LINEAR LEDS LTL.BL154 Manual de usuario

Linear Technologie • 11 rue du Puits Rochefort • 42 100 Saint-Etienne
Tél: +33 (0)4 77 81 49 49 • Fax: +33 (0)4 77 81 49 40 • www.lineartech.fr V.2016
LED BAR (4 IN 1) LTL.BL154
Operation manual

2
TABLE OF CONTENTS
Page 3
Page 4
Page 5
Page 7
Page 15
1. Before you begin
2. Introduction
3. Setup
4. Operating instructions
5. Appendix

3
1. BEFORE YOU BEGIN
What is included
• 1 x Fixture
• 1 x Power cable with plug
• 1 x User manual
Unpacking instructions
Immediately upon receiving a xture, carefully unpack the carton; check the contents
to ensure that all parts are present, and have been received in good condition. Notify the
shipperimmediatelyandretainpackingmaterialforinspectionifanypartsappeardamaged
fromshippingorthecartonitselfshowssignsofmishandling.Savethecartonandallpacking
materials.Intheeventthataxturemustbereturnedtothefactory,itisimportantthatthe
xturebereturnedintheoriginalfactoryboxandpacking.
AC power
Thisxturehasanauto-switchingswitch-modepowersupplythatcanaccommodateawide
rangeofinputvoltages.Theonlythingnecessarytodobeforepoweringontheunitistomake
surethelinevoltageyouareapplyingiswithintherangeofacceptedvoltages.Thisxturewill
accommodatebetween100Vand240VAC50-60Hz.Eachlightisconnectedendtoendby
thepowersocket“POWERIN”and“POWEROUT”onthelight,orusethewaterproofpower
cord.Pleaseensuretheheadandthetailtighteningwhenconnectthelights,topreventthe
powerleakageoccurredbywaterseepagetotheplug.
Helppreservetheenvironment!Ensurethatthisproductisrecycledattheendofits
life. Your supplier can give details of local arrangements for the disposal of products.
Safety instructions
WARNING!
Pleasereadtheseinstructionscarefully,whichincludesimportantinformationabout
theinstallation,usageandmaintenanceofthisproduct.
DANGER!
Safetyhazard.
Riskofsevere
injury or death.
DANGER!
Hazardous
voltage.Riskof
lethal or severe
electricshock.
WARNING!
Firehazard.
WARNING!
LEDlight
emission.Riskof
eye injury.
WARNING!
Refertouser.

4
• Thislightbelongstogradeprotectiondevice,thereforethelightmustconnecttotheearth
excellently. And the power connection must be operated by the professional technician.
• Makesurethattheworkingvoltagewillnothigherorlowerthantheratedvalue.
• Makesurethatthecabledidn’tbedamageorlaceratedbysharp.
• Thelightmustbepowerowhenit’sstandingidleorbeforeclearing.
• Thecablemustwithplug,andyoumustpulloutthecablebyhandletheplug.
• Pleasebecarefulwheninstallingthelighting.Nevertouchthebaredcable,oritwillcause
thedeadlyelectricshock.
• Please use the suitable and safe cable to connect the light.
• Pleaseneverremodelthelightrandomly,wewillnottaketheguaranteeforthefaultyand
damage which caused by dismantle repair or remodel of the nonprofessional person.
• Maximumambienttemperature40°C.Donotoperatextureattemperatureshigherthan
this.
• Neverconnectthedevicetoadimmerpack.
• Do not daisy chain power to more than 8 units @ 120V and 12 units @ 230V.
2. INTRODUCTION
Specications
• Voltagerating:AC100V240V50-60Hz
• Powerrating:110W
• LEDquantity:15X4-in-1(RGBW)
• LED:380mA
• Beamangle:20°/30°/40°(option)
• Ingressprotection:IP65/indoor(option)
• Productsize:990X120X145mm
• Packagesize:1070X160X170mm
• N/W:5.7Kg
Features
• RGBWcolormixingwithorwithoutDMXcontroller
• Specialeect(minimum16psconegroup)
• 5 distinct dimming curves
• LEDdisplaywithpasswordprotection
• OperatingModes:DMX512connection/Master&Slave...
• DMXChannels:11/04/06/11/15/17/21/60channels

5
Product overview
Dimensions
3. SETUP
Installation requirement
Thisproductcanbeusedinavarietyofsituations,canhangandputontheground.
Ifhangingthextureforoverheaduse,thenpleasefollowthebelowsteps.
Please choose the suitable location to put or hang the light when installing it. You must use the
exclusiveclamphangerandscrewwhenhangingit,andmakesuretheweightofthelightis
within limits of the hanger.
Pleasemakesurewithoutanyammableobjectswithin0.5mwheninstallingthelight.
Theinstallationshouldbeoperatedbyprofessionalperson;anyirregularinstallationwillcause
thebodyinjuryorequipmentdamage.
Block access below the work area and use suitable and stable platform when installing or
servicingxture.

6
Connection of DMX signal wire
1. PleaseusethexturecontrollerwirespeciallywhenusetheDMX512controller.Connect
the(male)3pinconnectorsideoftheDMXcabletotheoutput(female)3pinconnectorof
therstxture.
2. Connecttheendofthecablecomingfromtherstxturewhichwillhavea(male)3pin
connectortotheinputconnectorofthenextxtureconsistingofa(female)3pinconnector.
Then,proceedtoconnectfromtheoutputasstatedabovetotheinputofthefollowingxture
and so on.
3. This product can be connected numerous lamps in series without the need for the signal
amplier;thesignalwillnotbeweakened.
3-PIN to 5-PIN conversion chart
Note:Ifyouuseacontrollerwitha5pinDMXoutputconnector,youwillneedtousea5pinto
3 pin adapter.

7
Conductor 3 Pin Female (output) 5 Pin Male (Input)
Ground/Shield Pin 1 Pin 1
Data(-)signal Pin2 Pin2
Data(+)signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use
4. OPERATING INSTRUCTIONS
Control panel functions
Button Function
Mode Exitsfromthecurrentmenuorfunction
Enter Enablesthecurrentlydisplayedmenuorsetsthecurrentlyselectedvalueintothe
selected function
Up Navigatesupwardsthroughthemenulistandincreasesthenumericvaluewhen
in a function
Down Navigatesdownwardsthroughthemenulistanddecreasesthenumericvalue
when in a function
Menu map
Main function Subfunction Selection Instruction
DMX d001 001~512 SetDMXstartaddress
Colo
R000
000~255
(0~100%)
Usercancombinered,green,blue
and white to generate a custom color
G000
b000
W000
5000 00~20 Selectstrobefrequency
AUTO
AT00 (01~50) SP00-20 Auto programs available
AP00 (01~50) SP00-20 Combine auto program
CP00 01~25 Combinecartooneects
SLAV SLA Slaves

8
Operating instructions
Enable password lock
(KEY) (ON) / (OFF){ENTER}
(ON)enablelock, (OFF)disablelock
Enable the password lock, control panel in the boot or go into standby automatically take
eect,thistimetooperatelampsneedtoenteryourpassword.{MODE,UP,MODE,DOWN,
MODE,UP,MODE,DOWN}{ENTER}
DMX512 controller mode
1. Setting DMX512 address
(DMX) (001--512)
AccesscontrolpanelfunctionbypressingMODEuntil(DMX) is displayed.
PressENTER,addorreducechannelsbypressingUP/DOWNbetween001and512.
PressMODEtoexit.
2. Setting channels
(PERS) (11CH/04CH /06CH /15 CH /17 CH /21 CH /60 CH)
AccesscontrolpanelfunctionbypressingMODEuntil(PERS) is displayed.
PressENTERbutton,selectDMXchannelbypressingUP/DOWN.
PressMODEtoexit.
Main function Subfunction Selection Instruction
PERS
11CH
Select11/04/06/15/17/21/60channel
setting
04CH
06CH
15CH
17CH
21CH
60CH
SET d1M
OFF «O»meansselectlineardimming,or
choosedimmer1-4tocontrolthe
dimmingspeed,dimming1ofthefastest
dimmingcurves,4forthemostslowly
dimming curve
DIM1/2/3/4
VER Version number
KEY ON~OFF EnablesorDisablespasswordlockout
CoMP C.SUM 01~16 Amount set of combined lights
C.id 01~16 Numbersetofcombinedlights

9
DMX512 channel values
4 channels :
Channel Value Description
1 000~255 Red
2 000~255 Green
3 000~255 Blue
4 000~255 White
Channel6haspriorityoverchannels1-5.
When activating the auto programs, then it is possible to control the auto speed by using
channel 5.
15 channels
Channel Value Description
1.LED 000 ~015 Nofunction
2.LED 016~031 R
3.LED 032 ~047 G
4.LED 048~063 B
5.LED 064~079 R+G
6.LED 080~095 G+B
7.LED 096~111 R+B
8.LED 112 ~127 R+G+B
9.LED 128 ~143 W
10.LED 144~159 R+W
11.LED 160~175 G+W
12.LED 176~191 B+W
13.LED 192~207 R+G+W
14.LED 208 ~223 G+B+W
15.LED 224~239 R+B+W
240 ~255 R+G+B+W
6 channels
Channel Value Description
1 000~255 Red
2 000~255 Green
3 000~255 Blue
4 000~255 White
5000~255 Nofunction
006~255 Strobe / Auto speed
6000~005 Nofunction
006~255 AUTO(AT01~50)

10
17 channels
Channel Value Description
1.LED 000 ~015 Nofunction
2.LED 016~031 R
3.LED 032 ~047 G
4.LED 048~063 B
5.LED 064~079 R+G
6.LED 080~095 G+B
7.LED 096~111 R+B
8.LED 112 ~127 R+G+B
9.LED 128 ~143 W
10.LED 144~159 R+W
11.LED 160~175 G+W
12.LED 176~191 B+W
13.LED 192~207 R+G+W
14.LED 208 ~223 G+B+W
15.LED 224~239 R+B+W
240 ~255 R+G+B+W
16.Strobe 000 ~255 Strobe(0~20HZ)
17. Fade 000 ~255 Dimmerspeed(fasttoslow)
11 channels
Channel Value Description
1. Dimming 000~255 0-100%
2.Red 000~255 0-100%
3.Green 000~255 0-100%
4. Blue 000~255 0-100%
5.White 000~255 0-100%
6.Macrocolorcontrol 000~009 Nofunction
010~255 Macro color control
7. Strobe 000~255 Strobe(00~20Hz)
8. Module selection
000~004 #1=ON,#2=ON,#3=ON,
005~034 #1=ON
035~064 #2=ON
065~094 #3=ON
095~124 #1=ON,#2=ON
125~154 #1=ON,#3=ON
155~184 #2=ON,#3=ON
185~214 #1=ON,#2=ON,#3=ON,
215~244 #1=OFF,#2=OFF,#3=OFF,
245~255 Convertto11CH-2
Tabla de contenidos
Manuales populares de Equipo de DJ de otras marcas

thomann
thomann Stairville DJ Lase 40-G MK-III Manual de usuario

Eagletone
Eagletone 6 Eyes Flower Manual de usuario

EuroLite
EuroLite FLD-1508 Manual de usuario

Technical Pro
Technical Pro LG8xSEA Manual de usuario

JB Systems
JB Systems Lounge Laser DMX Manual de usuario

Lightmaxx
Lightmaxx Vega Halo 90 Manual de usuario

Elation
Elation FUZE WASH Z350 Manual de usuario

Maverick
Maverick MK3 WASH Manual de usuario

Infinity
Infinity TF-260C7 Fresnel Manual de usuario

Chauvet
Chauvet EVE E-50Z Manual de usuario

Eliminator Lighting
Eliminator Lighting E 138 Manual de usuario

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Manual de usuario