodule.Turningtheright“UV”
knobintheclockwisedireconwillincreasetheintensity,whileturningitcounterclockwisewill
decreasetheintensity.Pleasenotethattoseeallthecapabiliesofthesensor,youwillneed
tocycletheintensitythroughtherangeof49through66%.The“DaysRemaining”cyclecan
alsobeadjustedbyturningthele“Days”knob.Theemulatormodulemustonlybesupplied
atSELV.
*Fordealeruseonly.Notavailableforsaletogeneralpublic.
Emulation Module
Module Alarms
Closed Open
Days UV
Sensor Solenoid 4-20 LampRemote Alarm
Solenoid Status
MOD-EMU
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon

2|Page
REMOTE ALARM MODULE
MODEL # MOD-RAM
TheRemoteAlarmmodulecomeswithbothamaleandfemale
IEPconnecon(InniteExpandabilityPort).Toiniatethemodule
simplyplugthemaleplugintotheIEPontheStandardorHigh
Outputcontroller,orintoanyotherBLACKCOMBmodulethat
containsanIEP(sensor,4-20mAmodule,solenoidmodule,etc.)
and then restart the system.
TheRemoteAlarmmoduleisapairofdrycontactsandcanbe
usedtoconnectthecontrollertoaPLCbasedsystem,analarm
buzzer(orlight),oran“OK”light.Maximumcontactrangis30V
/1A.Iftheconnecteddevice(eg.lightorbuzzer)exceedsthe1A
currentrangthenusetheRemoteAlarmModuletocontrolan
appropriatelyratedrelay.
TheremotealarmmodulemustonlybesuppliedatSELV.
Disconnectpowersupplybeforeservicing.
“OK”
Light
Customer
Power Supply
Maximum 30V
“FAIL” Light/Buzzer
Autodialer
Customer
Power Supply
Maximum 30V
Sensor IEP
Installaon
IEP
connecon
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon
Figure 1
Secure module to
wall with screws
Figure 2
IEPconnecon
IEP

3|Page
4-20 mA MODULE
MODEL # MOD-420
The4-20mAmodulecomeswithbothamaleandfemaleIEP
connecon(InniteExpandabilityPort).Toiniatethemodule
simplyplugthemaleplugintotheIEPonthecontroller,orinto
anyotherBLACKCOMBmodulethatcontainsanIEP(sensor,
remotealarm,solenoidmodule,etc.)
The4-20mAmodulemustonlybesuppliedatSELV.Disconnect
powersupplybeforeservicing.
Connect “LOOP” Connecons as follows:
Sensor IEP
Installaon
IEP
connecon
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon
Figure 1
Secure module to
wall with screws
Figure 2
IEPconnecon
IEP
LOOP Specifications
Power Supply: Min 5 volts
Max 30 volts
Power Supply
PLC
or
Data Logger
Power Supply (must be SELV):
Min 5 volts
Max 30 volts

4|Page
SOLENOID MODULE
MODEL # MOD-SOL1 (in 110V, NEMA 5-15 plug)
MOD-SOL2 (in 230V, CEE 7/7 plug)
MOD-SOL3 (in 230V, BS 1363 plug)
MOD-SOL4 (in 230V, AS/NZS 3112 plug)
TheSolenoidModuleisdesignedtoconnectaNORMALLY
CLOSEDlinevoltagesolenoidvalvetothecontroller.Itis
possibletousea12Vor24Vnormallyclosedsolenoidby
replacingtheACpowercord.Notethatthemaximumcontact
rangis240VAC(50-60Hz)/30VDC/2A.
LOCATION
Step 1) Findasuitablelocaononthewallforthesolenoid
module. The module must be installed close enough to the
controller,ortheUVsensortobeabletopluginthemale
IEP connector. The module must also be installed close
enough to the actual solenoid valve and this distance will
bedependentonthecordlengthoftheparcularsolenoid
valve that is used.
Step 2)Pickalocaonforthesolenoidvalveandinstallas
perthemanufacturer’sdirecons.Thesolenoidmodule
requiresbareleadsforconnecontoterminalblocks,so
ifthesolenoidcablehasaplugaached,removetheplug
andstripthewirestoasuitablelength.
INSTALLATION
Step 1) MakesurethesolenoidvalvecableisNOTpluggedintotheelectricaloutlet.Insert
thesolenoidvalvecablethroughthecenterholeofthemiddlestrainrelief.Connectthethree
electricalwirestotheterminalblockthatismarked“SOLENOID”(seeFig.2).Connectthe
groundwireintheposionmarked“GND”,thelinevoltagewireintheposionmarked“L1”
andtheneutralwireintheposionmarked“N”.Typicalwirecolourconguraonsaremarked
directlyonthecircuitboardtotheleoftheSOLENOIDterminalblocktoaidinthisprocess
(seeFig.3)Ifyouareunsureofthecorrectwiringconguraonforyouparcularsolenoid
valve,pleasecontactanapprovedelectricalcontractor.Onceallthelinevoltageconnecons
havebeenmade,ghtenthestrainreliefnuttosecurethecabletothesolenoidmodule.
Figure 3
WiringColourGuide
Figure 2
SolenoidWireInstallaon
Figure 1
Secure
module to
wall with
screws

5|Page
Step 2) Plugthesolenoidvalveintotheapplicableelectrical
outlet.Atthisstage,thefunconalityofthesolenoidvalve
canbetestedbypressingthesolenoidtestbuonlocatedon
theupperleofthecircuitboard.Manuallydepressing(and
holding)thisbuonwillcompletetheelectricalcircuitandwill
openthenormallyclosedsolenoidvalve.Youshouldbeableto
heartheacvaonofthesolenoidvalveatthisstagetoensure
thevalveisfunconingproperly(seeFig.4).
Step 3) MakesureyourUVcontrollerisunpluggedfromthe
powersource.Oncealltheseconneconshavebeenmade,
axthemaleIEPplugofthesolenoidmodulecableintothe
IEPportonthecontroller(seeFig.5),oranyotheravailable
IEPportsuchastheUVsensor,4-20mAmoduleorremote
alarmmodule.ItdoesnotmaerwhichIEPportanymodule
isaachedto,aslongastheyareaached.
OPERATION
Step 1) PlugtheBLACKCOMBcontrollerintothepower
sourceandmakesurethesolenoidmoduleisacvatedon
thecontroller.Duringthestart-upsequence,theSOLENOID
MODULEscreenwillindicatea“inialized”whenthemodule
isacvatedproperly(seeFig.6).
Figure 4
SolenoidTestBuon
Figure 6
Solenoid
Acvaon
Screens
Sensor IEP
Installaon
IEP
connecon
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon
Figure 5
IEPconnecon
IEP

6|Page
Step 2) Thecontrollerwillonlynofyyouwhenthereisafailure
modewherebythesolenoidmodule(andconnectedsolenoidvalve)
willbeacvated.OntheBLACKCOMB5.1system,thesolenoid
modulewillbeacvated(shungotheowofwater)uponLAMP
FAILURE(seeFig.7).Toremedythis,replacetheUVlampandrestart
thesystemasperthedireconsoutlinedintheOwner’sManual.
Step 3) OntheBLACKCOMB6.1systemwhereaUVsensorisinstalled,
thesolenoidmodulewillbeacvated(shungotheowofwater)
uponaLOWUVcondion(lessthan50%)(seeFig.8).Toremedythis,
youwillneedtoaddressthereasonforthislowUVcondionwhich
may be due to a dirty UV sensor and quartz sleeve, a lamp that is
not eming enough UV energy, or a change in the water quality.
PleaserefertotheUVsystemsOwner’sManualforcorrecveacon
procedures.
Figure 7
LAMPFAILUREScreen
Step 4) To determine what posion the solenoid valve is currently in, the solenoid module
incorporates three lights on the circuit board (see Fig. 9). When the solenoid is in the OPEN
posionagreenlightwillappearonthecircuitboardbesidetheword“OPEN”.Whenthevalve
isCLOSED,aredlightwillappearonthecircuitboardbesidetheword“CLOSED”.Andwhenthe
solenoidisinanOVERRIDEposion,anamberlightwillappearonthecircuitboardbesidethe
word“OVERRIDEON”.
Figure 8
LOWUV
Screens
Figure 9
Solenoid Status
(Colour)
Boil Water Advisory: If any failure occurs on a BLACKCOMB UV system, the water
must not be used for human consumpon unl the system is returned to a safe operaonal
mode. If the water is used for human consumpon during this period, the water must be
boiled (minimum 20 minutes at a full boil) prior to consumpon.
EMERGENCY BYPASS
Inacasewherethesolenoidvalvehasbeenacvated(valveisclosedandnowaterisallowed
toow),thesolenoidmodulehastheabilitytobypassthesolenoidvalveincaseofan
emergencyneedofwater.Toiniatethisbypass,depressthebuonlabeled“OVERRIDE”
locatedinthelowerleporonofthecircuitboard(seeFig.10)

7|Page
Figure 10
SolenoidBypass
Buon
Oncethisbuonhasbeenpressed,thesystemwillremaininthis
overridemoderegardlessofwhetherornotthecondioncausingthe
solenoidacvaonhasbeenremediedornot.Toresetthesystem,
thepowertothecontrollermustbeshutoandrestarted.While
inthisoverridemodethecontrollerwillintermientlydisplayared
“SOLENOIDOVERRIDE”screen(seeFig.11).
Figure 11
SOLENOIDOVERRIDE
Screen
DISABLING EMERGENCY BYPASS
Incertainregulatedapplicaons,theavailability,anduse,
oftheemergencybypassfeaturemaybeinviolaonofthe
local,state/provincialcodes.Ifthisisthecase,thebypass
featurecaneasilybedisabledbyphysicallyremovingthe
bypassbuon.Toaccomplishthis,carefullyuseapairof
needlenosepliersandphysicallyremovetheactualbypass
buon(marked“OVERRIDE”)fromthecircuitboard.
Figure 12
SOLENOIDFAILURE
Screen
OTHER FAILURE MODES
Intheeventthereisanissuewiththesolenoidconneconfrom
theIEPcabletothecontroller,thesystemwillregistera“SOLENOID
FAILURE”screenonthecontroller(seeFig.12).
CAUTION: BEFORE PERFORMING ANY
WORK ON THE SOLENOID MODULE, THE
POWER CORD MUST BE DISCONNECTED
FROM ITS POWER SOURCE (WALL PLUG).

8|Page
WATER QUALITY
MONITOR MODULE
MODEL # MOD-SHERPA
ThemodulecomeswithaSHERPATransmierandaSHERPARemoteDisplay.TheTransmier
connectstoaBLACKCOMBandBLACKCOMB-HOcontrollerandtransmitsthecontroller’sstatus
wirelesslytotheRemoteDisplay.EveryTransmierandRemoteDisplayispairedtogether
andusesencryptiontocreateareliableandsecurecommunicationlinkbetweenthetwo
devices.EveryTransmiersupportsuptoveRemoteDisplays.AdditionalRemoteDisplays
canbepurchasedandinstalledseparately.Referto‘PairinganAdditionalRemoteDisplay’for
additionalRemoteDisplayinstallation.
Sensor IEP
Installaon
IEP
connecon
BLACKCOMB
Controller
BLACKCOMB-HO
Controller
IEP
connecon
IEP
connecon
Installation
Step 1)PowerotheBLACKCOMBorBLACKCOMB-HOcontroller.
Step 2)PlugthemaleplugoftheSHERPATransmierintotheIEP(InniteExpandability
Port)onthecontroller,orintoanyotherLUMINORmodulethatcontainsanIEP
(sensor,4-20mAmodule,solenoidmodule,etc.)andthenrestartthesystemNote1.
Step 3)ToReceivetheBLACKCOMBor
BLACKCOMB-HOcontroller’s
status on the SHERPA Remote
Display,plugtheAC/DCwall
adapterintothePowerPorton
theSHERPARemoteDisplay(5V
Max)andslidetheswitchto
theONposion.
Back of
Remote
Display
SHERPA Transmier
SHERPA Remote Display
50m/164
(Note2)