Klimaire ksie series Manual de usuario

Thank you very much for purchasing our products.
Please read this manual carefully before using the
remote controller.
AIR CONDITIONER
REMOTE CONTROLLER ILLUSTRATION
SERIES

1
CONTENTS
NOTE:
Buttons design is based on typical model and might be slightly different from the
actual one you purchased,the actual shape shall prevail.
All the functions described are accomplished by the unit. If the unit has no this
feature, there is no corresponding operation happened when press the relative
button on the remote controller.
When there are wide differences between Remote controller Illustration and
USER'S MANUAL on function description, the description of USER'S MANUAL
shall prevail.
,,
,, ,,
,, ,,
,,
2
3
6
7
7
7
8
9
13
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Operation buttons .................. .........................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Timer operation...............................................................................

2
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03×2)
RG57A6/BGEFU1
Remote Controller Specifications
Environment
Signal Receiving
Range
MODE
FAN
TEMP
SLEEP
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
O O
23 F~140 F

3
MODE
FAN
TEMP
SLEEP
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
4
3
8
9
7
5
6
10
12
11
13
14
1
2
Press this button to modify the air conditioner
mode in a sequence of following:
3
MODE Button
4
5
ON/OFF Button
This button turns the air conditioner ON
and OFF.
AUTO
COOL
DRY
HEAT FAN
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
FAN Button
SLEEP Button
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, FAN
SPEED or ON/OFF button is pressed.
Active/Disable sleep function. It can
maintain the most comfortable temperature
and save energy. This function is available
on COOL, HEAT or AUTO mode only .
For the detail, see sleep operation in
USER S MANUAL.
,
,, ,,
,,
,,
NOTE:Please do not select HEAT mode if the
machine you purchased is cooling only type.
Heat mode is not supported by the cooling only
appliance.
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
SELF CLEAN Button
Active/Disable Self Clean function.
Under SELF CLEAN mode, the air
conditioner will automatically clean and dry
the Evaporator and keep it as fresh for the
next operation.
Operation of buttons
6
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temper-
ature at cooling or heating operation in the
shortest time(if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN

4
MODE
FAN
TEMP
SLEEP
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
4
3
8
9
7
5
6
10
12
11
13
14
TIMER ON Button
7
9
8
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the auto-
timed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
Operation of buttons
SWING DIRECT
,
,
,
,
,
SILENCE/FP Button
Active/Disable SILENCE function. If pushing
more than 2 seconds, the FP function will
be activated, pushing more than 2 seconds
again to disable.
When the Silence function is activated, the
compressor will operate at low frequency
and the indoor unit will bring faint breeze,
which will reduce the noise to the lowest
level and creat a quiet and comfortable room
for you. Due to low frequency operation of
compressor, it may result in insufficient
cooling and heating capacity.
The FP function can only be activated
during the heating operation(only when the
setting mode is HEAT). The unit will operate
O
at a setting temperature of 46 F.The display
window of indoor unit will display FP .Press
the buttons of ON/OFF, SLEEP, FP, MODE,
FAN SPEED,UP or DOWN while operating
will cancel the FP function.
,
,
,
LED FOLLOW
ME
TURBO SELF
CLEAN
UP Button( )
Push this button to decrease the indoor
o o
temperature setting in 1F increments to 62F.
DOWN Button( )
Push this button to increase the indoor
o o
temperature setting in 1F increments to 86F.
NOTE:Temperature contol is not available
in Fan mode.
NOTE: Press and hold UP and DOWN buttons
together for 3 seconds will alternate the temper-
O O
ature display between the C & F scale.

11
12
14
13
FOLLOW ME Button
Push this button to initiate the Follow Me
feature, the remote display is actual
temperature at its location. The remote
control will send this signal to the air
conditioner every 3 minutes interval until
press the Follow Me button again. The air
conditioner will cancel the Follow Me feature
automatically if it does not receive the signal
during any 7 minutes interval.
Operation of buttons
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.
5
SWING Button
DIRECT Button
Used to change the louver movement and set
the desired up/down air flow direction.
O
The louver changes 6 in angle for each press.
Used to stop or start horizontal louver auto
swing feature.
MODE
FAN
TEMP
SLEEP
ON/OFF
SILENCE
FP
TIMER
ON
TIMER
OFF
1
2
4
3
8
9
7
5
6
10
12
11
13
14
SWING DIRECT
LED FOLLOW
ME
TURBO SELF
CLEAN
TIMER OFF Button
10
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the auto-
timed program, simply adjust the auto-off
time to 0.0

Indicators on LCD
Fan speed indication
Mode display
Information are displayed when
the remote controller is powered
up.
Displayed when data transmitted.
Displayed when remote controller is ON.
Battery display(low battery detection)
Not available for this unit
Not available for this unit
Low speed
Medium speed
High speed
Auto fan speed
Note:
of clear presentation. But during the actual operation
only the relative functional signs are shown on the
display window.
All indicators shown in the figure are for the purpose
Displayed when TIMER ON time is set.
Displayed in Sleep Mode operation.
Indicated that the air conditioner is
operating in Follow me mode
Not available for this unit
Displayed when TIMER OFF time is set.
Show set temperature or room
temperature, or time under TIMER
setting.
AUTO
HEAT FAN
COOL DRY
6

How to use the buttons
Cooling /Heating/Fan operation
Ensure the unit is plugged in and power is
available.
1. Press the MODE button to select COOL,
HEAT(cooling & heating models only) or
FAN mode.
2. Press the UP/DOWN buttons to set the
desired temperature. The temperature can
O O O
be set within a range of 62 F~ 86 F in 1 F
increments.
3. Press the FAN button to select the fan speed
in four steps- Auto, Low, Med,or High.
4. Press the ON/OFF button to start the air
conditioner.
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.
NOTE
Auto operation
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select Auto.
2. Press the UP/DOWN button to set the
desired temperature. The temperature can
O O O
be set within a range of 62 F~ 86 F in 1 F
increments.
3. Press the ON/OFFbutton to start the air
conditioner.
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
MODE
FAN
TEMP
ON/OFF
TIMER
ON
TIMER
OFF
4
1
3
2
MODE
FAN
TEMP
ON/OFF
SILENCE
FP
SILENCE
FP
TIMER
ON
TIMER
OFF
3
1
2
7
LED FOLLOW
ME
LED FOLLOW
ME
TURBO SELF
CLEAN
TURBO SELF
CLEAN
SWING DIRECT
SWING DIRECT
SLEEP
SLEEP

SILENCE
FP
Dehumidifying operation
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the MODE button to select DRY mode.
2. Press the UP/DOWN buttons to set the
desired temperature. The temperature
O O
can be set within a range of 62 F~ 86 F in
O
1 F increments.
3. Press the ON/OFF button to start the air
conditioner.
In the Dehumidifying mode, you can not switch the
fan speed. It has already been automatically controlled.
NOTE
MODE
FAN
TEMP
ON/OFF
TIMER
ON
TIMER
OFF
3
1
2
How to use the buttons
8
LED FOLLOW
ME
TURBO SELF
CLEAN
SWING DIRECT
SLEEP

2
1
Timer operation
Press the TIMER ON button can set the auto-on
time of the unit. Press the TIMER OFF button
can set the auto-off time of the unit.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases by half an hour between 0
and 10 hours and by one hour between 10 and
24 hours.
3. After setting the TIMER ON ,there will be a one
second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set
desired Auto-off time. Each time you press the
button, the time increases by half an hour
between 0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a
one second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "H " will disappear and the set temperature
will re-appear on the LCD display window.
MODE
FAN
TEMP
ON/OFF
TIMER
ON
TIMER
OFF
9
SILENCE
FP
LED FOLLOW
ME
TURBO SELF
CLEAN
SWING DIRECT
SLEEP
Otros manuales para ksie series
2
Tabla de contenidos
Otros manuales de Mando a distancia de Klimaire

Klimaire
Klimaire KSIX Series Manual de usuario

Klimaire
Klimaire KUMR-903 Manual de usuario

Klimaire
Klimaire RG57A6/BGEFU1 Manual de usuario

Klimaire
Klimaire Kluf Series Manual de usuario

Klimaire
Klimaire KSIH Series Manual de usuario

Klimaire
Klimaire KSIN Series Manual de usuario

Klimaire
Klimaire KSID series Manual de usuario