Lanoptik HD62 Manual de usuario

LANOPTIK TECHNOLOGIES LTD
HDMI Digital Microscope
HD62
User Manual

HD62 User Manual
Content
CHAPTER 1 NOTES AND SAFETY REQUIREMENTS ------------------------------------ 1
1.1 Cautions and Notes -----------------------------------------------------------------1
CHAPTER 2 PACKING LIST ------------------------------------------------------------ 2
CHAPTER 3 FUNCTION INTRODUCTION OF EACH PART----------------------------- --3
3.1 Name and Function for Each Part of Microscope ----------------------------------- 3
3.2Accessory Introduction ------------------------------------------------------------ - 5
CHAPTER 4 INSTALLATION GUIDE -------------------------------------------------- --6
4.1 Methods of application of electron microscope -------------------------------------6
CHAPTER 5 DIGITAL CAMERA INSTRUCTIONS ---------------------------------------- 8
5.1 Instruction of manual focusing knob on the top of the digital camera ------------ -- 8
5.2 Introduction of buttons functions -------------------------------------------------- -8
5.3 Articulating arm adjustment‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐--------------------------------------------------‐‐ 9
5.4 Introduction of buttons functions‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐--------------------------------------‐10
1) Picture --------------------------------------------------------------------------- 10
2) Record --------------------------------------------------------------------------- 10
3) Playback ------------------------------------------------------------------------- 10
4) Freeze -------------------------------------------------------------------------- -11
5) Menu Setup-----------------------------------------------------------------------11
6) Exposure Setup ------------------------------------------------------------------ 11
7) White Balance Adjustment ------------------------------------------------------- 12
5.3 Read TF card -----------------------------------------------------------------------13

HD62 User Manual
www.lanoptik.com
- 1 -
Chapter 1 Notes and Safety Requirements
1.1 Cautions and Notes
(1) To avoid danger or damage incurred to the lens, do not touch the lens
or sensor directly with your fingers.
(2) To avoid failure or electric shock hazard and so on, do not disassemble
or modify the internal structure of the device.
(3) Do not plug in or unplug the Power connection port when hands are wet.
(4) Do not use alcohol and other organic solvents to clean.
(5) If the lens or sensor is dirty or damp, you should better use dry
and non-linen fabric or professional lens tissue to wipe them. To
avoid scratches on the surface, do not touch the lens with your fingers.
Wipe the lens or sensor lightly.
(6) The products are not specifically designed for an outdoor use. Do
not expose it to outdoor environment without any protection.
Excessive temperature and humidity will damage the lens. Please
avoid using the product under the following environment: high
temperature or high humidity environment, places with direct
sunlight, dirt or vibration and places near heat source.
(7) Please use and store in the following environment:
Operating temperature :0℃~ 40℃
Storage temperature:-20℃~ 60℃
Operating Humidity:30~60%RH
Storage Humidity:10~80%RH
(8) If any foreign matter, water or liquid enter into the device by
accident, disconnect the Power line immediately. Please send it to the
maintenance center and do not use the hair dryer to dry it by yourself.
(9) To prevent microscope from being tripped over or dropped, please
put away the device's connect cable in use or standby.
(10) To avoid electric shock by accident, please power off microscope
before you move your display or equipment.
(11) The cleanliness of the device lens will directly affect clarity degree
of contents from the computer screen during preview. Problems like
various circles or spots on the screen may mostly be incurred by dirt
on the lens. When cleaning, please use professional lens tissue or
other professional detergent to clear the dirt on the lens.

HD62 User Manual
KS064300G4-Ver1.1
- 2 -
Chapter 2 Packing List
1. .Imaging part and arm 2. Monitor 3. Base
4. Upright column 5. Hand shank 6. AC/DC adapter
7. HDMI cable 8. USB cable 9. inner hexagon spanner 10. Installation disk
11. Installation Guide 12. Reset pin 11. Wired controller (optional accessories)

HD62 User Manual
KS064300G4-Ver1.1
- 3 -
Chapter 3 Function Introduction of Each Part
3.1 Name and Function for Each Part of Microscope

HD62 User Manual
KS064300G4-Ver1.1
- 4 -
1. Monitor
2. Focus knob
3. Buttons
4. Switch
5. Monocular microscope
6. Magnification
adjustment ring
7. Base
8. TF card slot
9. HDMI port
10. Reset
11. USBport
12. Monitor switch
13. USB power supply
interface
14. HDMI interface
15. Wired controller
interface
12.5"monitor,For image display and USB power supply
interface.
Rotate the knob to implement the focus function; Rotate
clockwise: back focal length decreases and object
distance increases; Rotate anticlockwise: back focal
length increases and object distance decreases.
In HDMI mode, 5 buttons can match to each other to
achieve different functions.
Put the switch to right: turn on the digital camera; put the
switch to left: turn off the digital camera.
Electronic eyepiece adopts standard C port. You can adjust
the magnification ratio of the microscope according to
requirements to realize object observation under different
magnification ratio
Adjustment range 0.7-5 times.
Aluminum alloy base with scratch-resistant film on the
surface.
The location of TF card, photos and videos will be stored in
TF card.
Connect to the monitor with HDMI cable for signal
transmission.
Press and hold for more than 3 seconds to restore factory
settings.
Used for the connection between the camera and the
monitor, which supplies power to the camera.
When the switch is turned up, the monitor is turned on;
when the switch is turned down, the monitor is turned off
(the digital camera stops working after the monitor is
turned off).
It is a 5V 2A power output interface, provide-power to
digital camera through USB cable.
Connect to the digital camera through HDMI
cable to receive the signal from digital camera.
Connect to the wired controller which is an optional
accessory to adjust parameters of the monitor.

HD62 User Manual
KS064300G4-Ver1.1
- 5 -
16. Shaft
17. Power interface
18. PTZ master knob
19. PTZ chassis locking knob
20. Adjustment button of the
diffuse reflectance light
21. Adjustment button of the
coaxial light
22. Machine head gravity
adjustment screw
23. Articulated arm screw
24. Anti-slip fixing ring
Support rotation and tilt of the monitor.
Power supply to the monitor.
Loosen the knob to adjust the lens position. After
tightening the knob, the lens can be fixed at the
current position.
The pan/tilt can be rotated 180° horizontally after
loosening the knob。After tightening the knob, the
pan/tilt can be fixed at the current position.
Clockwise twist: turn on the diffuse reflectance
light/strengthen the diffuse reflectance lightness.
Anticlockwise twist: weaken the diffuse reflectance
lightness/turn off the diffuse reflectanc light.
Clockwise twist: turn on the coaxial light/
strengthen coaxial lightness. Anticlockwise twist:
weaken the coaxial lightness/turn off the coaxial
light.
Bearing range 0-8kg,Rotate 360 degrees in
“+”direction to increase the arm strength,Rotate
360 degrees in “-”direction to reduce the arm
strength。
Lock or adjust the articulated arm swing.
Prevent the bracket from slipping。

HD62 User Manual
KS064300G4-Ver1.1
- 6 -
3.2 Accessory Introduction
USB cable The digital microscope can be
powered by connecting to the
adapter.
HDMI cable
Power adapter
Wired
controller
(optional
accessories)
Connecting the digital microscope
to and monitor to achieve signal
transmission between
digital microscope and monitor.
Connect and supply power to the
monitor.
Connect to the monitor and
adjust its parameters.

HD62 User Manual
KS064300G4-Ver1.1
- 7 -
Chapter 4 Installation Guide
4.1 Methods of application of electron microscope
1. Assembly:
1) Screw out three screws on the round column with medium hex wrench ,Lock the bottom
plate and the round column, shown as image 1
2) Lock the articulating arm on the round column, shown as image 2.
3) Insert the square column with the monitor into the articulating arm, shown as image 3.
4) lock the two inner-hexagon screws with small L-shaped hex wrench , shown as image 4.
5) Screw 2 handles into the articulated arm ,shown as image 5.
0把 立上
Image 1 Image 2 Image 3 Image 4
2. Connections:
Image 5 Image 6 Image 7
3. Start to use:
1) Turn on the monitor, shown as image 8
2) Turn on the camera, shown as image 9
3) Adjust the focal length on the top of camera, shown as image 10
Image 8 Image 9 Image 10
1) Connect the camera to the monitor with HDMI and USB cables, shown as image 6, Connect
LED light to monitor with USB cable.
2) Power the monitor with the socket of AC 110-240V, shown as image 7

HD62 User Manual
KS064300G4-Ver1.1
- 8 -
Chapter 5 Digital camera Instructions
5.1 Instruction of manual focusing knob on the top of the
digital camera
1. Connect the relevant accessories such as digital microscope and monitor, etc. (For
detailed operation, please refer to Chapter 4)
2. Switch the toggle key to status of power on.
3. Rotate the manual focusing knob clockwise or anti-clockwise to adjust the eye height
until the image is clearly displayed.
(1) Clockwise: BFL gets shorter, object distance increases, magnification decreases.
(2) Anti-clockwise: BFL gets longer, object distance decreases, magnification
increases.
1. PTZ main knob
(1)counterclockwise rotation: Unscrew the knob
to steer freely.
(2)clockwise rotation: Lock the current position
of the lens.
5.2 Introduction of Rotatable ball head
Tabla de contenidos
Otros manuales de Microscopio de Lanoptik
Manuales populares de Microscopio de otras marcas

VWR
VWR VisiScope 384 Series Manual de usuario

Nikon
Nikon ECLIPSE E200 POL Manual de usuario

Leica
Leica DI C800 Manual

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manual de usuario

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manual de usuario

Olympus
Olympus SZ61 Manual de usuario

















