KRUUSE Trio Guía de instalación

MANUAL
RECEPTION + OPERATION + MAINTENANCE
www.kruuse.com
Printed in Canada

805-0260-035
2
TABLE
OF CONTENTS.
User Responsibility.............................................3
Standard and optional Features...........................4
Receiving, Assembly and Start-up....................6-10
Hanpieces pressure Adjustment..........................11
Assembled View.............................................12
Top Control Details..........................................13
Compressor Control Details...............................14
Compressor inside views..................................15
Daily Maintenance Procedure............................16
Warranty.......................................................18
KTQ052014V1

805-0260-035 3
USER
RESPONSIBILITY.
Read this manual before operating the equipment. Pay special attention to
all Warnings and Cautions.
This product will perform in conformity with the description contained in this
operating manual when assembled, operated, maintained and repaired in
accordance with the instructions provided. This product must be checked
periodically. A defective product should not be used. Parts that are broken,
missing, plainly worn, distorted or contaminated should be replaced
immediately. Should such repair or replacement become necessary,
Dispomed recommends that a telephone or written request for service be
made to the nearest Dispomed regional service center. This product, or any
of its parts should not be repaired other than in accordance with written
instructions provided by Dispomed and by Dispomed trained personnel.
The product must not be altered without the prior written approval of
Dispomed. The user of this product shall have the sole responsibility for any
malfunction which results from improper use, faulty maintenance, improper
repair, damage, or alteration by anyone other than a qualified Dispomed
technician.
Caution: This device is intended for use by veterinarians who are
thoroughly familiar with the use of such products. Do not attempt to use
this product if you have not previously been trained on the use of dental
delivery units.

805-0260-035
4
KRUUSE
DENTAL DELIVERY UNIT.
Standard features include:
• Air/water syringe
• 2 water bottles
• Independent water flow valves
• Handpiece guards
• Suction (Highdent Quattro)
• Shelf
Product dimensions:
• Length: 43.2 cm (17”)
• Width: 52.1 cm (20.5”)
• Min. height: 91.4 cm (36”)
• Max. height: 118.1 cm (46.5”)
• Weight: 49.9 kg (110 lbs)
Specifications:
• Amps: 2.2 A
• Power source: 230V AC,
• Operating frequency: 50Hz
• Operating temperature range : 15°C to 30°C
• Shelf max weight: 0.9 kg (2 lbs)
Optional features include:
• Grey + colors options
• NSK autoclavable Piezo scaler
• Fiber optic


805-0260-035
6
RECEIVING, ASSEMBLY AND START-UP
INSTRUCTIONS.
Your KRUUSE dental delivery unit requires some assembly before being
used.
Receiving
To keep the possibility of damage during shipment to a minimum, the
KRUUSE unit is shipped with its base strapped to a skid. All accessories are
included in a bag and or small box within the shipping crate.
Instructions
Caution: To avoid injury while removing the unit from the box always have
another person assist you.
Upon receipt and unpacking, inspect both the shipping container and all
of the enclosed components for signs of damage which may have occurred
during transit. Check your materials list to ensure that all the necessary
components are included.

805-0260-035
7
RECEIVING, ASSEMBLY AND START-UP
INSTRUCTIONS CONTINUED1.
1 2
3 4
Carefully open accessories bag and place pedal
on floor.
The syringe and suction can be interchanged
between the 2 holders on the left, if so equipped.
Install handpiece tubes to holders starting from the
right and following the order in which they are
connected to the bottom of the unit.
Fill water bottles with distilled water and install
under head of unit by inserting drive tubes and
screwing bottles into place. Screw the suction
bottle. Make sure the suction filter is in place.

805-0260-035 8
RECEIVING, ASSEMBLY AND START-UP
INSTRUCTIONS CONTINUED2.
5
Install handpieces from right to left:
1: Piezo
2: High speed (Optionnal)
3: Low speed (Optionnal)
(Caution: Never run handpiece without tip or Bur)
7
Connect power supply line on the back of head
assembly.
Plug unit into a 230V electrical outlet. (May not be
as illustrated)
6
1
2
3
8
Turn compressor on. (On units equipped with
compressor the switch is near the pressure gauge
at the left of the compressor).

805-0260-035
9
RECEIVING, ASSEMBLY AND START-UP
INSTRUCTIONS CONTINUED3.
11
If using another air source check for supply pressure
of approximately 5.5 bar (80 P.S.I.) at source.
Turn water valve on. (Top switch just below
rectangular handpiece pressure gauge).
109
The gauge should indicate approximately 5.5 bar
(80 P.S.I.) once compressor has stopped.
12
Test syringe by pressing air button then water
button than both simultaneously for mist.

805-0260-035 10
RECEIVING, ASSEMBLY AND START-UP
INSTRUCTIONS CONTINUED4.
13
Remove high speed handpiece from holder and
press pedal. Check for proper operation. Adjust
water flow to desired level. Replace handpiece in
holder.
Remove low speed handpiece from holder and
press pedal. Check for proper operation. Replace
handpiece in holder.
Remove Piezo from holder and press pedal. Check
for proper operation. Adjust water flow to desired
level. Adjust power according to tip being used.
See Tip guide. Replace handpiece in holder.
14
15
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Equipo dental de otras marcas

Vatech
Vatech EzRay Air VEX-P300 Manual de usuario

KaVo
KaVo GENTLEpower LUX Contra-angle 25 LP Manual de usuario

DENTSPLY
DENTSPLY SmartLite Focus Manual de usuario

LM
LM ProPower CombiLED Manual de usuario

Owandy Radiology
Owandy Radiology RX-AC Manual de usuario

mectron
mectron Piezosurgery Manual de usuario