LCPRO SHARKi Manual de usuario

SHARKi
IP66 BEAM Movinglight
User Manual
V1.1

Table of contents
1. SAFETY INSTRUCTIONS..........................................................................................................................................1
2. PRODUCT INTRODUCTIONS...................................................................................................................................3
2.1 DIMENSIONS .............................................................................................................................................................3
2.2 FIXTURE OVERVIEW .................................................................................................................................................4
2.3 ACCESSORIES ...........................................................................................................................................................4
3. PACKING AND SHIPPING.........................................................................................................................................5
3.1 PROTECTION LOCK.............................................................................................................................................5
3.2 UNPACKING ..........................................................................................................................................................5
3.3 PACKING AFTER USE ................................................................................................................................................5
4. INSTALLATION ................................................................................................................................................................6
4.1 CLAMPS INSTALLATION ...................................................................................................................................6
4.2 DEVICE INSTALLATION .....................................................................................................................................6
4.3 LAMP FITTING AND ADJUSTMENT ............................................................................................................................7
5. POWER / CONTROL CONNECTION .................................................................................................................................8
5.1 POWER CONNECTION ................................................................................................................................................8
5.2 CONTROL CONNECTION...................................................................................................................................8
5.3 TESTING.................................................................................................................................................................8
6. CONTROL PANEL ............................................................................................................................................................9
6.1 PANEL INSTRUCTION ................................................................................................................................................9
7. TECHNICAL SPECIFICATION ..........................................................................................................................................10
8. GOBOS AND COLORS.............................................................................................................................................12
8.1 GOBOS..................................................................................................................................................................12
8.2 COLORS................................................................................................................................................................12
9. MENU STRUCTURE .................................................................................................................................................13
10. DMX PROTOCOL ....................................................................................................................................................16
11. SYSTEM WIRING DIAGRAM ...............................................................................................................................18
12. MAINTENANCE AND TROUBLESHOOTING....................................................................................................19
12.1 CLEANING AND MAINTENANCE.................................................................................................................19
12.2 TROUBLESHOOTING......................................................................................................................................19

1
1.Safetyinstructions
Beforeusingthefixture,readthelatestversionoftheproductusermanual,payingparticularattentionto
thesafetyinstructions.
m
ta
tc
The manufacture of this fixture, are not responsible for damages, resulting from misuse of this
fixture,duetothedisregardoftheinformationprintedinthisusermanual.
DANGER!
Hazardousvoltage.Riskoflethalorsevereelectricshock
WARNING!
Wearprotectiveeyewear.Neverlookdirectlyintothelightsource.
WARNING!
Burnhazard.Hotsurface.Donottouch.
Onlytodirectmountingonnon-combustiblesurfaces.
Minimumdistancetolightedobjects.
Replaceallcrackedglassshields.
Maximumambienttemperature.
Maximumtempoftheexternalsurface.

2
General guidelines
lThis product has a protection rating of IP66.
lNever open this fixture while in use.
lThe fixture should be kept clean. DO NOT operate the fixture in extreme heat or dusty environments. Avoid contact
with chemical liquid.
lMinimum distance to lighted objects must be 49.21feet (15m).
lMaximum temp of the external surface 194˚F (90˚C).
lMaximum ambient temperature 113˚F (45˚C).
lMinimum distance of inflammable materials from the surface 1.6 feet (0.5m).
lLamp should be changed if damaged or distorted in shape due to extreme heat.
lCover, prism or LCD Menu Function Display with visible damages such as cracks or scratches must be replaced to
ensure performance of the fixture.
lDisconnect the fixture from power before changing any parts or accessories.
lBasic insulation should be maintained between the controllable device and the product power supply.
lMake sure that the installation area can hold a minimum point load of 10 times the weight of all installed
fixtures, clamps, cables, auxiliary equipment, etc. Check that the cover, clamps and locks are undamaged. Certified
safety cables must always be used when installing the fixture.
lThe fixture is only intended for installation, operation and maintenance by qualified professional. Instructions stated in
the manual must be complied.
lThe fixture must be kept in a well-ventilated place at least 50 cm away from any wall surface. Check if the fans or
ventilation openings are unblocked.
lThis fixture uses discharge lamp. To avoid reducing the lamp’s life, wait at least 15 minutes after powering off to allow
the unit to cool down before handling.
lBroken or damaged cables and light source can only be fixed or changed by certified technicians, certified local
distributors or the manufacturer to ensure operational safety.
lDo not stick filters or other materials onto the lens. Do not modify the fixture or install other manufactured parts.

3
2. Production instructions
2.1 Dimensions

4
2.2 Fixture overview
2.3 Accessories
Item Qty Unit Remark
User Manual 1 Pc --
Clamps 2 Set Hanging integrated folding lamp, Load weight 200KG
Safety cable 1 Pc Φ5*60cm 7*19 pc with hook Material:Steel
5-pins signal line 1 Set --
Power cable 1 Set 1.5*2.5mm2

5
3. Packing and shipping
3.1 Protection lock
Pan and tilt locks are equipped to ensure safe transportation.
PAN: 4 lock positions are located evenly on the Pan.
3.2 Unpacking
Notes
All products are quality controlled and checked for any faults before they are dispatched to customers. If the fixture is
damaged during delivery, the customer must notify the shipper and manufacturer to file a damage insurance claim.
Photographic evidence of the damage must be provided.
Flight-Case:Open the cover of the flight-case and remove the plastic packing bags. Hold the handles of the fixture firmly
and take it out carefully.
Cardboard box:Open the box and take out the whole set of packaging foam which contains both the fixture and its
accessories. Remove the foam from the top, put away the accessories, and then take out the fixture wrapped in the plastic
bag.
Notes
Check if the pan and tilt are unlocked before connecting the fixture to power.
3.3 Packing after use
1. Switch off the fixture and wait for at least 5 minutes before disconnecting it from AC power. Cool down the fixture for
at least 15 minutes before packing.
2. Lock pan and tilt.
3. Flight case: Wrap the fixture in plastic bags. Hold it by the handles, and then carefully place it inside the flight case
along with all the accessories. Close the cover. Only 3 layers are allowed when piling up the flight cases. Do not upside
down.
4. Cardboard box: Wrap the fixture in plastic bags. Put it in the packaging foam along with all the accessories. Place the
other set of packaging foam on top then carefully put it inside the cardboard box.
水平保
护锁
P a n l o c k

6
4. Installation
4.1 Clamps installation
The fixture can be placed on the stage or mounted on the truss facing any direction. Attach the clamps to the mounting
position on the base of the fixture.
Warning:Use two clamps when mounting the fixture. Turn the screws attached to each clamp a 1/4 turn clockwise to lock.
Always remember to use the safety cable which goes through the mounting hole on the base. Do not attach the safety cable
on the handle.
4.2 Device installation
1. Make sure there is no damage on the clamps or safety cables before installation.
2. The clamp is mounted on the chassis of the fixture. Horizontally insert the clamp into the mounting holes of the chassis.
Fasten the clamp tightly by a 1/4 turn clockwise. Fix another clamp in the same way.
3. Check if pan is unlocked before connecting the unit to AC power.

7
4.3 Lamp fitting and adjustment
1. Disconnect the fixture from AC power. Cool down the fixture. Set the Tilt lock in a horizontal position.
2. Remove the lamp holder lower cover and plug out the waterproof terminal when disassemble the bulb, then loosen the
fixed plate and take out the bulb.
3. Put the bulb into the fixed plate, then press the bulb clockwise with the fixed plate when install the bulb, observe the bulb
spot and adjust it after lighted the bulb. Finally, plug in the waterproof fan and lamp holder lower cover.
Note
The fixture is equipped with PHILIPS MSD Platinum Flex 300S, which is featured with high efficiency and short-arc
characteristic, such as a stable 7200K color-temperature and average lifespan of 6000h.
Note
1. Fitting another type of lamp will cause potential damage to the fixture. Change the lamp before it reaches its lifespan.
Read the guidelines in the package carefully when fixing the lamp.
2. To avoid any impact on the beam, do not touch the bulb with your bare hands. The lamp must be kept clean with the use
of the clean paper contained in its package
Push the light bulb to the
hole,press it down
Enlarged
Remove the back
Back cover
Back cover
cc

8
5. Power/ Control connection
5.1 Power connection
Connection method:
ŸL (Live) Brown wire
ŸE (Earth) Yellow / Green bi-color wire
ŸN (Neutral) Blue wire
ŸThe voltage and frequency of the power source must be in compliance with the ones marked on the fixture. It is
strongly recommended that each fixture are to be connected to the power source separately so that they can be
switched on / off individually.
5.2 Control connection
The fixture has 5-pin XLR connectors for DMX data input and output as shown below. Connection between the console and
fixture, and between fixtures must be made with 2 core screened DMX signal cable. Maximum connecting distance of
signal cable is 150 meters. Additional DMX512 signal-amplifier is recommended for longer distance
Connect the Console’s DMX OUTPUT to the first fixture’s DMX INPUT, then the first fixture’s DMX OUTPUT to
the second fixture’s DMX INPUT and so on. It is recommended not to connect more than 32 units on a single
DMX universe. On the last fixture’s output connect a DMX terminator. (The terminator is a 5-pin XLR connector
with a 1/4W and 120Ωresistor between the pin 2 and pin 3) as shown below:
5.3 Testing
Connect the fixture to AC power. Check if the lamp is on and the fixture is independently controllable before
putting into operation.
Tabla de contenidos
Otros manuales de Equipo de iluminación de LCPRO
Manuales populares de Equipo de iluminación de otras marcas

Qazqa
Qazqa Suplux SL 3 Black 103062 Manual de usuario

Commercial Electric
Commercial Electric 54568141 Manual de usuario

CREE LIGHTING
CREE LIGHTING 304 Series Manual de usuario

Goobay
Goobay 49867 Manual de usuario

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manual de usuario

Alkalite
Alkalite Krypton KT-81 Manual de usuario












