Kongsberg K-Sync Especificaciones técnicas

KongsbergK-Sync
SynchronizingUnit
Productdescription
KongsbergMaritime
342385/B
March2010

Documenthistory
Documentnumber:342385
Rev.ADecember2009Firstversion.
Rev.BMarch2010Minorchanges–newpicture
Note
TheinformationcontainedinthisdocumentremainsthesolepropertyofKongsbergMaritimeAS.No
partofthisdocumentmaybecopiedorreproducedinanyformorbyanymeans,andtheinformation
containedwithinitisnottobecommunicatedtoathirdparty,withoutthepriorwrittenconsentof
KongsbergMaritimeAS.
KongsbergMaritimeASendeavourstoensurethatallinformationinthisdocumentiscorrectandfairly
stated,butdoesnotacceptliabilityforanyerrorsoromissions.
Warning
Theequipmenttowhichthismanualappliesmustonlybeusedforthepurposeforwhichitwas
designed.Improperuseormaintenancemaycausedamagetotheequipmentand/orinjurytopersonnel.
Theusermustbefamiliarwiththecontentsoftheappropriatemanualsbeforeattemptingtooperate
orworkontheequipment.
KongsbergMaritimedisclaimsanyresponsibilityfordamageorinjurycausedbyimproperinstallation,
useormaintenanceoftheequipment.
Comments
Toassistusinmakingimprovementstotheproductandtothismanual,wewelcomecommentsand
constructivecriticism.
e-mail:[email protected]
Stra n dprom e n a de n 5 0
P.O.Box 1 11
N- 31 91 H orte n ,
No rwa y
Ko n g s b e r g M a r it im e A S
Te leph one : + 47 3 3 0 2 3 8 0 0
Te lefa x: + 47 3 3 0 4 4 7 5 3
s ub se a @ko ng sb e rg .com
w w w .k o n g s b e r g .c o m

Productdescription
Tableofcontents
1SYSTEMOVERVIEW..........................................................5
2TRIGGERGROUPS.............................................................7
2.1Triggerdisplay.........................................................................................................8
3ECHOSOUNDERSTATUS.................................................10
3.1Enable/disableechosounder..................................................................................10
4DIAGNOSTICTOOL.........................................................11
5TECHNICALSPECIFICATIONS.........................................12
6DRAWINGS.....................................................................13
342385/B3

KongsbergK-Sync
4342385/B

Systemoverview
1SYSTEMOVERVIEW
TheSynchronizingUnitschedulestheechosounderstotransmit
accordingtotriggergroups.Thereareatotalof16triggergroups
andanynumberofechosounderscanbeassignedtoagroup
(zeroormore).Eachgroupistriggeredconsecutively,whilethe
echosoundersassignedtoagrouparetriggeredatthesametime.
Onceitisdetermined(byreadingfeedbacksignals)orestimated
(basedonusersettings)thatallechosoundersinthecurrent
grouphavecompletedtheirpingcycle,thenthenextgroupis
triggered.Allgroupsaretriggeredinround-robinfashion.The
durationofeachgroupisnotxedanddependsuponwhatthe
maximumactiveperiodisfortheechosoundersinthatgroup.
Echosounderscanbetakenoutoftheschedulewithoutchanging
thegroupschedule,bysimplydisablingit.Ifagroupdoesnot
containanyavailableechosounders,thenthatgroupisskipped.
TheSynchronizingUnitsystemconsistsoftwomaincomponents:
•AWorkstationPCrunningtheSynchronizingUnit(SU)
application.
•ASynchronizingUnitthatinterfaceswiththeechosounders.
Figure1SystemOverview
TheSynchronizingUnitapplicationprovidestheuserinterface,
whichallowsmonitoringofstatus,modifyingsettings,trigger
scheduleaswellasperformingdiagnostics.Theapplication
needstorunandbeconnectedtotheSynchronizingUnitinorder
forthesystemtoinitializeandbeoperational.However,once
thesystemisrunning,theapplicationcanbeshutdownand
disconnectedcompletelywhiletheSynchronizingUnitcontinues
tocontrolthetriggeringofechosounders.
342385/B5

KongsbergK-Sync
TheSynchronizingUnitcontrolspingingandreceivesstatus
fromtheechosoundersviathesignalinterface.Atriggeroutput
isprovidedforeachechosounderaswellasinputsforreceiving
feedbacksignalsfromechosounders.Feedbacksignalsarenot
required,butwillbeusedwhenavailable.Iffeedbacksignalsare
notavailable,theSynchronizingUnitcanestimatetheperiod
requiredfortheechosoundertobecomeready.
6342385/B

Triggergroups
2TRIGGERGROUPS
Thetriggergroupsarethebasisfortheschedulingoftheecho
sounders.TheSynchronizingUnitusestheruntimeparameters
todeterminetheindividualtimingoftheechosounders,while
thetriggergroupsspecifyinwhatorderandwhichechosounders
willtransmittogether.
Thedisplayconsistsoftwoparts:
1Activegroupindicator(seeFig.Triggerstatusonpage7).
2Triggerschedule.
Theactivegroupindicatorshowswhichgroupiscurrentlyactive.
Groupsthatdonothaveanyechosoundersassignedtothemare
skipped.Amaximumof16groupscanbescheduled.Sinceeach
echosounderhasdifferenttimingrequirements,thedurationof
eachgroupwilldependuponwhichechosoundersareassigned
tothegroup(i.e.longestactiveperiodoftheechosounders).
Figure2Triggerstatus
Triggerstatusshowswhichisthecurrentgroupandwhichgroup
eachechosounderisassignedto
Thetriggerscheduleshowsonesystemperrow,andthetrigger
groupsareshownacross.AgreenLEDdesignatesthattheecho
sounderhasbeenassignedtothatgroup.Tomodifytheschedule,
clickcongure.Andcheckthegroupsthatanechosounder
shouldbeassignedto(seeFig.Triggergroupsonpage8).
342385/B7

KongsbergK-Sync
Figure3Triggergroups
Triggergroupcongurationdialogueallowsusertoassignecho
sounderstotriggergroups
2.1Triggerdisplay
Thetriggerdisplayisareal-timedisplaythatshowsthecurrent
stateofeachechosounderplottedacrosstime.Therearetwo
plotsforeachechosounder:
1Triggerplot
2Stateplot
ThetriggerplotshowsapulsewhenevertheSynchronizingUnit
istriggeringtheechosounder.Thislineisblue.
Thestateplotshowsthecurrentstatebasedonschedulingand
feedbacksignalsandisconveyedbyitscolour.
Table1Interpretationoftriggerdisplayplots
Gray
line
Echosounderhasbeendisabledby
operatorortheechosounderisinStandby
state(i.e.timedout/notready)
Green
line
Echosounderisreadytobetriggered
RedlineEchosounderiscurrentlytransmitting,
receivingand/orprocessingsamples(i.e.
notready)
State
plot
Red
pulse
Echosounderacknowledgedthata
transmitoccurred(widthofpulseisalways
constant)
Trigger
plot
Blue
pulse
Triggerpulse
Eachtriggergroupisvisuallyseparatedbytheverticalgroup
lineinyellow.
Byinspectingthetriggerchartforaparticulargroupitispossible
toseewhichechosounderistakingthelongesttocompletethe
pingcycle.Thisechosounderwillhavearedlinethatstartsat
thebeginningandextendsallthewaytotheendofthegroup.
8342385/B

Triggergroups
Figure4OS38–Echosounder
Thisplotshowsanechosounder,OS38,whichhasthelongest
periodinthegroupandconsequentlydeterminestheoverallping
rateforthegroupsitisassignedto.
342385/B9

KongsbergK-Sync
3ECHOSOUNDERSTATUS
TheindividualstatesoftheechosoundersareshownintheEcho
sounderstatusdisplay.Foreachechosounderthereisalsoa
checkboxforenablinganddisablingthesystem.
Figure5EchoSounderStatus
TheEchosounderstatusprovidessynchronizingstatusforeach
oftheinstalledechosounders
3.1Enable/disableechosounder
Evenifanechosounderisscheduled,itcanbeoverriddenby
enable/disablesetting.Ifenabled(checked)itwillbetriggered
accordingtotheschedule,ifdisabled(unchecked)itwillnotbe
triggeredevenifscheduled.Thissettingisseeninthecheck
boxonthelefthandsideoftheEchosounderstatusareaofthe
userinterface.
10342385/B
Otros manuales para K-Sync
2
Tabla de contenidos
Otros manuales de Equipo de grabación de Kongsberg
Manuales populares de Equipo de grabación de otras marcas

Strymon
Strymon NIGHTSKY Manual de usuario

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manual de usuario

Tews Technologies
Tews Technologies TPMC465 Manual de usuario

Honeywell
Honeywell Excel 50 Manual de usuario

SeaLevel
SeaLevel COMM+8.LPCI Manual de usuario

Arturia
Arturia AUDIOFUSE STUDIO Manual de usuario