Kullhaus alpha Q20L Pro Manual de usuario

alpha Q20L Pro
alpha Q25L Pro
operating instructions

CONTENTS
Safety precautions .................................................................................................................3-4
Safety Regulations for Service and Repair Work..........................................................................5-6
Product Description.....................................................................................................................7
Technical Specications............................................................................................................... 8
Placement .............................................................................................................................. 8
Operating Instructions ...........................................................................................................9-14
Cleaning and Maintenance ..................................................................................................... 13
Trouble shooting........................................................................................................................14
Display Error Codes.................................................................................................................15
KULLSAVE ............................................................................................................................... 15
Storage ............................................................................................................................... 15
Smart Connection Operation Guide ..............................................................................16-19
Conditions of Warranty ......................................................................................................... 20
Thank you for choosing Kullhaus.
Please read instructions before using the dehumidier and keep it for future reference.
1

Only for home use / power source 220-240V/50Hz
Read the USER MANUAL carefully before operation.
This device is for home use only and not for commercial, industrial or outdoor use.
We reserve the right for any error in the text or images and any necessary changes
made to technical data.
Recycle unwanted materials instead of disposing of them. All appliances and packag-
ing should be sorted and tendered at a regional recycling centre and be processed in
an ecological manner.
This unit uses a ammable refrigerant.
If refrigerant leaks and comes in contact with re or heating part, it will create
harmful gas and there is risk of re.
Before putting the device into operation for the rst time, place it in an upright
position for at least 3 hours to stabilize the compressor uids.
Service personnel are required to carefully read the USER MANUAL and SERVICE
MANUAL before operation. Failure to abide by this warning could result in an explo-
sion, injury and property damage.
2

3
SAFETY INSTRUCTION
• Read the operating instructions carefully before using the dehumidier & keep it for future reference.
• To avoid electric shock, re or injury, please read the user manual carefully before using the appliance and keep it for future
reference.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
• The unit is designed only for use with R-290 (propane) gas as the designated refrigerant.
• THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT TO SERVICE!
• Do not discharge the refrigerant into the atmosphere.
• R-290 (propane) is ammable and heavier than air.
• It collects rst in low areas but can be circulated by the fans.
• If propane gas is present or even suspected, do not allow untrained personnel to attempt to nd the cause.
• The propane gas used in the unit has no odour.
• The lack of smell does not indicate a lack of escaped gas.
• If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local re department
to advise them that a propane leak has occurred.
• Do not let any persons back into the store until the qualied service technician has arrived and that technician advises that it
is safe to return to the store.
• No open ames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.
• Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced
with identical repair parts.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in
order to avoid a hazard.
• The appliance shall be disconnected from its power source during maintenance.
• Ensure the unit is far away from re, inammable, or explosive objects.
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.

4
SAFETY INSTRUCTION
The appliance shall be stored in a room without continuously operation sources (for example: open ames, an operating gas ap-
pliance or an operating electric heater).
The appliance shall be stored so as to prevent mechanical damage from occurring.
Do not piece or burn, even after use.
Pipework shall be protected from physical damage.
THE MACHINE MAY ONLY BE INSTALLED IN A ROOM WITH MINIMUM FLOOR AREA OF 4 m².
Compliance with national gas regulations shall be observed.
Keep any required ventilation openings clear of obstruction.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specied for opera-
tion.
Warning on Refrigerant R290
• Failure to abide by this warning could result in an explosion, death, injury and property damage.
• Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certicate from
an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance
with an industry, recognized assessment specication.
• Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of am-
mable refrigerants.

5
Repairs must only be carried out by authorised service personnel and only using genuine
spare parts. Please follow these warnings when servicing a dehumidier with R290.
Checks to the area
Prior to beginning work on systems containing ammable refrigerants, safety checks are necessary to ensure that the
risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a ammable gas or vapour being
present while the work is being performed.
General work area
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work
in conned spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions
within the area have been made safe by control of ammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is
aware of potentially ammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with
ammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
Presence of re extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re extinguishing
equipment shall be available to hand. Have a dry powder or CO² re extinguisher adjacent to the charging area.
No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or
has contained ammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of re
or explosion. All possible ignition sources, including cigarette smoking, should be kept sufciently far away from the site of
installation, repairing, removing and disposal, during which ammable refrigerant can possibly be released to the surround-
ing space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no
ammable hazards or ignition risks. “No Smoking” signs shall be displayed.
Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any
hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely
disperse any released refrigerant and preferably expel it externally into the atmosphere.
SAFETY REGULATIONS FOR SERVICE AND REPAIR WORK

6
SAFETY REGULATIONS FOR SERVICE AND REPAIR WORK
Checks to the refrigeration equipment
Where electrical components are being changed, they shall be t for the purpose and to the correct specication. At all
times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s tech-
nical department for assistance.
The following checks shall be applied to installations using ammable refrigerants:
– The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
– Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance
which may corrode refrigerant containing components, unless the components are constructed of materials which are
inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.
If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfacto-
rily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while charging, recovering or purging the system;
-that there is continuity of earth bonding.
Releasing refrigerant into atmosphere is strictly forbidden!

7
PRODUCT DESCRIPTION
CONTROL PANEL DESCRIPTION
Ionizer Indicator
Ionizer Indicator
Timer Indicator
Timer Indicator
Automatic Louver Indicator
Automatic Louver Indicator
UV Indicator
UV Indicator
Air Purifying Indicator
Air Purifying Indicator
Laundry Drying Indicator
Laundry Drying Indicator
Sleeping Indicator
Sleeping Indicator
Auto Indicator
Auto Indicator
Low Fan Speed Indicator
Low Fan Speed Indicator
High Fan Speed Indicator
High Fan Speed Indicator
Wi-Fi Indicator
Wi-Fi Indicator
Tank Full Indicator
Tank Full Indicator
Defrosting Indicator
Defrosting Indicator
Childlock Indicator
Childlock Indicator
1. Power Button
2. Timer Button/Childlock Button
3. Mode Button/Ionizer Button
4. Auto Button
5. Automatic Louver Button/UV Button
6. Fan Speed Button/WiFi Button (Optional)
7. Manual Button

TECHNICAL SPECIFICATIONS
The above technical data is for reference only. We reserve the right to modify them without notice.
Model alpha Q20L Pro alpha Q25L Pro
Power Supply 220-240V~ 50Hz 220-240V~ 50Hz
Dehumidifying Capacity
30°C 80% RH 20L/day 25L/day
27°C 60% RH. 12L/day 15L/day
Rated Power 245 watts / 1.73Α 290 watts / 1.63Α
Rated Current 1.73Α 1.63Α
Air Flow
High 190 m³/h 190 m³/h
Low 160 m³/h 160 m³/h
Noise Level
High 44 dB(A) 44 dB(A)
Low 40 dB(A) 42 dB(A)
Fan speeds 2 2
Water Tank Capacity 4.5L 4.5L
Operating Temperature 5°C~35°C 5°C~35°C
Timer 1−24 h 1−24 h
Refrigerant / Charge R290 / 0,068 kg R290 / 0,075 kg
Weight 15 kg 15.7 kg
Dimension (WxDxH) 378 x 273 x 580 mm 378 x 273 x 580 mm
PLACEMENT
Check the dehumidier for any transport damage. In case of damage, you should contact with seller immediately.
• Make sure that the dehumidier is standing rmly on a at surface
• Make sure that the mains lead is easily accessible and is not damaged by
sharp edges or is crushed in any way during use.
• If any part of your house suffers from severe humidity, the dehumidier can be
placed there rst and then moved to another part of the house later.
• Ensure the dehumidier is at a safe distance at least 50cm away from a wall or
furniture.
• Never place the dehumidier next to a radiator or heating appliance.
8

OPERATING INSTRUCTIONS
Note:
• Supply power should be in correspondence with the value on the nameplate, power outlet needs to be grounded.
• Do not use the device with power strip, as they may overheat and cause a re. However, if necessary, use a good
quality extension cord and rst make sure that it is in excellent condition.
• Ensure the tank is correctly tted, if the tank is full or not in place, the “Tank Full” indicator comes on and the dehu-
midier will stop working.
• If the dehumidier is turned off and then turned back on again immediately, it will take approximately 3 minutes to
reach full power (compressor back to work).
• If the dehumidier switched off by a power cut, it will automatically switch back on once the power is restored.
• The dehumidier works best at normal room temperature, its efciency is reduced if the ambient temperature falls to
below 15°C.
Connect the mains lead to socket. Press power button once to turn on the unit. By default, it runs on Manual Dehumidify-
ing Mode. Press Power button once again to turn off the unit.
Switching On/Off the Unit
At ON mode, press Timer button consecutively from 1-24h to select your preferred timer duration for automatic shutoff
setting. Its corresponding Timer indicator will be displayed on screen.
Timer Setting
Humidity Setting Control
Press Manual button once to enter Manual Dehumidifying Mode or to select desired level of humidity from CO-30%-35%-
40%-45%-50%-55%-60%-65%-70%-75%-80%-CO.
Note: if ambient humidity lower than 30%, display shows.
if ambient humidity higher than 90%, display shows.
Este manual sirve para los siguientes modelos