Leviton INDS1-00S Manual de usuario

Leviton®Door Station
Cat. No. INDS1-00S
© 2016 Leviton Mfg. Co., Inc. DI-000-INDS1-25D
Estación de Puerta
de Leviton®
No. de Cat. INDS1-00S
Poste d’accès de
LevitonMD
No de cat. INDS1-00S
WEB VERSION

WEB VERSION

FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IC COMPLIANCE STATEMENT
Industry Canada Notice Operation is subject to the following two conditions: (1) This device may
not cause interference and (2) This device must accept any interference, including interference
that may cause undesired operation of the device.
WARNINGS AND CAUTIONS
• WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY never push objects
of any kind into this product through openings, as they may touch dangerous voltages.
• WARNING: TO AVOID DEATH OR SERIOUS PERSONAL INJURY never touch
uninsulated wires or terminals unless the wiring has been disconnected at the network
interface.
• Read and understand all instructions. Follow all warnings and instructions marked on the
product.
• Do not use this product near water - e.g., near a tub, wash basin, kitchen sink or laundry tub, in a
wet basement, or near a swimming pool.
• Never install communications wiring or components during a lightning storm.
• Never install communications components in wet locations unless the components are designed
specifically for use in wet locations.
• Use caution when installing or modifying communications wiring or components.
• SAVE THESE INSTRUCTIONS.
REGULATORY COMPLIANCE STATEMENTS
P1
ENGLISH
COPYRIGHT AND TRADEMARK INFORMATION
This document and all its contents herein are subject to and protected by international copyright and
other intellectual property rights and are the property of Leviton Manufacturing Co., Inc, its subsidiaries,
affiliates and/or licensors. Use herein of third party trademarks, service marks, trade names, brand
names and/or product names are for informational purposes only, are/may be the trademarks of their
respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement. No part of
this document may be reproduced, transmitted or transcribed without the express written permission of
Leviton Manufacturing Co., Inc.
WEB VERSION

DESCRIPTION
The INDS1-00S Leviton®Intercom Door Station with Camera is a PoE (Power over Ethernet)
device that allows streaming audio and video communications with other SIP compliant devices,
such as Leviton OmniTouch 7™ touchscreens. It features a configurable relay that can be used
to control a gate or an electric lock.
WIRING REQUIREMENTS
The INDS1-00S is an IEEE 802.3af compliant Power over Ethernet (PoE) Powered Device (PD).
The INDS1-00S receives its power over the same cable that connects the INDS1-00S to the
network, using a Power Sourcing Equipment (PSE) device, such as a PoE network switch,
hub, or power injector which provides the power. Each INDS1-00S must be installed within 100
meters (328 feet) of a Power Sourcing Equipment (PSE) device.
The INDS1-00S connects to a DHCP enabled network using a Cat-5 (4-pair) cable. Run the Cat-5
cable between the location of a PoE network switch, hub, or power injector and the location of the
INDS1-00S.
The maximum distance between the Power Sourcing Equipment (PSE) device and the INDS1-00S
and is 100 meters (328 feet). Terminate both ends of the Cat-5 cable with 8-position modular
connectors to make a standard straight through network patch cable.
When switching voltage through the relay in the INDS1-00S, run a separate power cable from
a power supply to the INDS1-00S and a control cable from the relay on the INDS1-00S to an
electric lock or gate controller.
INSTALLATION
The INDS1-00S Leviton Intercom Door Station is designed to be installed into the provided metal
backbox.
When selecting a place to mount the INDS1-00S, be sure to avoid an area where studs, plumbing,
or electrical wiring may be located behind the wall. It should be mounted so that the display is
at or slightly below eye level.
Route the network cable, optional power cable, and optional control cable through the desired
knockout opening in the metal backbox. There are knockouts on the bottom, back, and lower
right and left side of the metal backbox.
Mount the metal backbox into the opening in the wall so that arrow is facing up. The metal
backbox should be mounted flush with the surface of the wall opening or slightly behind the
surface of the wall opening.
P2
WEB VERSION

With the backbox securely mounted in the wall opening:
1) Screw the 3 supplied studs into the 3 respective standoffs on the metal backbox
(Figure 1).
2) Place the plastic backbox into the metal backbox so that the back of the plastic
backbox sits flush against the metal backbox (Figure 2).
3) Screw the 3 supplied nuts onto the 3 respective studs:
• If the metal backbox is flush with the surface of the wall opening, screw the nuts until they
touch the standoffs.
• If the metal backbox is slightly behind the surface of the wall opening, screw the nuts so
that they are slightly suspended on the stud. The nuts may need to be adjusted to achieve
the proper fit.
4) Insert the 8-position modular connector of the network cable into the RJ-45 connector on the
door station, through the cutout in the plastic backbox.
5) If used, connect the controlled device and/or power supply to the relay outputs marked
R-NO/R-NC and R-COM.
P3
Figure 1 Figure 2
ENGLISH
WEB VERSION

6) Place the door station on top of the metal backbox. While holding the door station in place,
screw the 4 supplied screws into the openings on the top and bottom of the door station
(Figure 3). Make sure the screws attach into the slots on the plastic backbox. Gently tighten
the screws until the door station is securely fastened to the backbox. Do not over tighten the
screws.
7) Insert the top and bottom overlays into the respective mounting holes until they snap in
place (Figure 4).
P4
Figure 3
Figure 4
WEB VERSION

OBTAINING THE IP ADDRESS OF THE LEVITON DOOR STATION
By default, the Leviton Door Station obtains an IP address from the DHCP server on
the local network. The IP address of the Leviton Door Station can be discovered by
using the discovery tool in Leviton PC Access Software, Version 3.16 or later.
1. Using Leviton PC Access Software, under Extended Setup, click on SIP
Stations.
2. Add a SIP Station by clicking on the green plus icon on the toolbar.
3. With Leviton selected in the Station Type drop-down, click the Discover button. The
Discover Leviton Door Stations dialog box will appear with any Leviton Door Stations that
are discovered.
4. To add the Leviton Door Station to Extended Setup, highlight the desired door station from
the Discover Leviton Door Stations dialog box and press OK.
P5
ENGLISH
WEB VERSION

5. Make note of the IP Address of the SIP Station.
CONFIGURING THE DOOR STATION
The Leviton Door Station is configured using its built-in web interface. To access the web interface:
1. Open a web browser and type the door station’s IP address into the browser’s address bar.
For example: http://10.0.0.196
2. When the Door Phone Control Center dialog box is displayed, click the Login button.
P6
WEB VERSION

3. When the Windows Security authentication dialog box is displayed, enter the User
name and Password to access the device.
The default credentials are:
User name: admin
Password: admin
The System Information page is displayed, which gives Device Information,Network,
and SIP Phone Information.
4. To configure the network settings of the Leviton Door Station, select Network from the main
menu, and then select Network from the context menu.
To select a static IP address (recommended), select Static from the Type drop-down menu.
Then enter the desired static IP Address, Subnet Mask, Gateway, Primary DNS, and
Secondary DNS for the local network.
When complete, click Save.
P7
ENGLISH
WEB VERSION

5. To configure the SIP settings of the Leviton Door Station, select Phone from the main menu,
and then select SIP from the context menu.
a. In the edit box next to SIP Proxy / P2P Bridge, enter the IP address of the SIP server.
b. In the edit box next to SIP Service Domain, enter the IP address of the SIP server.
c. In the edit box next to Display Name, enter the name of the door station as it will be
displayed on the touchscreen. This name should match the name that is entered under
SIP Station Name in PC Access.
d. In the edit box next to Phone Number, enter the SIP Username that was assigned to the
door station in the SIP server.
e. In the edit box next to Password, enter the Password that the door station uses to
register with the SIP server.
f. When complete, click Save.