LeakSmart PROTECT Manual de usuario

PROTECT
by LeakSmart
Flow Meter Shut-o Valve System
User Manual

2 3
Installation Overview:
In the Box.................................................................................................................................. 4
Setup Requirements.............................................................................................................6
Important Installation Information................................................................................7
Section I:
LeakSmart Hub 3.0 Pre-Installation Customer Setup
Requirements...........................................................................................................................9
Section II:
LeakSmart Hub 3.0 Installation.....................................................................................10
Performing a Factory Reset............................................................................................13
Connect the Hub to the Home Wi-Fi Network.....................................................15
Protect by LeakSmart Setup..........................................................................................16
Pair the Protect by LeakSmart to the Hub 3.0.......................................................18
Test Local and Remote Control of the Valve Control Head..........................20
Table of Contents Table of Contents
Section III:
Protect by LeakSmart Flow Meter Shut-O Valve Installation ...................22
Pre-Installation Assembly................................................................................................22
Installation Assembly.........................................................................................................24
Protect by LeakSmart Validation................................................................................30
Section IV:
Sensor Setup and Operation........................................................................................32
Place and Test Sensors....................................................................................................36
Alert Setup.............................................................................................................................40
Adding Alert Contacts.....................................................................................................40
Test Leak Simulation..........................................................................................................41
Clearing Test Leaks............................................................................................................41
Test Flow Analytics.............................................................................................................42

4 5
Valve Control Head
Shut-o Valve
Coupling
Flow Meter
Hub 3.0
Sensors (3)
AA Batteries (4)
AAA Batteries (9)
Valve Control Head AC Power Adapter (18’ reach)
Hub AC Power Adapter (6’ reach)
Setup Manual
Hub 3.0 Lithium Battery (Pre-installed)
In the Box:
Not Pictured:
1
3
5
7
2
4
6
8
9
10
11
Note: Additional ttings may be required based on
installation requirements.
Encuentra nuestro manual en español en LeakSmart.com/support/manuals/
1
2
3
7 8 11
5
6
910
4

6 7
CAUTION:
• Do not install on re suppression systems/re sprinkler water lines.
• Never place your ngers inside the Shut-o Valve or Flow Meter.
• Do not grip the plastic motor drive for leverage when installing
the valve.
• LeakSmart recommends compliance with all local building and
safety codes when installing the Protect by LeakSmart System.
• LeakSmart Hub and Sensors are for indoor use only.
• For outdoor use of the valve, utilize the approved enclosure box
available from LeakSmart.
To set up the LeakSmart System, you need:
• Wi-Fi
• An iOS or Android phone or tablet
• A free LeakSmart account
Setup Requirements Important Installation Information
Note: LeakSmart devices in the home communicate
on a local zigbee RF network and do not require Wi-Fi
to protect your home. Wi-Fi is required for intital set
up and notications.
Professional installation recommended.
5-year LeakSmart warranty when purchased and
installed by a professional. All other purchases and
installations include a 2-year warranty.

8 9
Before installing the LeakSmart Hub 3.0, the customer needs an active
LeakSmart account to register the hub.
Download the LeakSmart app from the Apple App Store or
Google Play on your smart phone or tablet.
Open the app and tap create an account.
Follow the instructions in the app to create your account.
Create a password that:
• Is between 8-19 characters
• Has at least one number or special character
• Has at least one capital letter and one lower case letter
LeakSmart Hub 3.0 Pre-Installation Customer Setup Requirements
The homeowner’s Wi-Fi network and password are
used to activate the hub. It’s best practice to get that
information before starting the installation process.
2
3
4
5
6
7
1
Activate Account
Go to your email.
Open the email from noreply@mywateralerts.com.
Tap the activate your account link in the email.
Look for the on-screen conrmation.
Log in to your account in the LeakSmart app.
LeakSmart Hub 3.0 Pre-Installation Customer Setup Requirements
2
4
5
1
3
Note: Your email will be your LeakSmart account name.
Tap Next.
Review your information and agree to the terms of use.
Tap Submit to create your account.
After you create the account, activate and verify the account.

10 11
Place the hub in a location central to the other LeakSmart
devices.
Plug the hub 3.0 in, using the AC power adapter cord.
• The hub 3.0 cannot be registered/activated on battery
power; it must be plugged in.
• The included lithium batteries are intended to be a
backup in the event of a power outage.
LeakSmart Hub 3.0 Installation LeakSmart Hub 3.0 Installation
3
2
3a
Slide the
on/o
button to
the ON
position.
Central location:
place hub in a
location central to
other devices.
A solid red
light on top
of the hub
indicates
that it’s on.
Plug in AC adapter cord.
Slide the on/o button on the back of hub to the ON position.
• A solid red light on top of the hub indicates that it’s on.
2
13
3a
1

12 13
LeakSmart Hub 3.0 Installation
Log into the LeakSmart app with homeowner/customer
account credentials.
Tap Add Hub.
Back out of - but do not close - the LeakSmart app.
Open the phone or tablet settings.
Open Wi-Fi settings.
• The LeakSmart Hub should appear in your list of available
networks as LeakSmart-XXXX.
• The four-digit code is the last four digits of the MAC
address of LeakSmart Hub. (You can nd this number on the
battery door of the Hub).
Conrm that you have successfully connected your phone or
tablet to the LeakSmart-XXXX network.
Return to the LeakSmart app.
4
5
6
7
8
Note: If the LeakSmart Hub network does not
appear, perform a factory reset.
Use a pin (or something with a thin tip) to press
and hold the factory reset button on the back of
the LeakSmart hub for fteen-seconds.
• A purple light on top of the hub indicates that the hub is
ready for factory reset.
Turn the hub o, then back on.
The LeakSmart hub will then show up on the Wi-Fi network.
Tap LeakSmart-XXXX to join the network.
Performing a Factory Reset (If Needed)
2
3
4
1
1a
10
91a
A purple light on
top of the hub
indicates that the
factory reset is
complete.
Press and hold
the reset button to
perform a
factory reset.
1
Turn the hub
o/on. 2

14 15
Connect the LeakSmart Hub 3.0 to the Home Wi-Fi Network
Tap the name of the homeowner’s Wi-Fi network.
(network must be 2.4GHz in order to work).
Type the homeowner’s Wi-Fi password
in the password eld.
Tap Connect.
A solid blue light on top of the hub indicates that the hub is
connected to the home Wi-Fi network.
LeakSmart Hub 3.0 Installation
11
12
13
14
Note: After connecting to Wi-Fi, the hub will register
itself on the cloud and should appear in the app.
The hub’s LED
indicator will turn blue
when successfully
connected to the
home Wi-Fi network.
14

16 17
Open the LeakSmart app and tap Add Devices.
For the valve control head, use a Phillips head screwdriver to
open the battery compartment and install four AA batteries.
Connect the jack of the 9V Supply Cord to the bottom of the
valve control head. Then, plug the 9V Supply Cord into
an outlet.
CAUTION:
• Do not replace the four AA batteries with a 9V battery; this will
void the warranty.
• If the provided AC power cord isn’t long enough to reach the
outlet, be sure to replace it with a low voltage extension cord.
We recommend the LeakSmart low voltage extension cord.
Protect by LeakSmart Setup Protect by LeakSmart Setup
1
2
3
Keep the LeakSmart valve control head connected
to the shut-o valve and place it at the installation
location, so you can verify that it is within
communication range to the hub.
Power the unit:
Battery compartment: open with a Phillips
head screwdriver and install (4) AA batteries.
2
9V Supply Cord Jack: plug cord into outlet after insertion.
3

18 19
Pair the Protect by LeakSmart to the Hub 3.0 Pair the Protect by LeakSmart to the Hub 3.0
Tap Next in the LeakSmart app to initialize a three-minute
pairing mode.
• A green light on top of the hub indicates that it’s in pairing
mode.
• A blue light on top of the hub indicates that the three-
minute pairing mode has ended.
A double blue light on the valve control head indicates that it’s
ready to be paired.
Tap Next in the LeakSmart app.
Press and release the center button on the valve control head
to pair it to the hub.
When the valve control head rapidly ashes blue, or all the
lights turn o, you’ve successfully paired it to the hub.
• Verify that the valve appears in the app before moving on.
1
2
3
4
5
Note: The valve may take up to one minute to pair
and populate in the app.
Green light: pairing mode is active.
Blue light: pairing mode has ended.
Rapid blue
light/no lights:
successfully
paired.
Center button: press and
release to pair to the hub.
Double blue light:
pairing mode is active.
1
4
5
2
Tabla de contenidos
Otros manuales de Dispositivo de protección de LeakSmart


















