Lec+ Club LE Manual de usuario

Club LE Pedicure Chair
USER MANUAL
1-400-0022 • Rev F • 5/2/21
© Living Earth Crafts 2020, All Rights Reserved
*shown with oponal accessories and/or nishes

© Copyright 2020
Living Earth Cras®
All rights reserved. is document or any
portion thereof may not be reproduced
in any way, including photocopying or
translation to another language without
the prior written permission from Living
Earth Cras.
Living Earth Cras® is a registered trade-
mark of Earthlite, LLC,
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Living Earth Cras®.
Living Earth Cras® assumes no responsibility for the
accuracy or suitability of the information contained in
this document. is document may contain technical
inaccuracies or errors. Living Earth Cras® makes no
expressed or implied warranties of any kind concerning
the information contained in this document, including,
but not limited to, the implied warranties of merchant-
ability and tness for purpose.
Living Earth Cras® shall not be liable for incidental or
consequential damages in connection with or arising out
of the product, performance, or use of this document
and the information and material it describes.

Introduction
Congratulaons on your purchase of the Club LE pedicure chair. The Club LE oers an unparalleled
pedicure and hydrotherapy experience, featuring a luxurious, handcraed chair and a jeed tub.
The tub basin is lined with soothing textured foot pebbles to give your client’s feet a relaxed,
massaging sensaon.
The Club LE is designed for licensed therapists and technicians and is intended to be used in a
professional spa, salon, or similar commercial environment. While no special training is needed
to operate the product, for safety reasons it is important that the instrucons contained in this
manual are reviewed in detail before the rst use. This manual should be read in its enrety by
each professional who will be operang the product to ensure the safety of both operator and
client. This manual should be saved for future reference.
The Club LE should not be used in any other manner than described in this manual. Please read,
understand, and follow all safety warnings, labels, and instrucons. Misuse, use of unnecessary
force, or using the chair for unintended or unauthorized procedures can result in injury to
operator, client, and/or equipment.
Detailed instrucons for use and maintenance can be found in this user manual. If you have
further quesons, please contact us at (800) 358-8292 for US customers, or (760) 597-2155 for
internaonal customers. We can also be reached via e-mail at info@livingearthcras.com
Secon 1: Safety Informaon
Safety Symbols/Warnings
Secon 2: Product Overview
Product Diagram
Product Specicaons
Secon 3: Operang Instrucons
Retractable Tub
Power Back Tilt
Water Fill Valve
Jet & Light
Drain Release & Discharge Pump
Footrest Operaon
Electrical Specicaons
Swingaway Manicure Trays
Relaxor
Secon 4: Care & Maintenance
Cleaning & Ongoing Maintenance
Tub Cleaning Guide
Troubleshoong
Warranty Informaon
Secon 5: Installaon
Technical Drawings
Backow Prevenon
Contact Us
2-3
4
5
6
6
6
7
7
8
8
9
10
11
12-13
14
15
16-17
18-19
back cover
Table of Contents

READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using this product.
Safety Symbols
Familiarize yourself with the following
Safety & Warning symbols. They are
designed to prevent damage and injury
to you, your clients, and your new Living
Earth Crafts product.
IMPORTANT: The important safety
instructions and warnings in this manual
cannot cover all possible problems and
conditions that can occur. Use common
sense and caution when installing,
operating, or maintaining this appliance.
Indicates an imminently hazardous
situation which could result in serious
or fatal injury.
Indicates a potentially hazardous
situation which could result in serious
injury.
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
SECTION 1: SAFETY INFORMATION
RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT USE
DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN
OR HANDICAPPED PERSONS SHOULD NOT USE WITHOUT
SUPERVISION.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconsciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its
intended purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of
reach of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR HEALTH.
CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

READ AND SAVE THESE INSTRUCTIONS 3
SECTION 1: SAFETY INFORMATION
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water lled 1 inch above jet.
• DO NOT overll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• DO NOT retract tub when water is in basin.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jet and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A qualied plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
• Chair and tub are to remain right side up. At no time should chair or tub be turned on it’s side or upside
down.
1. RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault
circuit-interrupter.
2. Grounding is required. The unit should be installed by a qualied service
representative and grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock. Check
with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by
a qualied electrician.
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
Reset
Button
GFCI Outlet
Grounding Pin
Test
Button

SECTION 2: PRODUCT OVERVIEW
4
Swingaway Tray
Storage
(Optional)
Footrest
Adjustment
Button
Sprayer/Fill
Light Button
*Chair shown with oponal nishes
Footrest
Tub Jet
Tub Basin
Swingaway Manicure Tray
(Optional)
Jet Button
Water Fill
Valve
Drain Release
Ventilation
(Optional)
Power
Back Control
Power Drain
Button

*Measurements may vary due to natural material variaons.
5
Feature Standard Oponal
Pipeless Jet X
Reexology Acrylic Tub X
Power Back Tilt X
Fully Motorized Footrest X
Motorized Retractable Tub X
Power Drain/Discharge
Pump X
Venlaon X
Relaxor® Heat & Massage X
Swingaway Manicure Trays X
Avonite/Glass Top Standard Opons Upgraded Opons
Upholstery Nature’s Touch
Promessa®,
Ultraleather®, or Urban
Fabrics
Included Features
Product Specications
Overall Width 31” (79 cm)
Tub/Shroud Width 25.25” (64 cm)
Tub Height (to footrest) 16.5” (42 cm)
Length (chair only) 35” (89 cm)
Length (chair w/tub) 57.5” (146 cm)
Chair Height 50.25” (128 cm)
Seat Height 22” (56 cm)
Backrest Tilt 15 degrees
SECTION 2: PRODUCT OVERVIEW
Ventilation
(Optional)

SECTION 3: OPERATING INSTRUCTIONS
Retractable Tub Operation
Always use extreme cauon when making any posion adjustments to your
chair/tub. Ensure all body parts and objects are clear from all moving parts.
Push & hold to
retract tub
Push and hold to
extend tub
Light Button
Water Fill Valve
There is no automac shuto with the water ll valve. You MUST turn the
valve OFF aer the tub is lled to prevent overow and/or ooding. Do not
walk away from the tub when it is lling with water.
Down-OffUp-FillLeft-Cold Right-Hot
The water ll valve is OFF when poinng DOWN. Water dispenses when you pull the valve UP.
For hot water, turn valve to the RIGHT. For cold water, turn valve to the LEFT.
Power Back Tilt Operation
Your chair is equipped with a power recline buon located on the inside of the right arm of
the chair. See below for instrucons on how to operate.
Increase Back Tilt
Your Club LE has a tub that conveniently retracts underneath the chair for manicure posioning.
6
DO NOT retract tub when water is in the basin.
Decrease Back Tilt
Jet Button

SECTION 3: OPERATING INSTRUCTIONS
7
Pipeless Jet & Chromasoothe Light
Pressing the respecve On/O buon once will turn on the jet or light, and pressing the buon
again will turn it o. Turn on the jet ONLY AFTER the tub is lled with water, and ensure you
turn the jet OFF before draining the tub.
Running the jet without lling the tub with water can damage or destroy
the jet. Ensure that a MINIMUM of one (1) inch of water is above the jet
prior to use.
Light Button
Jet Button
Drain Release & Discharge Pump Operation
• Turn the drain knob clockwise to close the drain when lling the tub.
• Turn the knob counterclockwise to open the drain and empty the tub.
• Discharge pump buon is locaon directly below the jet/light buon. Before pressing the
buon, open the drain with the drain knob and let the water start draining towards the
pump. Wait approximately 5-10 seconds for the pump to register, then push the discharge
pump buon.
Discharge
Pump
On/O Buon
Drain
Release

SECTION 3: OPERATING INSTRUCTIONS
8
Footrest Operation
Always use extreme cauon when making any posion adjustments to your
footrest. Ensure all body parts and objects are clear from all moving parts.
Do not sit on or put full body weight on the footrest. It is meant only to
support a client’s feet for a pedicure, not to support body weight.
Push & hold to
raise footrest
Push and hold
to lower
footrest
Electrical Specications
Spec North America Europe/Asia
Input Voltage 120 VAC 220 VAC
Input Frequency 60 Hz 50 Hz
Total Consumpon
- Standard Features 5.9 Amps, 708 Was 3.2 Amps, 708 Was
Consumpon -
Relaxor Addional 4 Amps, 480 Was Addional 2.2 Amps, 480 Was
Discharge Pump Specication
Motor Design Single-phase synchronous motor
Flow Rate (120V) 24 l/min at 0, 1 bar
Flow Rate (220V) 20 l/min at 0, 1 bar
Duty Cycle Connuous
Este manual sirve para los siguientes modelos