1. Introduction
3.1 General product information
3.2 Technical Specifications
3.4 Spectrum Graph
3.5 Light distribution curve
3.6 Environment
3.7 Legal
6.1 Assemble the frame
6.2 Connect the driver
6.3 Connect the LED light bars
6.4 Replacing and changing light bars
6.5 Installing the fixture
6.6 Connecting the manual dimmer control
6.7 Connecting fixtures in series for external control
6.8 Connecting the LED fixture to the mains
2. Product Description
3. Product information and specifications
4. Safety recommendations and warnings
5. Contents
7. Precautions when using the LED fixture
8. Inspection, maintenance and repair
9. Storage and disposal
10. Warranty
6. Instalation
TABLE OF CONTENTS
3.3 Fixture Dimensions

1. INTRODUCTION
Thank you for purchasing the Lumatek Zeus 600W linear multi-light bar LED fixture. This manual describes how to
install and use the Zeus fixture; please read this manual thoroughly before attempting to install or operate any
Lumatek Zeus Series system. If you are not comfortable with the installation of high performance lighting
systems, you should seek the services of a qualified installation professional.
The Lumatek Zeus 600W LED is an electronic horticultural LED fixture using a linear array design with six LED light
bars. The Zeus is a high performance full-cycle top lighting solution for commercial horticulture cultivation, with
the power and flexibility to scale from vegetative growth to higher light intensities in bloom.
In this manual the Lumatek Zeus 600W LED will be referred to as: “the LED fixture”.
2. PRODUCT DESCRIPTION
3. PRODUCT INFORMATION AND SPECIFICATIONS
3.1 General Product Information
PRODUCT NAME
PRODUCT CODE
PRODUCER
Lumatek Zeus 600W LED
LUMLED001
Lumatek EU
5060560030713
UK/EU
EAN
PLUG TYPE
3.2 Technical Specifications
LIFE SPAN
INPUT POWER
INPUT CURRENT 230V , 100% o/p
PPF
WORKING TEMPERATURE
WORKING HUMIDITY
INPUT VOLTAGE
POWER FACTOR
SPECTRUM
EFFICACY
LIGHT SOURCE
DIMENSIONS (LxWxH)
WEIGHT
BEAM ANGLE
MANUAL DIM/EXTERNAL
LIGHTING CONTROLLER
WATERPROOF
600W
195 -240V 50/60Hz
Fullspectrum
1380 μmol/s
2.3 μmol/J
>0.95
2.61A (3.2A max)
LUMILED (W)& Osram (R) LED
1182 x 1091 x 75mm
13.5Kg
>50000H
-20º -- +40ºC
20% - 90%
IP65
120º
0-10V analog protocol

1181.2mm
1091mm 51.9mm
74.2mm
3.3 Fixture Dimensions
3.4 Spectrum Graph
1.2
1.0
0.8
0.6
0.4
0.2
0.0
350 463 575 688 800
wavelength (nm)
Full Spectrum

Unit: cd
C0/180 , 117.3
C30/210 , 117.6
C60/240 , 115.9
C90/270 , 114.2
3.5 Light distribution curve
3.6 Environment
The LED fixture is intended to be used in climate-controlled grow rooms, indoor farms and greenhouses.
The product may be used in damp environments but may not be used in wet environments or outdoors.
The product will operate in ambient temperatures from -20ºC to 40ºC but will function at optimal level
between 20ºC to 30ºC.
The product will operate in 20% – 90% humidity, non-condensing.
3.7 Legal
This product is CE certified compliant with LVD and EMC directive test standards.
LVD;
EN 60598-1:2015+A1:2018
EN 60598-2-1:1989
EN 62031:2008+1:2013+A2:2015
EN 62493:2015
EMC;
EN 55015:2013+A1:2015
EN 61547:2009
EN 61000-3-2:2014
EN 61000-3-3:2013
Warning! Carefully read the warnings below before using or working with the product!
• Always adhere to the local rules and regulations when installing or using the LED fixture.
• Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying
the LED fixture can be dangerous and will void the warranty.
• Do not use the LED fixture when either the LED fixture or its power cable are damaged. Replace the power
cable with correctly rated cable only.
• Modifications to the cables can lead to unwanted electromagnetic effects which may make the product
not comply with legal requirements.
• Do not expose the LED fixture to:
Condensing humidity, heavy mist or direct spray;
Ambient temperatures outside the specified range;
Dust and contamination;
Direct sunlight during use or HID light that may heat up the driver.
4. SAFETY RECOMMENDATIONS AND WARNINGS

• Always disconnect the LED fixture from mains before performing any maintenance.
• Always allow for a cool down period of at least 20-30 minutes before touching the LED light bars. Touching
the LED bars when the fixture is lit or immediately after may result in burns!
• Natural convection removes heat away from the heatsink. In order for the system too properly cool itself,
at least 5cm of space is required between the fixture and the roof of your grow area. Do not use abrasive
materials or aggressive cleaning agents to clean the LED fixture as this may damage
the secondary optics. Instead use a clean dry fabric/cloth.
• Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach
temperatures of 40ºC.
• Do not use sulphur vaporizers or water misters.
• The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can
lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result
of incorrect installation and use revokes the warranty.
Warning! Mounting and installing the LED fixture must be in accordance with the applicable local laws and
regulations.
Warning! The installer is responsible for correct and safe installation.
Warning! Ensure the local cabling can support the voltage and current requirements of the LED fixture.
Warning! Avoid coiled cables and keep mains leads separated to help prevent electromagnetic interference.
Warning! Do not connect or disconnect the LED fixture under load.
5. CONTENTS
6. INSTALLATION
1x LED FRAME B
Contains power input cables
(female connectors)
6x LED LIGHT BAR
1x LED DRIVER
Power output cables
(male connectors)
to face Frame B
1x SUPPORT FRAME
Contains driver tray
1x LED FRAME A
1x DIMMING
CONTROLLER 0 -10V
Connects to dimming control
cable on driver.
1x MANUAL
2x METAL CABLE HANGERS

6.1 Assemble the frame
6.2 Connect the driver
Note the direction when installing; the driver tray is on top when the fixture is hung.
Press button on the frame push-click connector to connect and ensure button pops up in hole socket to lock.
Note the direction when installing; the driver tray is on top when the fixture is hung.
Connect Frame A and B to
the support frame by
pressing button on frame
connector and inserting
into support frame socket
and lock.
Connect Frame B to
support frame end near
support plate.
Press button on Frame A
push-click connector to
connect to support frame
and ensure button clicks
into hole socket to lock.
Place the driver in the tray and secure by
fastening screws in end plates.
Connect driver output power cables
to LED fixture power input cables.

Ensure the driver is secured and flip the fixture over
so the driver is now underneath. Insert the end
of the light bar with the hook into the square
hole in Frame A
Then insert the other end; align the round hole
on Frame B with the light bar’s magnetic end
and insert male pin into female socket.
Ensure magnetic connection is secure.
6.3 Connect the LED light bars
6.4 Replacing and changing light bars
Assemble the rest of the light bars into the fixture frame as shown in the figure above.
Attach metal cable hangers
to mounting hooks
6.5 Installing the fixture
Warning! Mount the system to something that can hold the weight of the LED fixture.
Ensure all light bars are installed correctly and are secure. Carefully turn the fixture over and attach the
metal cable hangers to the mounting hooks. Hang the fixture in required position and height. For optimal
performance; position fixture 50cm above plant canopy. Ensure the fixture is hung horizontally.
Individual 100W light bars are available to purchase as replacements or with different spectral ratios to adjust
fixture spectral output.
The Zeus fixture’s modular design has an intelligent LED driver which can autosense and decrease or increase
power to match the amount of 100W light bars installed on the fixture.
Warning! At least one light bar must be installed in the fixture before switching on.

6.6 Connecting the manual dimmer control
The dimmer control is connected to the dimmer wire from the driver. This enables light intensity (PPF output)
to be adjusted according to requirement. The LED fixture light intensity can be adjusted without changing
spectral power distribution or losing efficiency.
6.7 Connecting fixtures in series for external control
For detailed instructions please refer to the Lumatek Control Panel manual.
Position and hang each fixture appropriately. Connect the signal wire T-junction component to
the fixture 1 dimmer wire.
Connect dimmer cable to
manual dimmer control or
Lumatek digital lighting
controller or series connection
to other fixtures for external
control.
Connect controller output signal wire to
fixture 1 T-junction input. Connect signal wire
from fixture 1 T-junction output to fixture 2
T-junction input. Continue to connect fixtures
in series for up to 100 fixtures per controller
see Figure below.

6.8 Connecting the LED fixture to the mains
Warning! Make sure mains power is switched off.
Warning! Ensure the power supply cable is not coiled and does not touch any hot surfaces.
Warning! Connect the cables according to local rules, safety regulations and electrical code.
Warning! Ensure external switching gear can cope with the inrush current of the LED fixture. Always use a
double pole contactor suitable for switching a capacitive load. Never use household timers to switch the LED
fixture! Connect to switching gear/power supply. Switch on mains power.
Warning! Do not connect or disconnect the LED fixture under load.
Warning! Always ensure at least one light bar is connected to the fixture before switching on.
The Zeus has an intelligent LED driver which will increase or decrease power to match the amount of light bars
connected to the system.
Warning! Always wait 20 – 30 minutes for the LED light bars to cool down.
Warning! Disconnect the LED fixture from mains before performing any maintenance or repairs.
Warning! Do not connect or disconnect the LED fixture under load.
Warning! Do not open or disassemble the LED fixture, it contains no serviceable parts inside. Opening the LED
fixture can be dangerous and will void the warranty.
Warning! Always wait 20 – 30 minutes for the LED light bars to cool down.
Caution! Do not clean the LED fixture with detergents, abrasives or other aggressive substances.
Regularly check the LED fixture for dust or dirt build up. Clean if necessary. Contamination may cause
overheating and decreased performance.
Clean the outside of the LED fixture using a dry or damp cloth.
Regularly check the cables of the LED fixture to ensure it is undamaged.
7. PRECAUTIONS WHEN USING THE LED FIXTURE
9. STORAGE AND DISPOSAL
8. INSPECTION, MAINTENANCE AND REPAIR
Store the LED fixture in a dry and clean environment, with an ambient temperature of -25ºC to 55ºC.
The product must not be discarded as unsorted municipal waste but must be collected separately for the
purpose of treatment, recovery and environmentally sound disposal.
10. WARRANTY
Lumatek Ltd warrants the mechanical and electronic components of their product to be free of defects in
material and workmanship if used under normal operating conditions for a period of five (5) years from the
original date of purchase. If the product shows any defects within this period and that defect is not due to user
error or improper use Lumatek Ltd shall, at its discretion, either replace or repair the product using suitable new
or reconditioned products or parts. In case Lumatek Ltd decides to replace the entire product, this limited
warranty shall apply to the replacement product for the remaining initial warranty period, i.e. five (5) years
from the date of purchase of the original product. For service; return the product to your shop with the original
sales receipt.
For more information on Lumatek products
visit www.lumatek-lighting.com
Otros manuales para ZEUS 600W
1
Tabla de contenidos
Idiomas: