LockMaster LKM700 Manual de usuario

1
7000INST Copyright Lockmasters, Inc. 5/25/11
LKM7000
INSTALLATION INSTRUCTIONS
In A Single Motion, We’ll Change The Way
You Think About Security.
Increased Safety, Increased Security, Increased Functionality.
90 minute re rating alone or
with Kaba Mas X09.
Not rated when used with a
S&G 2740 lock. National Stock Number 5340-01-501-2828 US Patent #7,007,524,B2

2 7000INST Copyright Lockmasters, Inc. 5/25/11
LKM7000 EXPLODED VIEW
LOCKBODY AND PARTS
Component Part No.
Inside Base Plate Complete w/ Screws & Hardware 700013WBA
Internal Access Control 700016
Handle Tube 700013S01
Extended Spindle Kit 700013S01EXT
Complete Wiring Harness 700013S45
Yoke 700013S09
Bolt Spring 700013S18
Slide Spring 700013S46
Trigger Spring 700013S19
LKM7000 Inside Base Plate Exploded View
Not all items are eld retro-ttable.

3
7000INST Copyright Lockmasters, Inc. 5/25/11
LKM7000 Front Plate Exploded View
Not all items are eld retro-ttable.
Component Part No.
Handle Screw 700012S13
Lock Washer for Handle Screw 700012S18
Intermediate Gear 700012S14
Hub Handle Half Gear 700012S01
Handle return Spring 700012S12
Outside Lever Handle 700012S11
Neoprene Handle Grip 7000HANDGRP
Complete Front Plate Assembly 700012WBA

4 7000INST Copyright Lockmasters, Inc. 5/25/11
Read instructions thoroughly prior to installation
Record the Lock’s Serial Number prior to installation:
WARNING - Must read before installation
IT IS IMPERATIVE THAT THE DOOR REMAIN OPEN DURING INSTALLATION OF THE LKM7000.
If the door closes while the back cover is removed, the relockers will trigger resulting in a lockout.
Important Information
All seals and gaskets must be applied to the door frame PRIOR to installing a LockOne Series Lock.
Compression type sound seals are NOT RECOMMENDED when using a LockOne Series Lock.
DRILLING A HOLLOW DOOR
To avoid alignment issues you should NEVER drill a through hole in a hollow door. To ensure a level through hole, you should
drill through one side of the door then drill through the other side of the door.

5
7000INST Copyright Lockmasters, Inc. 5/25/11
STAND-OFF KIT for the LockOne Series Lock
We strongly recommend using a Stand-Off Kit, which prevents a hollow metal door
from compressing during installation of a LockOne Series Lock. Stand-Off Kits are
sold separately and available for 1 3/4” and 2” doors.
PART NUMBERS: 1 3/4” Door - LKM7000SOK1
2” Door - LKM7000SOK
INTERNAL HARDPLATE
PART NUMBER: LKM7000SMHP
DOOR COVERS
When retro-tting an existing door we recommend using a set of 12” x 18” door
covers, prior to installation. Finish is powder coat black.
PART NUMBER: LKM7000DCIO (set of 2)
DOOR WEDGES
It’s a simple 3 oz. wedge of practically indestructible
lexan plastic designed to hold virtually any door at 900.
Interior or exterior, oversize, special purpose, even
pivoting glass doors.
PART NUMBER: LKMDWEDGE
Optional Products
Installation Aids

6 7000INST Copyright Lockmasters, Inc. 5/25/11
LKM7000 Strikes
Strike 1
LKM01S Strike 2
LKM02S
Strike 3
LKM03S
Strike No. 9
Strike 9
LKM09S

7
7000INST Copyright Lockmasters, Inc. 5/25/11
LKM7000 Main Components
A. Front Plate (FP)
B. Lever Handle
C. Inside Base Plate (IBP)
D. Wire Routing Box
E. 1/4”-20x 2 1/2” Socket Head
Machine Screws (4)
F. 1/4” Phillips Head Thread Forming
Screws (4)
G. 1/4”-20x1 3/4” Socket Head Machine
Screw & Washer (1)
H. 1/4”-20x1 3/4” Flat Head Phillips
Machine Screws & Finishing
Washer (2)
I. Push & Pull Decal
J. Lever Handle Grip
K. Debur Stone
L. 3/32” & 3/16” Hex Head Wrenches
M. Liquid Thread Locker
N. Change Key Hole Plug
O. Filler Blocks (2)
P. Templates
Q. Installation Instructions
R. Operating Instructions
LKM7000 Installation - Tools Needed
Drill
Wire Cutters or Strippers
Snap Ring Pliers
File
Chisel
Hack Saw
Center Punch (Automatic)
10-24 Tap & Tap Handle
Hammer
Small Pocket Screwdriver
Phillips & Flat Screwdrivers
Level & Combination Square
Tape Measure
Vise
Masking & Double Sided Tape
Scissors & Exacto Knife
1/8” Drill Bit
3/16” Drill Bit
5/16” Drill Bit
3/8” Drill Bit
5/8” Wood Cutting Bit
5/8” Hole Saw
3/4” Wood Cutting Bit
3/4” Hole Saw
1 5/8” Wood Cutting Bit
1 5/8” Hole Saw
13/64” Drill Bit
#25 Drill Bit
Safety Goggles
Rubbing Alcohol
BA
C
D
E
F
G
H
I
J
K
LM
N
O
PQ
R

8 7000INST Copyright Lockmasters, Inc. 5/25/11
For this application the LKM7000 is installed on a single hollow metal door with a #2 strike,
however the instructions apply to any strike. Please note Lockmasters has stainless
steel strikes exclusively for the LKM7000 family of locks.
Step 1 – Temporarily Installing the Strike
Step 1A – Position the center of the strike 43” on the door frame above the nished oor.
NOTE: The inside base plate should not extend beyond the edge of the door.
Step 1B – Mark the top and bottom position of the strike as well as the oversized
alignment hole in the center of the strike.
Tip: double stick tape the strike into
position to mark and punch.
Step 2 – Center punch & drill alignment/center hole
Step 2a – Center punch and drill a pilot hole with a #25 drill bit. Use an 10-24 tap and
tap the center alignment hole. Attach the strike to the door frame with the 10-24x1” pan
head machine screw provided and tighten into the center hole only. (Figure 1)
Tip: use an automatic center punch for more precise punching.
Step 3 – Prepare the Installation Templates
Begin by selecting the template that matches the appropriate door handing for the
install. Templates are provided for both right and left hand doors. Before beginning the
installation you must cut out all the areas marked with a dashed line.
LKM7000 Strike Installation
(Figure 1) ALIGNMENT HOLE
Attach the strike to the door frame by installing
only 1 screw at this time into the center hole using
the truss head screw.
1a - Strike - Center Hole 43” from nished oor.
1b - Strike - Mark the top & bottom of strike. 1b - Strike - Mark center hole.
2a - Strike - Center punch alignment/center hole.
2a - Strike - Tap alignment/center hole.2a - Strike - With a #25 bit drill a pilot hole. 2a - Strike - Attach with 10-24x1” screw.
Template - Cut out all dashed line.

9
7000INST Copyright Lockmasters, Inc. 5/25/11
Step 4 – Position the Inside Base Plate Template
Close the door and align the Inside Base Plate template over the strike and level with
the indicated horizontal level line on the template. Make sure to keep equal clearance
around the strike. Attach the template to the door with masking tape. NOTE: If the
template hits the strike. You can either reposition the template or loosen the strike
screw and adjust the strike position and retighten the screw.
Step 5 – Position the Front Plate Template
Step 5A – Make a small mark on the door’s edge in line with the horizontal level line.
Step 5B – Use the combination square to transfer that level line around the edge of
the door.
Step 5C – Use the combination square to extend that level line across the front of
the door at least 9”. This establishes a horizontal level line from the back of the door
around to the front.
NOTE - FOR BEVELED DOOR EDGE
If the door has a beveled edge, establish the high side of the bevel using the
combination square. If it has a bevel the square must be at against the door and
at against the high edge. You will see a gap between the door and the combination
square. (See Figure 2).
LKM7000 Installation
4 - Template - Center template & strike to allow
clearance.
5a - Template - Extending Inside Base Plate (IBP)
horizontal line to the edge of the door.
5b - Template - Extending Inside Base Plate (IBP)
horizontal line to the edge of the door.
5c - Template - Extending level line around to the
front of the door.
Figure 2 - Establishing the high side of a bevel edged door.

10 7000INST Copyright Lockmasters, Inc. 5/25/11
Position the Front Plate Template continued
Step 5D – Once the high side of a beveled edge door is established. Loosen the
combination square and position the rule to the vertical plumb line on the inside base
plate template and tighten the combination square. (Figure 3).
Step 5E – Transfer the vertical level line by ipping the combination square to the other
side of the door and make two marks at the end of the rule approximately 6” apart.
Step 5F – With the rule positioned on the marks draw the vertical plumb line at least 9”.
This establishes a vertical plumb line on the outside of the door.
Step 6 – Position the front plate template.
Align the vertical and horizontal lines printed on the template where they intersect with
the vertical and horizontal lines drawn on the door. Tape the template to the door with
masking tape. (Figure 4)
LKM7000 Installation
5d - Template - Determining distance of IBP
vertical plumb line.
(Figure 3) ESTABLISH VERTICAL PLUMB LINE
On the IBP template position the combination
square against the vertical plumb line.
5e - Template - Marking vertical plumb line on the
front side of the door
5f - Template - Mark vertical plumb line on the
front of the door.
6 - Template - Front of door vertical and hortizontal
lines marked.
(Figure 4) POSITION FRONT
PLATE TEMPLATE
Align front plate template to
the vertical and horizontal lines
marked on the front of the door.
6 - Template - Taping front plate template to verti-
cal and horizontal plumb lines.
Este manual sirve para los siguientes modelos
1