Look Solutions VIPER DELUXE Manual de usuario

1
a Look Solutions product
Operating manual
viper
deluxe

2
Set of Equipment supplied
– 1Viper 2.6deLuxe (3050W) or Viper NT deLuxe (1750W)
– 1powerCONTRUE1TOPcable
– 1tanklidwithquickconnector,silicontubeandairvalvelter
– 1Operatingmanual
Pleasecheckwhetheralltheproductsyouorderedaresupplied.
Originaloperatingmanual,version01/2022
Pleasenote:Dependingontheinstalleddevice,wattandvoltspecicationswillchange.
The device cannot be operated from 110 V - 240 V.ThedeLuxeisdeliveredinthe
230Vversion.
If110Voperationisplanned,a110VViperNTandanappropriatetransformerforthefan
mustbeinstalled.TheViper2.6isnotsuitablefor110Voperation.

3
Content
1. Introduction 4
2. Safety instructions 5
3. Description of the parts 6
4. Fluid 8
4.1GeneralNotes
4.2Rellingtheuidcontainer
5. Operating the Viper deLuxe9
5.1Selectingthelocation 9
5.2Puttingintooperation 9
5.3Switchingthedeviceo 10
5.4ControlviaDMX512 10
5.4.1AdjustingtheDMXstartaddress
5.4.2RDM
5.5Standalonemode 11
5.6Wiringofthesockets 11
6. Cleaning, Care and Maintenance12
7. Troubleshooting 13
8. Specications 14
9. Warranty Conditions 15

4
1. Introduction
TheViper deLuxeisthetouringversionoftheViper2.6resp.ViperNT.
Builtintoarobustightcasewithapowerfulfan,theViper deLuxeisreadyforanyuse.
Newfeaturesmakeiteveneasiertouse-placingandfoggingwithoutwastingalotof
timesettingandpreparing.
Thenew20Lattankcanbelledconvenientlyandeasily,guaranteeingalongerope-
ratingtime.
Thecastordishesallowforeasyandsafestackingandstowingoftheequipment.
Theperformanceofthemachineallowsapplicationsfromsmallclubstolargehalls,festivals
andevents,aswellasuseforairoworleaktestinginlargebuildings.
Theintendeduseofthedeviceistocreatearticialfog.

5
2. Safety instructions
• Veryhotsteamescapesfromthenozzle.Dangerofgettingburnt.
• Occasionallyveryhotdropletsofuidmayescapewheninoperation.Thusneveraimat
personsdirectlyandkeepaminimumdistanceof3mtothenozzle.
• Nevertouchthenozzlewheninoperation.Dangerofgettingburnt.
• Thelocationforthemachinemustbenon-ammable,non-combustibleandnotsensitive
toheat.Ithastobetwiceasbigasthemachine.
• Keepaminimumdistanceof60cmtoallammable,combustibleobjectsandobjects
sensitivetoheat.
• Glycolisalcoholandburnswithaslightlybluish,almostinvisibleame.Neverpointthe
fogatstrongsourcesofignitionlikereorpyrotechniceects.
• Neveropenthemachineandleavethemachineunattendedwhenconnectedtoapower
supply.
• Itisonlyallowedtoy/hangthemachinebyusingtheoriginalhangingset.
• Thevisibilityhastobemorethan2minroomswherepeoplewalkaround.
• Donotswallowthefoguid.Keepitawayfromchildren.Incaseofeyecontact,rinse
withalotofwater.Consultadoctorshouldyouhaveaccidentallyswallowedsomeuid.
• Spilleduidorsplasheduiddropletscancausesliphazard.Mopuptheuidanddispose
ofitaccordingtoregulations.
• Fogmayactivatesmokedetectors.
Articially-madefogcanbeproducedinmanydierentways.Themethodusedhereto
producefog,withadevicewhichworksaccordingtothevaporizerprinciple,isthemost
harmlessone.
Nocasehassofarbeenreportedinwhichasoundhumanbeinghasbeenharmedbecause
ofusingourdevicetoproducearticialfog.However,thiscanonlybeguaranteedifthe
professionalfoggeneratorsareusedaccordingly,i.e.atthecorrectvaporizationtemperatures
aswellaswiththecorrectlymixedfoguid.
We,however,recommend:People with health problems or problems of the respiratory
tract or with an inclination for allergies should avoid any contact with articially-made fog.
A fog machine is not a toy!

6
3. Description of the parts
Rear view
Front view
1:Fognozzle
2:Diverter
3:Fangrilleandfan
4:Carryinghandles
5:Filter
6:Castordishes
7:Automaticwheels
1
2
3
4
5
6
7
Control-Box
Connectorsfromlefttoright:
•DMX in (5pin)
•DMX out (5pin)
•Power in: ConnectorforpowerCONTRUE1TOP-cable
•Power out: 1xforfogmachineand1xforfan(alreadyconnectedwhensupplied)
•Analog out (Fog): Fogmachine(alreadyconnectedwhensupplied)
•Analog out (Fan): Fan(alreadyconnectedwhensupplied)
XXX= address · PXX = pump · FXX = fan
dmxin
active
power in
in out
dmx 512 power out power out analog out
(FOG)
analog out
(FAN)
~ ~
i
~
2.0
viper de luxe
Look Solutions

7
3. Description of the parts
12
14
13
15
Tank lid
Plasticspigot
Quickcoupling
Tanklid
Filter
12:
13:
14:
15:
8:Control-Box
9:Cableoutlet
10:20L-Fluidtank
11:Velcrotapeto
securethetank
Rear view
8
9
10
11

8
4. Fluid
4.2 Relling the uid tank
– Disconnectthetanklidbypressingthespringsinthengerrecessesinwardsandliftout
thecover.
– Disconnecttheuidtubefromthelidbypressingthequickcoupling[13]andremoving
theplasticspigot[12].
– LoosentheVelcroandtiltthecanisterabout45degrees.
– Torell,unscrewthelargebluecapfromthecanisterandllthetankwithuid.
– TiltthecanisterbackinanuprightpositionandtightenitwiththeVelcrostrap.
– Pushtheplasticspigot[12]intothequickcoupling[13],untilyouhearaclick.Thespigot
isnowlockedrmly.
4.1 General notes
Beforerellingtheuidcanister,makesurethattherearenoimpuritiesinsidethetank.
Ifnecessary,thecanistermustberinsedout.Thiswillpreventcloggingoftheheater.
TheViper deLuxe hasbeendesignedtobeusedwithoriginalLookfoguids.
ThefollowingLookfoguidsareavailable:
Quick-Fog thick,quickdisappearingfoguid
Regular-Fog thick,longlastingfoguid
Slow-Fog thick,extremelylonglastingfoguid
IfuidshavebeenusedotherthanLookfoguidswecan‘tgrantwarranty.
PLEASE NOTE:Thevaporizerofourmachines does not havetobecleaned!Cleaners,
availableonthemarket,candamagethevaporizer!Wecannotgrantwarrantyinthiscase.

9
5. Operating the Viper deLuxe
5.2 Putting into operation
Removethefrontcasecover.Therearcovercanremainonthecase.Simplyreleasethe
upperpartbypressingthespringsinthengerrecessesinwardandfoldingthecoverdown.
Thecontrolboxcanthenbeoperatedwithoutanyproblems.Theconnectionsforthefog
generatorandfanarealreadyconnectedtothecontrolbox.
XXX= address · PXX = pump · FXX = fan
dmxin
active
Upbutton
Downbutton
Pleasenote:TheModebuttonisnotsuitablefor„scrolling“throughthemenu.Itmustbe
pressedbrieyoneatatime.
EnterbuttonModebutton
Active-LED
DMX-LED
a. ConnectthesuppliedpowerCONTRUE1TOPcabletothe„Powerin“connectoronthe
operatingboxandinsertthe mains plugintoan earthed socket. Makesurethat the
correctoperatingvoltage(230V/50Hz)isavailable.
InthedisplayofthecontrolboxappearseitherthelaststoredDMXaddress(ifthedevice
isconnectedviaDMX)oraPandtwonumbers(seegureabove).
5.1 Selecting the location
ThelocationinwhichtheViper deLuxeisoperatedshould
– bedry,
– befreefromdustyorpollutedair,
– befreefromvibrations,
– beannon-ammableplaceorsurface,
– bewell-ventilatedwithfog-freeairkeepingtheambientoperatingtemperaturebetween
5°Cand45°Candtherelativeairhumiditybelow80%.

10
5. Operating the Viper deLuxe
5.3 Switching the device o
a. PresstheModebuttonuntil„OFF”appearsonthedisplay.After15secondsthemachine
willswitchoautomatically.Ontherightbottomedgeofthedisplayareddotwillappear,
indicatingthatthemachineisnotheatinganymore.
Youcanalsoswitchothemachinewithinthese15secondsbypressingthe
Enterbutton.
b. IftheDMXsignalislost,thedevicewillbeswitchedoautomaticallyafter15seconds
forsafetyreasons.
.
5.4 Operating via DMX 512
ConnecttheViper deLuxetoaDMX-deskusingthe5pin-XLRsocket„DMXin“ofthecon-
trolbox.AssoonasthemachinereceivesacorrectDMXsignal,theyellowDMX-LEDshines.
Nowthepumpandthefancanbeadjustedviathelightingconsole.
Please note:
TheViper deLuxe usestwochannelsatthedesk!Channel 1 = Pump, Channel 2 = Fan.
a)PresstheModebuttononthecontrolpanel,untilthreeguresappearontheLEDdisplay.
b) AdjusttherequestedstartaddressbypressingtheUp/Downbuttons.
5.4.1 Adjusting the DMX start address
b. Afteraheatingtimeofapprox.sevenminutes(ViperNT)orapprox.12minutes(Viper
2.6),thedeviceisreadyforoperation.
c. PresstheModebuttonuntilaPandtwoguresappearinthedisplay.Setthedesired
pumpvalueusingtheUp/Downbuttons.
d. PresstheModebuttonuntilanFandtwoguresappearinthedisplay.Setthedesired
fanvaluehere.
e. PresstheEnterbuttontostarttheunit.Thegreen„Active“LEDlightsup.